commercial kit
Recently Published Documents


TOTAL DOCUMENTS

245
(FIVE YEARS 54)

H-INDEX

20
(FIVE YEARS 2)

Pathogens ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 20
Author(s):  
Mariia Logoida ◽  
Pavol Kristian ◽  
Andrea Schreiberova ◽  
Patrícia Denisa Lenártová ◽  
Veronika Bednárová ◽  
...  

The hepatitis B virus (HBV), belonging to the Hepadnaviridae family, is responsible for a global health concern still in the 21st century. The virus is divided into 10 genotypes, which differ in geographical distribution and in their effect on disease progression and transmission, susceptibility to mutations, and response to treatment. There are many methods for diagnostics of HBV and differentiating its genotypes. Various commercial kits based on real-time polymerase chain reaction (RT PCR) and hybridization available, as well as whole genome sequencing or the sequencing of only individual parts of the genomes. We compared a commercial kit AmpliSens HBV-genotype-FRT, based on RT PCR, with an adapted method of amplification of the surface genomic region combined with Sanger sequencing. In the examined samples we identified the A, B, C, D, and E genotypes. By PCR with Sanger sequencing, the genotypes were determined in all 103 samples, while by using the commercial kit we successfully genotyped only 95 samples, including combined genotypes, which we could not detect by sequencing.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ping Han ◽  
Maybelle K. Go ◽  
Jeng Yeong Chow ◽  
Bo Xue ◽  
Yan Ping Lim ◽  
...  

AbstractAn overreliance on commercial, kit-based RNA extraction in the molecular diagnoses of infectious disease presents a challenge in the event of supply chain disruptions and can potentially hinder testing capacity in times of need. In this study, we adapted a well-established, robust TRIzol-based RNA extraction protocol into a high-throughput format through miniaturization and automation. The workflow was validated by RT-qPCR assay for SARS-CoV-2 detection to illustrate its scalability without interference to downstream diagnostic sensitivity and accuracy. This semi-automated, kit-free approach offers a versatile alternative to prevailing integrated solid-phase RNA extraction proprietary systems, with the added advantage of improved cost-effectiveness for high volume acquisition of quality RNA whether for use in clinical diagnoses or for diverse molecular applications.


2021 ◽  
Vol 71 (1) ◽  
Author(s):  
Michela Consonni ◽  
Anna Grassi ◽  
Stefania Scuri ◽  
Maria Gori ◽  
Elisabetta Tanzi ◽  
...  

Abstract Purpose Analyses of 34 water samples from 13 healthcare structures revealed how culture method and quantitative PCR (qPCR) often differ in the detection of Legionella pneumophila (Lp). With these considerations in hand, culture method, PCR and Ethidium Monoazide Bromide (EMA) qPCR have all been compared in order to detect Lp in water samples, identify a method able to speed up the procedures, detect the “viable but not cultivable” bacteria (VBNC) and exclude non-viable bacteria using a commercial kit for extraction and amplification as well as modification of the protocol. Methods Pure water samples artificially spiked with viable, non-viable and VBNC Lp ATCC 33152 were analyzed using a commercial kit for both qPCR and EMA-qPCR, while ISO 11731-2-2004 was used for culture method. Results Only 35% (12/34) of the environmental samples were positive in both culture and qPCR methods. With regard to EMA-qPCR, results showed the absence of dye toxicity on viable and VBNC strains and an incomplete effectiveness on the non-viable ones. In both viable and VBNC strains, a decrease of bacterial DNA amplification was recorded as a function of sample dilution but not of EMA concentration. Conclusions Discrepancies between culture method and EMA-qPCR were observed and may be due to different causes such as membrane-dye interactions, presence of interfering compounds and the sensitivity of the kit used. Study significance and impact In the presence of one or more suspected cases of nosocomial legionellosis, the application of a rapid molecular method able to identify only the viable and VBNC Lp would be useful in order to quickly identify the source of infection and to intervene with sanitation treatments. However, seeing that in our experience EMA pretreatment on the filter membrane did not come up with the expected results, it would be necessary to proceed with other experiments and/or different dyes. Graphical Abstract


2021 ◽  
Vol 7 (11) ◽  
pp. 949
Author(s):  
Jihane Kabtani ◽  
Khadim Diongue ◽  
Jean-Noël Dione ◽  
Anne Delmas ◽  
Coralie L’Ollivier ◽  
...  

Background. PCR assays have been developed for the diagnosis of dermatophytes, yet data in African populations are scarce. Objective. This study aimed to compare two PCR assays for the diagnosis of dermatophytosis in outpatients at the Aristide Le Dantec University Hospital in Dakar, Senegal. Patients and methods. A total of 105 samples, including 24 skin, 19 nail and 62 hair samples collected from 99 patients were included in this study. Each sample was subjected to conventional diagnosis (CD), including direct microscopy and culture, and two real-time PCR assays: one in-house (IH)-PCR, used at the University Hospital of Marseille and the Eurobio Scientific commercial kit (CK): designed for the specific detection of six dermatophytes not including Microsporum audouinii. Results. Of the 105 specimens, 24.8%, 36.2% and 20% were positive by CD, IH-PCR and CK-PCR, respectively. The IH-PCR and CK-PCR exhibited 88.9% and 65.4% sensitivity, respectively. With a 36.6 diagnostic odd ratio and 1.41 needed to diagnose, the IH-PCR displayed better diagnostic indices than the CK-PCR. It is notable that, when considering the species that it claims to detect, when it came to skin and nail samples, CK-PCR sensitivity increased to 77%. Conclusions. The pan-dermatophyte IH-PCR performed better in the diagnosis of dermatophytosis in this African population than the CK-PCR, which is not designed to detect M. audouinii. Nevertheless, both assays exhibited similarly good diagnostic indices for tinea corporis and tinea unguium, both of which are localisations where M. audouinii is more rarely involved than in tinea capitis.


2021 ◽  
Vol 2 ◽  
pp. 53-59
Author(s):  
Teodor-Stefan Ionescu ◽  
Marius Dan ◽  
Dragos Cobzariu ◽  
Stelian Baraitareanu ◽  
Doina Danes

INTRODUCTION: Seventy-six samples were collected from sixteen canine blood donors at every blood donation performed in accord with the canine donor selection guidelines. Statistical analysis of ELISA OD values revealed no significant variation of anti-rabies antibodies values during repeat donations. Our results support the statement that blood donation does not affect the immune status of donors. OBJECTIVES: The study aimed to assess the immune status against rabies among the canine blood donors in a Romanian canine blood bank METHODS: Serum samples (n=76) were collected from pet owned dogs (n=16) recorded in the blood bank register of a Romanian blood bank were performed with the immunological status of the investigated canine blood donors was evaluated using the indirect ELISA commercial kit PLATELIA RABIES II (BIO-RAD, France) as per the manufacturer's instructions RESULTS: The overall picture of ELISA OD results revealed non-significant variation between and within D1-D6 groups of values (p>0.05, F<Fcrit). CONCLUSION: The next studies topic would be to compare the results provided by the ELISA technology with FAVN.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tamir Biezuner ◽  
Ofir Raz ◽  
Shiran Amir ◽  
Lilach Milo ◽  
Rivka Adar ◽  
...  

AbstractAdvances in whole genome amplification (WGA) techniques enable understanding of the genomic sequence at a single cell level. Demand for single cell dedicated WGA kits (scWGA) has led to the development of several commercial kit. To this point, no robust comparison of all available kits was performed. Here, we benchmark an economical assay, comparing all commercially available scWGA kits. Our comparison is based on targeted sequencing of thousands of genomic loci, including highly mutable regions, from a large cohort of human single cells. Using this approach we have demonstrated the superiority of Ampli1 in genome coverage and of RepliG in reduced error rate. In summary, we show that no single kit is optimal across all categories, highlighting the need for a dedicated kit selection in accordance with experimental requirements.


Bioanalysis ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 1225-1232
Author(s):  
Nancy Yu ◽  
Mehraban Khosraviani ◽  
Yanqiu Liu

Aim: PEGylated anti-Factor D Fab (PEG-aFD) was developed as a potential therapeutic for geographic atrophy, targeting factor D, the rate-limiting enzyme in the alternative complement pathway. An assay was needed to measure total factor D as a pharmacodynamic biomarker in human aqueous humor in the presence of high PEG-aFD concentrations. Results: Commercial kit met sensitivity requirement, but not drug tolerance requirement. In-house ELISA met both drug tolerance and sensitivity requirements. Addition of 100 ng/ml PEG-aFD to the sample diluent enabled accurate measurement of human factor D in the presence of 2.5 mg/ml of PEG-aFD in the in-house ELISA. Conclusion: Accurate measurement of total factor D in human aqueous humor containing high concentrations of PEG-aFD was achieved by adding PEG-aFD to sample diluent.


2021 ◽  
pp. 1977-1987
Author(s):  
Chularat Hlaoperm ◽  
Kiattawee Choowongkomon ◽  
Chantima Pruksakorn ◽  
Jatuporn Rattanasrisomporn

Background and Aim: Helicobacter pylori is an important pathogen in humans and animals involved in chronic gastritis, leading to the development of gastric cancer. Urease produced by H. pylori is an enzyme that promotes bacterial colonization and can be used clinically as a biomarker of H. pylori infection as part of a rapid urease test (RUT). A test with high specificity (95-100%) would be more convenient and faster than histopathology, bacterial culture, and polymerase chain reaction (PCR). The aim of this study was to develop a simple, cheap, and fast kit for detecting H. pylori infection in the gastric mucosa of canines, which can be used in clinical practice for diagnosing infection with this bacterium. Materials and Methods: The RUT assays developed were prepared using 1% agar, 1% sodium phosphate monobasic, and 1% urea followed by the addition of 3% methyl red indicator. The cutoff value of sensitivity of the RUT assay was established using the urease of H. pylori ATCC 43504 and color change was monitored for 24 h. Comparisons of the sensitivity to H. pylori ATCC 43504 were made between the developed RUT assays and the Hp Fast™ commercial kit. Then, the limit of detection for H. pylori ATCC 43504 number was analyzed by the SYBR Green real-time PCR assay to measure the copy number of the ureC gene. Gastric biopsy samples from the antrum, body, and fundus of the stomach were collected from eight canines presenting with vomiting and gastroenteritis. Analyses were performed on fresh samples using the developed RUT assays and the Hp Fast™ commercial kit, which were read within 24 h; then, the results were confirmed with SYBR Green real-time PCR. The specificity of the RUT assays was tested with a number of different bacteria, including Staphylococcus pseudintermedius, Proteus spp., Pseudomonas aeruginosa, Klebsiella pneumoniae, Enterococcus spp., Escherichia coli, and Salmonella spp.; H. pylori ATCC 43504 was used as a positive control. Results: The results showed that the developed assays were sensitive to the urease enzyme at 0.1 mg/mL. The lowest detection limit of this assay for H. pylori ATCC 43504 was found to be 102 copies at 30 min. The sensitivity of detection of H. pylori in gastric biopsies of canines occurred in a minimum of 30 min. The RUT showed similar results to the Hp Fast™ commercial kit. In the developed RUT, the color change of the test from red to yellow could be clearly distinguished between the color of the positive test and the negative one; however, in the commercial Hp Fast™, it was difficult to observe the gel color change in the negative pH range of 5.8 and the positive pH of 6.5. The developed RUT was specific for H. pylori and did not detect any of the other tested bacteria. The test kit can also be stored for 6 months at 4°C. Conclusion: The sensitivity of the developed assays allowed the detection of urease enzyme at a minimum concentration of 0.1 mg/mL. Our RUT could also detect H. pylori from one in eight canine specimens at a minimum of 102 copies within 30 min. This RUT is specific to H. pylori as it did not detect any of the other tested bacteria.


2021 ◽  
Author(s):  
Michela Consonni ◽  
Anna Grassi ◽  
Stefania Scuri ◽  
Maria Gori ◽  
Elisabetta Tanzi ◽  
...  

Abstract Purpose: Culture method, Real-Time PCR (qPCR) and Ethidium Monoazide Bromide (EMA) qPCR have been compared in order to detect Legionella pneumophila (Lp) in water samples, to identify a method able to speed up the procedures, detect the “viable but not cultivable” bacteria (VBNC) and exclude dead bacteria using a commercial kit for extraction and amplification and modifying the protocol.Methods: Using these three methods, 34 environmental water samples and a series of samples artificially spiked with alive, dead and VBNC Lp ATCC 33152 were analysed. ISO 11731-2-2004 culture method was applied, whereas a commercial kit was selected for both qPCR and EMA qPCR pretreatment.Results: only 35% (12/34) of the environmental samples were positive in both culture and qPCR methods. With regard to EMA qPCR, results showed the absence of dye toxicity on viable and VBNC strains and an incomplete effectiveness on the dead ones. In both viable and VBNC strains a decrease of bacterial DNA amplification was recorded as a function of sample dilution but not of EMA concentration.Conclusions: Discrepancies between culture method and EMA-qPCR were observed and could be due to different causes as membrane-dye interactions, presence of interfering compounds and the relatively low sensitivity of the kit used.Significance and Impact of the Study: In presence of one or more suspected cases of nosocomial legionellosis, the application of a rapid molecular method able to identify only the viable and VBNC Lp would be useful in order to quickly identify the source of infection and to intervene with sanitation treatments. However, because in our experience EMA pretreatment on filter membrane has not given the expected results, it would be necessary to proceed with other experiments and different dyes.


Sign in / Sign up

Export Citation Format

Share Document