STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF SACUBITRIL AND VALSARTAN IN BULK AND COMBINED PHARMACEUTICAL DOSAGE FORM

Author(s):  
Muqhtar Ahmed
Author(s):  
Dhiraj Kumar ◽  
Susanta Kumar Panda ◽  
Sudhir Kumar Sahoo

A precise, accurate, economical and simple stability indicating RP-HPLC method was developed for the estimation of Amlodipine (AML) and Olmesartan (OLM) in bulk and pharmaceutical dosage form. Method was performed on a octadecyl silane column with dimensions 4.6 x 250 mm having particle size 5 micron. The mobile phase used in the method is TEA Buffer (pH 3.0) and acetonitrile in proportion of 25:75 respectively. The flow rate was maintained at 1.0 ml/ min and effluent was monitored at 258 nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The retention times were observed at 2.39 min and 3.33 min for AML and OLM respectively. The standard curve was found linear over a range of 05–35 μg/ml for AML and OLM. Similarly an average correlation coefficient was also obtained at 0.999 for AML and OLM. The limit of quantitation (LOQ) of this method was 2μg/ml for Amlodipine and Olmesartan. The absolute recovery was 100% for Amlodipine and 100.3 for Olmesartan. Degradation products produced as a result of stress studies did not interfere with the detection of AML and OLM and the assay can thus be considered stability-indicating.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (09) ◽  
pp. 53-59
Author(s):  
Girija Dandu ◽  
Basu Venkateswara Reddy

The present study describes the development and validation of a new stability indicating RP-HPLC method for simultaneous estimation of elbasvir and grazoprevir in bulk and pharmaceutical dosage form. The chromatographic separation was done by using reverse phase YMC column (4.6 x 250mm, 5μm).The mobile phase used was mixture of HPLC grade water acetonitrile (70:30V/V) at flow rate of 1ml/ min in isocratic mode and detection was carried out using PDA detector at 244nm.The developed method showed a good linearity in the range of 100-500μg/mL for elbasvir and 200-1000 μg/mL for grazoprevir with regression co-efficient of 0.999 for both the drugs. The % recovery of drugs was found to be 100.1% for elbasvir and 100.38% for grazoprevir. The proposed stability indicating method was accurate, precise, robust, stable and specific. The developed method was validated in accordance with ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document