scholarly journals Effect of Strength Anisotropy on Bearing Capacity of Shallow Footing in a Dense Sand

1979 ◽  
Vol 19 (3) ◽  
pp. 15-28 ◽  
Author(s):  
Masanobu Oda ◽  
Isao Koishikawa
2019 ◽  
Vol 18 (3) ◽  
pp. 513-529
Author(s):  
Monica Malhotra ◽  
Vaishali Sahu ◽  
Amit Srivastava ◽  
Anil Kumar Misra

Purpose The purpose of this study is to investigate the effect of presence of buried flexible pipe on the bearing capacity of shallow footing. First, a model study is performed where shallow footing model is tested for its load settlement behavior, with and without the existence of buried PVC pipe lying vertically below the base of the footing. Design/methodology/approach The experimental set-up consisted of a steel box filled with sand at two different relative density values [RD = 50 per cent (medium dense) and RD = 80 per cent (dense sand)] and vertical load was applied on the model footing through hydraulic jack and reaction frame arrangement connected with a proving ring. Test results are verified numerically using commercially available finite element code PLAXIS 2D. With due verification, a parametric study has been conducted, numerically, by varying the range of input parameters, such as unit weight, angle of internal friction, diameter of buried conduit and the Elastic modulus of the soil to assess the pre cent reduction in the capacity of the foundation soil because of the presence of underlying buried flexible pipe. Findings Results show that for each footing, there exists a critical depth below which the presence of the buried conduit has negligible influence on the footing performance. When the conduit is located above the critical depth, the bearing capacity of the footing varies with various factors, such as geotechnical parameters of soil and location and diameter of the buried conduit. Originality/value It is an original paper performed to assess the presence of buried flexible pipe on the bearing capacity of the shallow footing.


2017 ◽  
Vol 17 (10) ◽  
pp. 06017018 ◽  
Author(s):  
Vishwas N. Khatri ◽  
Jyant Kumar ◽  
Shamim Akhtar

2015 ◽  
Vol 77 (11) ◽  
Author(s):  
Helmy Darjanto ◽  
Masyhur Irsyam ◽  
Sri Prabandiyani Retno

The Spider Net System Footing (SNSF) is a raft foundation system that commonly used in Indonesia. It contains a plate, downward ribs system for reinforcement, and the compacted filled soil. The ribs are in longitudinal and transversal, called as settlement rib and in diagonal direction, named as construction rib. This paper explores the load transfer mechanism along the plate, the ribs, filled soil and the base soil under the footing system. The mechanism is investigated by conducting full scale static load test on SNSF. Strain gauges were installed to monitor the strain increment of each footing elements during loading. 3D numerical analysis was also conducted to verify the experimental results. To analyze the results, Load-Ultimate Ratio Factor (L-URF) was proposed. L-URF was a ratio between ultimate soil bearing capacity of the SNSF and the applied loading at specific element. Higher the L-URF value means higher loading applied at its associate element. Both experimental and numerical results show that at the first stage the loading was fully carried out by the tip of the ribs and transferred to the soil stratum under the footing system. Increasing the loading, the ribs, plate, and filled soil altogether sustain the loading and then transferred to the soil stratum below the footing system. The results also affirm that SNSF generate higher bearing capacity compare with simple shallow footing.  


Author(s):  
Pragyan Paramita Das ◽  
Vishwas N. Khatri ◽  
Rakesh Kumar Dutta

Sign in / Sign up

Export Citation Format

Share Document