Voltage Unbalance Mitigation and Voltage Profile Enhancement in Secondary Distribution System Using Dynamic Voltage Restorer

Author(s):  
Patrick Taiwo Ogunboyo ◽  
Remy Tiako ◽  
Innocent E. Davidson

This study addresses the effective mitigation of power quality disturbance such as unbalanced voltage, voltage fluctuation, voltage variation of secondary distribution network using dynamic voltage restorer (DVR). To make distribution system operate at its best performance and minimum loss, DVR is employed. The proposed system is designed using MATLAB/Simulink in Sim Power System tool box. Considering, nevertheless, that standard acceptable performance implies correct voltage profile, minimum loss, no phase shift for voltage and current, absence of overloading of transformers and electrical wires, and acceptable frequency deviation. The new setup of DVR has been put forward using dq0 controller and proportional integral (PI) controller method to improve voltage profile, correct unbalance voltage and enhance power quality problems in secondary distribution network. The simulation results attest to the ability of the proposed DVR configuration in mitigating the power quality problems in secondary distribution network.

Author(s):  
Jamal Abdul-Kareem Mohammed ◽  
Arkan Ahmed Hussein ◽  
Sahar R. Al-Sakini

<p>Power distribution network in Iraq still suffers from significant problems regarding electricity distribution level. The most important problem is the disturbances that are occurring on lines voltages, which in turn, will negatively affect sensitive loads they feed on. Protection of these loads could be achieved efficiently and economically using the dynamic voltage restorer DVR when installed between the voltage source and load to inject required compensation voltage to the network during the disturbances period. The DVR mitigates these disturbances via restoring the load voltage to a pre-fault value within a few milliseconds. To control the DVR work, dq0 transformation concept and PID method with sinusoidal pulse-width modulation SPWM based converter had been used to correct the disturbances and thus enhance the power quality of the distribution network. The DVR performance was tested by MATLAB/Simulink with all kinds of expected voltage disturbances and results investigated the effectiveness of the proposed method.</p>


Author(s):  
A. Sathik Basha ◽  
M. Ramasamy

Increased utilization of nonlinear loads in the power distribution system with profound integration of renewable energy requires improved power quality control. This paper proposes a Reformed Second Order Generalized Integrated (R-SOGI) control scheme for enhancing the output of the Dynamic Voltage Restorer (DVR) for the objective of achieving the desired sinusoidal voltage wave shape at the common point of services and harmonic reduction. The DVR incorporates a Solar Photovoltaic (SPV) system using the Z-source Inverter (ZSI), providing the necessary active power to mitigate the voltage sag/swell and power demand. ZSI offers step-down as well as step-up abilities, it makes the converters to operate in the conditions of shoot-through. Therefore, the application of ZSI-based DVR topology seems very promising. The compensating reference voltage is generated by the R-SOGI algorithm, which offers superior output under conditions for grid voltage irregularities, including voltage sag/swell and unbalanced and distorted utility grid voltages. In comparison to DVR based on the VSI voltage inverter (VSI), the response from ZSI-DVR to a reduction of voltage distortions and harmonics is investigated. An experimental SPV ZSI-DVR prototype is developed in the laboratory to check the effectiveness of the controller and is tested under balanced and unbalanced supply and dynamic load conditions.


Author(s):  
Patrick Taiwo Ogunboyo ◽  
Remy Tiako ◽  
Innocent E. Davidson

Dynamic Voltage Restorer (DVR) is a series connected power electronics based custom power device that is used to improve voltage disturbances in low voltage electrical power distribution network. Power quality requirement is one of the most important concerns for power system. The parts of the DVR is made up of voltage source inverter, injection/booster transformer, a harmonic filter, an energy storage device and a bypass switch. The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control. This paper presents a review of the researches on the dynamic voltage restorer application for power quality improvement in low voltage electrical power distribution networks. It describes power quality issues, principle of operation of DVR, basic components of DVR, DVRs control topologies in distribution network, DVR control strategies and compensation techniques.


2016 ◽  
Vol 818 ◽  
pp. 52-57 ◽  
Author(s):  
Faridullah Kakar ◽  
Abdullah Asuhaimi bin Mohd Zin ◽  
Mohd Hafiz bin Habibuddin

Voltage sag and harmonics are the most frequent power quality problems faced by industrial and commercial customers today. Situation has been aggravated by modern sensitive industrial equipments which introduce system harmonics due to their inherent V-I characteristics. In this paper, proportional integral (PI) control technique based dynamic voltage restorer (DVR) is implemented in power distribution system to suppress voltage sag and harmonics under linear, non-linear and induction motor load conditions. Real-time power distribution system and DVR test models are built in Matlab/Simulink software. Simulation results exhibit excellent PI control approach with effective performance yielding excellent voltage regulation.


2016 ◽  
Vol 36 (1) ◽  
pp. 178-185
Author(s):  
R Uhumnwangho ◽  
E Omorogiuwa ◽  
G Offor

 A study of hourly voltage log taken over a period of six months from Rumuola Distribution network Port Harcourt, Rivers State indicates that power quality problems prevalent in the Network are undervoltage/voltage sags and overvoltage/voltage swells. This paper aims at addressing these power quality problems in the distribution network using artificial neural network (ANN) controller based dynamic voltage restorer (DVR). The artificial neural networks controller engaged to controlling the dynamic voltage restorer were trained with input and output data of proportional integral (PI) controller and of unit amplitude generator obtained during simulation. All simulations and modeling were carried out in MathLab/Simulink. Proposed dynamic voltage restorer was tested with replicated model of Rumuola substation by simulating with sample of average voltage for Omerelu, Waterlines, Rumuola, Shell Industrial and Barracks feeders. Simulation results showed that DVR is effective in compensating for under-voltage and over-voltage in Rumuola Distribution network Port Harcourt, Rivers State. http://dx.doi.org/10.4314/njt.v36i1.23


Sign in / Sign up

Export Citation Format

Share Document