scholarly journals Seismic Response Analysis of Unit 1 of Fukushima-Daiichi Nuclear Power Plant During the 2011 Off the Pacific Coast of Tohoku Earthquake Using Three-Dimensional Finite Element Method (2nd Report: Results of Eigenanalysis and Seismic Response Analysis)

2019 ◽  
Vol 18 (3) ◽  
pp. 160-190 ◽  
Author(s):  
Shinobu YOSHIMURA ◽  
Tomoshi MIYAMURA ◽  
Tomonori YAMADA ◽  
Hiroshi AKIBA ◽  
Hideaki KIYOURA
2018 ◽  
Vol 4 (2) ◽  
Author(s):  
Masato Ono ◽  
Kazuhiko Iigaki ◽  
Hiroaki Sawahata ◽  
Yosuke Shimazaki ◽  
Atsushi Shimizu ◽  
...  

On Mar. 11, 2011, the 2011 off the Pacific coast of Tohoku Earthquake of magnitude 9.0 occurred. When the great earthquake occurred, the high temperature engineering test reactor (HTTR) had been stopped under the periodic inspection and maintenance of equipment and instruments. A comprehensive integrity evaluation was carried out for the HTTR facility because the maximum seismic acceleration observed at the HTTR exceeded the maximum value of design basis earthquake. The concept of comprehensive integrity evaluation is divided into two parts. One is the “visual inspection of equipment and instruments.” The other is the “seismic response analysis” for the building structure, equipment and instruments using the observed earthquake. All equipment and instruments related to operation were inspected in the basic inspection. The integrity of the facilities was confirmed by comparing the inspection results or the numerical results with their evaluation criteria. As the results of inspection of equipment and instruments associated with the seismic response analysis, it was judged that there was no problem for operation of the reactor, because there was no damage and performance deterioration. The integrity of HTTR was also supported by the several operations without reactor power in cold conditions of HTTR in 2011, 2013, and 2015. Additionally, the integrity of control rod guide blocks was also confirmed visually when three control rod guide blocks and six replaceable reflector blocks were taken out from reactor core in order to change neutron startup sources in 2015.


2008 ◽  
Vol 400-402 ◽  
pp. 737-742 ◽  
Author(s):  
Guo Jing He ◽  
Zhong Quan Zou ◽  
Yi Qing Ni ◽  
Jin Ming Ko

Based on the dynamic characteristics analysis results of a precise three-dimensional finite element model, the earthquake responses of the bridge are analyzed in this paper. The influences of cable local modes and stabilizing cables on the seismic response are investigated by using different mode combinations and different models. It is found that the influence of cable local modes is negligible on the side towers while significant and not negligible on the main tower; the influence of the stabilizing cables is significant and not negligible on side towers, while minor and negligible on the main tower. As for the deck displacements, the influence of cable local modes is minor and negligible, while that of longitudinal stabilizing cables is significant and not negligible.


Sign in / Sign up