Spectrophotometric Method for Determination of Eltrombopag in Bulk and Pharmaceutical Formulation

Author(s):  
RUAA MUAYAD MAHMOOD ◽  
HAMSA MUNAM YASSEN ◽  
SAMAR , NAJWA ISSAC ABDULLA AHMED DARWEESH ◽  
NAJWA ISSAC ABDULLA

Simple, rapid and sensitive extractive spectrophotometric method is presented for the determination of glibenclamide (Glb) based on the formation of ion-pair complex between the Glb and anionic dye, methyl orange (MO) at pH 4. The yellow colored complex formed was quantitatively extracted into dichloromethane and measured at 426 nm. The colored product obeyed Beer’s law in the concentration range of (0.5-40) μg.ml-1. The value of molar absorptivity obtained from Beer’s data was found to be 31122 L.mol-1.cm-1, Sandell’s sensitivity value was calculated to be 0.0159 μg.cm-2, while the limits of detection (LOD) and quantification (LOQ) were found to be 0.1086 and 0.3292 μg.ml-1, respectively. The stoichiometry of the complex created between the Glb and MO was 1:1 as determined via Job’s method of continuous variation and mole ratio method. The method was successfully applied for the analysis of pharmaceutical formulation.


2013 ◽  
Vol 6 (1) ◽  
pp. 133-141 ◽  
Author(s):  
S. Binte Amir ◽  
M. A. Hossain ◽  
M. A. Mazid

The present study was undertaken to develop and validate a simple, sensitive, accurate, precise and reproducible UV spectrophotometric method for cefuroxime axetil using methanol as solvent. In this method the simple UV spectrum of cefuroxime axetil in methanol was obtained which exhibits absorption maxima (?max) at 278 nm. The quantitative determination of the drug was carried out at 278 nm and Beer’s law was obeyed in the range of (0.80-3.60) µg/ml. The proposed method was applied to pharmaceutical formulation and percent amount of drug estimated (95.6% and 96%) was found in good agreement with the label claim. The developed method was successfully validated with respect to linearity, specificity, accuracy and precision. The method was shown linear in the mentioned concentrations having line equation y = 0.05x + 0.048 with correlation coefficient of 0.995. The recovery values for cefuroxime axetil ranged from 99.85-100.05. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviations of inter-day precision ranged between 1.45-1.92% and intra-day precision of cefuroxime axetil was 0.96-1.51%. Hence, proposed method was precise, accurate and cost effective.  Keywords: UV-Vis spectrophotometer; Method validation; Cefuroxime axetil; Recovery studies.  © 2013 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.   doi: http://dx.doi.org/10.3329/jsr.v6i1.14879 J. Sci. Res. 6 (1), 133-141 (2013)  


Author(s):  
Saravanan Devarajan ◽  
Gobinath Manavalan ◽  
Kumar Balasubramanian ◽  
Jayakumar Annamalai ◽  
Narasimhakumar Madduri

2014 ◽  
Vol 50 (3) ◽  
pp. 457-465 ◽  
Author(s):  
Edith Cristina Laignier Cazedey ◽  
Hérida Regina Nunes Salgado

New, simple and cost effective UV-spectrophotometric method was developed for the estimation of orbifloxacin in pharmaceutical formulation. Orbifloxacin was estimated at 290 nm in 0.5 M hydrochloric acid. Linearity range was found to be 1.0-6.0 μg mL-1. The method was tested and validated for various parameters according to main guidelines. The proposed method was successfully applied for the determination of orbifloxacin in tablets. The results demonstrated that the procedure is accurate, precise and reproducible, while being simple, economical and less time consuming. It can be suitably applied for the estimation of orbifloxacin in routine quality control and dissolution studies.