Enhanced Well Testing Solution to Improve Operation Safety and Reliability

2015 ◽  
Author(s):  
Jagannath Selvaraj
2020 ◽  
Author(s):  
Eugenia O'Kelly ◽  
Anmol Arora ◽  
Charlotte Pearson ◽  
James Ward ◽  
P John Clarkson

Introduction: Qualitative fit testing is a popular method of ensuring the fit of sealing face masks such as N95 and FFP3 masks. Increased demand due to the COVID-19 pandemic has led to shortages in testing equipment and has forced many institutions to abandon fit testing. Three key materials are required for qualitative fit testing: the test solution, nebulizer, and testing hood. Accessible alternatives to the testing solution have been studied. This exploratory qualitative study evaluates alternatives to the nebulizer and hoods for performing qualitative fit testing. Methods: Four devices were trialled to replace the test kit nebulizer. Two enclosures were tested for their ability to replace the test hood. Three researchers evaluated promising replacements under multiple mask fit conditions to assess functionality and accuracy. Results: The aroma diffuser and smaller enclosures allowed participants to perform qualitative fit tests quickly and with high accuracy. Discussion & Conclusion: Aroma diffusers show significant promise in their ability to allow individuals to quickly, easily, and inexpensively perform qualitative fit testing. Our findings indicate that aroma diffusers and homemade testing hoods may allow for qualitative fit testing when conventional apparatus is unavailable. Additional research is needed to evaluate the safety and reliability of these devices.


Author(s):  
Eugenia O’Kelly ◽  
Anmol Arora ◽  
Charlotte Pearson ◽  
James R. Ward ◽  
P. John Clarkson

ABSTRACT Objective: Qualitative fit testing is a popular method of ensuring the fit of sealing face masks such as N95 and FFP3 masks. Increased demand due to the coronavirus disease 2019 (COVID-19) pandemic has led to shortages in testing equipment and has forced many institutions to abandon fit testing. Three key materials are required for qualitative fit testing: the test solution, nebulizer, and testing hood. Accessible alternatives to the testing solution have been studied. This exploratory qualitative study evaluates alternatives to the nebulizer and hoods for performing qualitative fit testing. Methods: Four devices were trialed to replace the test kit nebulizer. Two enclosures were tested for their ability to replace the test hood. Three researchers evaluated promising replacements under multiple mask fit conditions to assess functionality and accuracy. Results: The aroma diffuser and smaller enclosures allowed participants to perform qualitative fit tests quickly and with high accuracy. Conclusions: Aroma diffusers show significant promise in their ability to allow individuals to quickly, easily, and inexpensively perform qualitative fit testing. Our findings indicate that aroma diffusers and homemade testing hoods may allow for qualitative fit testing when conventional apparatus is unavailable. Additional research is needed to evaluate the safety and reliability of these devices.


Author(s):  
Cagdas Senel ◽  
Altug Tuncel ◽  
Melih Balci ◽  
Ahmet Asfuroglu ◽  
Can Aykanat ◽  
...  

Geotecnia ◽  
2016 ◽  
Vol 138 ◽  
pp. 37-60
Author(s):  
Rinaldo Garcia Ramirez ◽  
◽  
Jeselay Hemetério Cordeiro dos Reis ◽  

Sign in / Sign up

Export Citation Format

Share Document