scholarly journals THE RESULTS OF TOTAL HIP JOINT ENDOPROSTHESIS FOR CONGENITAL HIP DISLOCATION

2017 ◽  
Vol 19 (4) ◽  
pp. 524-527
Author(s):  
Jafar Safarov ◽  
2007 ◽  
Vol 40 ◽  
pp. S558 ◽  
Author(s):  
V. Fuis ◽  
T. Návrat ◽  
P. Hlavon ◽  
M. Koukal ◽  
M. Houfek

2020 ◽  
Vol 8 (2) ◽  
pp. 119-128
Author(s):  
Alexandr I. Avdeev ◽  
Igor A. Voronkevich ◽  
Dmitrii G. Parfeev ◽  
Anton N. Kovalenko ◽  
David G. Pliev ◽  
...  

Background. Conservative treatment options for hip dysplasia and hip dislocation in early childhood allow for good results in cases of a timely diagnosis. The preferred treatment option for patients with hip dislocation in adulthood is total hip joint replacement. The shortening osteotomy, proposed by T. Paavilainen, allows the surgeon to restore the difference in the lengths of the lower extremities during arthroplasty of the hip joint. However, according to the results of the Paavilainen technique, as presented by Russian orthopedic surgeons, the problem of nonunion of the greater trochanter fragment with the diaphysis of the femur remains unresolved, as evidenced by a massive group of clinical cases. Aim. The aim of this study was to identify factors affecting the consolidation of bone fragments after osteotomy of the greater trochanter, according to T. Paavilainen, during total hip arthroplasty and evaluate their significance after fixation with cerclage screws in comparison with a special trochanteric fork-plate. Materials and methods. The present study includes 208 cases that were treated at the Russian Scientific Research Institute of Traumatology and Orthopedics named after R.R. Vreden from 2003 to 2019 using various fixation techniques of the greater trochanter fragment. Patients were divided into two groups depending on their type of fixation. The quality of consolidation of a greater trochanter fragment with the femur was assessed during a follow-up period of six months or longer. The fragment of the greater trochanter was divided into the part that was not in contact with the diaphysis, or A, and the part that was in contact with the diaphysis, or B. We assessed the effect of the absolute value of the contact between fragments, the B/A ratio, the distance between the points of insertion of the screws into the diaphyseal part of the femur, the quality of the bone by the modified Barnet-Nordin index, and the history of previous surgical interventions on this joint on the consolidation. Results. When the part of the greater trochanter was in contact with the diaphysis of the femur (B) was less than 3.5 cm, the risk ratio of nonunion of the greater trochanter fragment with the diaphysis of the femur increased. Also, a significant factor is the index of the contact of the greater trochanter fragment (B/A less than 1) with the diaphysis of the femur using the T. Paavilainen technique. In addition, the presence of surgical intervention in the hip joint history significantly increases the relative risk (RR) of nonunion of the greater trochanter fragment with the diaphysis of the femur with this method of shortening osteotomy of the femur. Conclusion. In the absence of timely diagnosis and conservative treatment of children with hip dislocation, reconstructive-plastic techniques on the hip joint do not allow the achievement of proper results and increase the complexity of total hip arthroplasty. According to the results of this study, the absolute value of the contact between fragments (B), the index of the greater trochanter contact with the diaphysis of the femur, and the history of previous surgical intervention on this joint are objective tools for the prognostic assessment of the probability of fragment unions during total hip arthroplasty with the T. Paavilainen technique.


2021 ◽  
Vol 07 (10) ◽  
Author(s):  
Khojaakhmed Shaykhislamovich Alpysbaev ◽  

The immediate results of treatment of 72 children aged 7 to 12 years with aseptic necrosis of the femoral head after bloodless reduction of congenital hip dislocation were analyzed. When treating patients, the following types of surgical treatment were used:extra-articular or open centering of the femoral head with intertrochanteric-torsion-varizing or devarizing and rotational osteotomy of the femur with bringing down the greater trochanter in the caudal direction. In all patients, pain and lameness disappeared, internal rotation of the lower extremities when walking, and the range of motion in the hip joint improved. Improved radiometric parameters characterizing the ratio of the acetabulum and the head of the femur and the angular values of the hip joint and proximal femur.


Author(s):  
Myron Czerniec ◽  
Jarosław Zubrzycki

Total hip arthroplasty is a complex procedure. The achievements of implantology enabled the development of a faithful representation of hip joint physiology as well as the production of materials that can successfully replace damaged natural tissues. A very important issue is the correct selection of the geometry of the endoprosthesis adequate to the load of the joint. Materials used for endoprosthesis are a metal head and a polymer cup (e.g. PE-UHMW). The main interactions in the endoprosthesis are friction and surface pressure, which must be limited, exceeding them causes the destruction of the biomechanical system - plastic deformation of the polymer and the formation of too large and unacceptable radial clearances. Based on the author's developed calculation method of hip joint endoprosthesis contact parameters, the impact on maximum contact pressure and the angle of contact of the joint load was estimated depending on the diameter of the endoprosthesis and radial clearance. The correctness of changing the values of maximum contact pressure from the mentioned parameters was determined. Correspondingly: an increase in joint load causes a linear increase in the maximum contact pressure; increasing the diameter of the endoprosthesis head - their non-linear decrease, and increasing radial clearance - their increase


Sign in / Sign up

Export Citation Format

Share Document