scholarly journals Intraocular pressure changes following the use of silicone oil or Densiron® 68 as endotamponade in pars plana vitrectomy

2010 ◽  
pp. 1391 ◽  
Author(s):  
Romano ◽  
Angi ◽  
Romano ◽  
Parmeggiani ◽  
Campa ◽  
...  
2011 ◽  
Vol 90 (8) ◽  
pp. 744-749 ◽  
Author(s):  
Carsten Framme ◽  
Susanne Klotz ◽  
Ute E.K. Wolf-Schnurrbusch ◽  
Peter Wiedemann ◽  
Sebastian Wolf

2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Erkan Ünsal ◽  
Kadir Eltutar ◽  
Belma Karini ◽  
Osman Kızılay

Objective. To evaluate the morphological changes of the anterior segment using ultrasonic biomicroscopy (UBM) imaging in pseudophakic patients who underwent pars plana vitrectomy (PPV) with silicone oil or gas (C3F8) internal tamponade agent injection.Method. This prospective study included pseudophakic patients with planned PPV, divided into two groups according to internal tamponade agent: those in which silicone oil was used (n=27, Group 1) and those in which gas (C3F8) was used (n=24, Group 2). UBM measurements were performed in the supine position before and one week after surgery.Results. In patients of Group 1, postoperative trabecular meshwork-ciliary process distance (T-CPD) and iris-ciliary process distance (I-CPD), according to preoperative values, were found to be statistically significantly reduced, and postoperative mean value of scleral thickness (ST) and intraocular pressure (IOP), according to preoperative value, was found to be statistically significantly increased. In patients of Group 2, postoperative mean values of anterior chamber depth (ACD), ciliary body thickness (CBT), T-CPD, I-CPD, and IOP, according to preoperative values, were found to be statistically significantly reduced. Preoperatively, in Group 2 patients, according to Group 1 patients, TIA and IOP were found to be statistically significantly increased. Preoperative and postoperative IOP between the measured parameters with UBM showed no statistically significant correlation.Conclusions. Gases cause more morphological changes in the anterior segment structures. It is thought that complications such as increased intraocular pressure can be seen more frequently for this reason.


2021 ◽  
Author(s):  
Xiaoyan Zhang ◽  
Xiaofeng Hao ◽  
Like Xie

Abstract Background: We investigated the incidence of and risk factors for intraocular pressure elevation within 6 days following pars plana vitrectomy with silicone oil injection for rhegmatogenous retinal detachment. Methods: We reviewed the records of 55 patients in whom pars plana vitrectomy with silicone oil injection was performed. The intraocular pressure was evaluated before surgery and 1 day, 3 days, and 6 days post-operatively. Results: Intraocular pressure elevation was found in 49% of eyes within 6 days after surgery. A long duration of rhegmatogenous retinal detachment was significantly associated with intraocular pressure elevation on day 1 after surgery. Presence of diabetes was significantly associated with intraocular pressure elevation at 3 days post-operation. Intraocular pressure elevation may occur 6 days following topical steroid use. Conclusions: Intraocular pressure should be monitored regularly in the early post-operative period after pars plana vitrectomy with silicone oil injection for rhegmatogenous retinal detachment, especially in patients with prolonged detachment and diabetic history.


2020 ◽  
Vol 32 (4) ◽  
pp. 335
Author(s):  
Touka Banaee ◽  
Arash Omidtabrizi ◽  
Vahid Ghavami ◽  
Masoud Shafiee ◽  
Razieh Bayani

Author(s):  
Tomasz K. Wilczyński ◽  
Alfred Niewiem ◽  
Rafał Leszczyński ◽  
Katarzyna Michalska-Małecka

A 36-year-old patient presented to the hospital with recurrent dislocation of the intraocular lens (IOL). The patient with the diagnosis of familial ectopia lentis was first operated on for crystalline lens subluxation in the left eye in 2007 and in the right eye in 2009. In both eyes, lens extraction with anterior vitrectomy and transscleral fixation of a rigid IOL was performed. In 2011, the IOL in the right eye luxated into the vitreous cavity due to ocular trauma. The patient underwent a pars plana vitrectomy with the IOL resuturation to the sclera. Seven years later, a spontaneous vision loss in the right eye was caused by a retinal detachment. The pars plana vitrectomy with silicone oil tamponade and a consequential oil removal three months later were performed in 2018. The follow-up examination revealed recurrent IOL dislocation in the same eye. Due to a history of previous suture-related complications a decision was made to remove the subluxated rigid polymethyl-methacrylate (PMMA) IOL and fixate to sclera a sutureless SOLEKO FIL SSF Carlevale lens. The purpose of this report is to present a single case of a 36-year-old patient who was presented to the hospital with recurrent dislocation of the intraocular lens. In a three-month follow-up period, a good anatomical and functional outcome was finally obtained with transscleral sutureless intraocular lens. This lens is an option worth considering especially in a young patient with a long life expectancy and physically active.


2021 ◽  
pp. 1-4
Author(s):  
Lorane Bechet ◽  
Raphaël Atia ◽  
Christina Zeitz ◽  
Saddek Mohand-Saïd ◽  
José-Alain Sahel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document