scholarly journals Transcatheter aortic valve replacement in patients with bicuspid aortic valves

2018 ◽  
Vol 10 (S30) ◽  
pp. S3568-S3572 ◽  
Author(s):  
Amisha Patel ◽  
Martin B. Leon
2020 ◽  
Vol 75 (11) ◽  
pp. 1251
Author(s):  
Adamantios Tsangaris ◽  
Chris Reiff ◽  
Alexandra Hall ◽  
Ganesh Raveendran ◽  
Rosemary Kelly ◽  
...  

2018 ◽  
Vol 33 (9) ◽  
pp. 489-496 ◽  
Author(s):  
Seyed Hossein Aalaei-Andabili ◽  
Thomas M. Beaver ◽  
John W. Petersen ◽  
R David Anderson ◽  
Ashkan Karimi ◽  
...  

2020 ◽  
Vol 41 (29) ◽  
pp. 2747-2755 ◽  
Author(s):  
Sameer A Hirji ◽  
Edward D Percy ◽  
Cheryl K Zogg ◽  
Alexandra Malarczyk ◽  
Morgan T Harloff ◽  
...  

Abstract Aims We sought to perform a head-to-head comparison of contemporary 30-day outcomes and readmissions between valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) patients and a matched cohort of high-risk reoperative surgical aortic valve replacement (re-SAVR) patients using a large, multicentre, national database. Methods and results We utilized the nationally weighted 2012–16 National Readmission Database claims to identify all US adult patients with degenerated bioprosthetic aortic valves who underwent either VIV-TAVR (n = 3443) or isolated re-SAVR (n = 3372). Thirty-day outcomes were compared using multivariate analysis and propensity score matching (1:1). Unadjusted, VIV-TAVR patients had significantly lower 30-day mortality (2.7% vs. 5.0%), 30-day morbidity (66.4% vs. 79%), and rates of major bleeding (35.8% vs. 50%). On multivariable analysis, re-SAVR was a significant risk factor for both 30-day mortality [adjusted odds ratio (aOR) of VIV-SAVR (vs. re-SAVR) 0.48, 95% confidence interval (CI) 0.28–0.81] and 30-day morbidity [aOR for VIV-TAVR (vs. re-SAVR) 0.54, 95% CI 0.43–0.68]. After matching (n = 2181 matched pairs), VIV-TAVR was associated with lower odds of 30-day mortality (OR 0.41, 95% CI 0.23–0.74), 30-day morbidity (OR 0.53, 95% CI 0.43–0.72), and major bleeding (OR 0.66, 95% CI 0.51–0.85). Valve-in-valve TAVR was also associated with shorter length of stay (median savings of 2 days, 95% CI 1.3–2.7) and higher odds of routine home discharges (OR 2.11, 95% CI 1.61–2.78) compared to re-SAVR. Conclusion In this large, nationwide study of matched high-risk patients with degenerated bioprosthetic aortic valves, VIV-TAVR appears to confer an advantage over re-SAVR in terms of 30-day mortality, morbidity, and bleeding complications. Further studies are warranted to benchmark in low- and intermediate-risk patients and to adequately assess longer-term efficacy.


Sign in / Sign up

Export Citation Format

Share Document