scholarly journals Hepatic larva migrans presenting with upper gastrointestinal haemorrhage: A case report

2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Ranjan K. Patel ◽  
Shruti Mittal

Visceral larva migrans (VLM) occurs because of a host inflammatory response to the migrating larvae of a nematode. Patients usually present with fever, hepatomegaly and abdominal pain; vascular arterial complications are uncommon. A 19-year female presented with fever, jaundice, abdominal discomfort and melena. Computed tomography (CT) revealed multiple discrete, clustered, complex hepatic cystic lesions consistent with VLM, along with an arterial pseudoaneurysm from the right hepatic artery which was managed with endovascular coil embolisation.

2021 ◽  
pp. 153857442110225
Author(s):  
Giuseppe S. Gallo ◽  
Roberto Miraglia ◽  
Luigi Maruzzelli ◽  
Francesca Crinò ◽  
Christine Cannataci ◽  
...  

We report a case of successful percutaneous transhepatic, embolization of an iatrogenic extra-hepatic pseudoaneurysm (PsA) of the right hepatic artery (RHA) under combined fluoroscopic and ultrasonographic guidance. A 73-year-old man underwent percutaneous transhepatic biliary drainage placement in another hospital, complicated by haemobilia and development of a RHA PsA. Endovascular embolization was attempted, resulting in coil embolization of the proper hepatic artery, and persistence of the PsA. At this point, the patient was referred to our hospital. Computed tomography and direct angiography confirmed the iatrogenic extra-hepatic PsA of the RHA, refilled by small collaterals from the accessory left hepatic artery (LHA) and coil occlusion of the proper hepatic artery. Attempted selective catheterization of these vessels was unsuccessful due to the tortuosity and very small caliber of the intra-hepatic collaterals, the latter precluding endovascular treatment of the PsA. Percutaneous trans-hepatic combined fluoroscopic and ultrasound-guided embolization of the PsA was performed with Lipiodol® and cyanoacrylate-based glue (Glubran®2). Real time fluoroscopic images and computed tomography confirmed complete occlusion of the pseudoaneurysm. Surgical repair, although feasible, was considered at high risk. In our patient, we decided to perform a percutaneous trans-hepatic combined fluoroscopic and ultrasound-guided embolization of the PsA using a mix of Lipiodol® and Glubran®2 because of the fast polymerization time of the glue allowing the complete occlusion of the PsA in few seconds, thus eliminating the risk of coil migration, reducing the risk of PsA rupture and avoid a difficult surgical repair.


2008 ◽  
Vol 49 (9) ◽  
pp. 987-990 ◽  
Author(s):  
Y. Katada ◽  
M. Kishino ◽  
K. Ishihara ◽  
T. Takeguchi ◽  
H. Shibuya

The arterial supply of the gallbladder usually arises from the right hepatic artery. Other origins include the left, proper, and common hepatic arteries. We report cases of the cystic artery arising from the superior mesenteric artery and arising from the dorsal pancreatic artery originating in turn from the superior mesenteric artery, as demonstrated by angiography and computed tomography.


1987 ◽  
Author(s):  
S D Blair ◽  
S B Javanvrin ◽  
C N McCollum ◽  
R M Greenhalgh

It has been suggested that mortality due to upper gastrointestinal haemorrhage may be reduced by restricting blood transfusion [1], We have assessed whether this is due to an anticoagulant effect in a prospective randomised trial.One hundred patients with severe, acute gastrointestinal haemorrhage were randomised to receive either at least 2 units of blood during the first 24 hours of admission, or no blood unless their haemaglobin was lessthan 8g/dl or they were shocked. Minor bleeds and varices were excluded As hypercoagulation cannot be measured using conventional coagulation tests, fresh whole blood coagulation was measured by the Biobridge Impedance Clotting Time (ICT). Coagulation was assessed at 24 hour intervals and compared to age matched controls with the results expressed as mean ± sem.The ICT on admission for the transfusion group (n=50) was 3.2±0.2 mins compared to 10±0.2 mins in controls. This hyper-coagulable state was partially reversed to 6.4±0.3 mins at 24 hours (p<0.001). The 50 allocated to receive no blood had a similar ICT on admission of 4.4±0.4 mins but the hypercoagulable state was maintained with ICT at 24 hours of 4.320.4 mins. Only 2 patients not transfused rebled compared to 15 in the early transfusion group (p<0.001). Five patients died, and they were all in the early transfusion group.These findings show there is a hypercoagulable response to haemorrhage which is partially reversed by blood transfusion leading to rebleeding


2020 ◽  
Vol 8 ◽  
pp. 232470962098243
Author(s):  
Khalid Sawalha ◽  
Anthony Kunnumpurath ◽  
Ronald McCann

An 80-year-old male patient presented with sepsis secondary to infected central line which was placed for native aortic valve endocarditis. He also had melena and abdominal pain prior to his presentation. Abdominal computed tomography (CT) was done, which showed cholelithiasis. Esophagogastroduodenoscopy was also done with no source of bleeding identified. Later, he developed hemodynamic instability requiring aggressive fluid resuscitation and multiple packed blood cell transfusions. In view of his hemodynamic instability, a repeat abdominal CT scan showed air droplets within the gallbladder pneumobilia, ascites, diverticulosis, and a bleeding infrahepatic hematoma measuring 6 × 10 cm, which was not on his prior scan 2 days prior. A mesenteric arteriogram was performed that identified an aneurysm of the right hepatic artery with no active bleeding; therefore, it was coiled. Due to his continued clinical decompensation, he underwent an urgent open cholecystectomy, in which serosanguineous fluid, cholecystocolic fistula, and old clot related to his previous bleed were encountered. However, control of bleeding was difficult, and the patient expired. We report this case of right hepatic artery aneurysm that we believe its etiology was related to eroding cholecystitis.


Sign in / Sign up

Export Citation Format

Share Document