Evaluation of acoustic shock induced early hearing loss with audiometer and distortion product otoacoustic emissions

2010 ◽  
Vol 64 (3) ◽  
pp. 132 ◽  
Author(s):  
RS Vinodh ◽  
N Veeranna
2006 ◽  
Vol 2 (1) ◽  
pp. 2-9
Author(s):  
Tiffany A. Johnson ◽  
Stephen T. Neely ◽  
Michael P. Gorga

2021 ◽  
Vol 29 (2) ◽  
pp. 189-195
Author(s):  
Vybhavi MK ◽  
Srinivas V

Introduction  The present study was devised to estimate the prevalence of neonatal hearing loss and document the importance of using DPOAE as a screening tool for identifying hearing loss in newborns. Materials and Methods This hospital based descriptive study was conducted from August 2018 to August 2019. A total of 928 newborn babies were included in the study. These newborn babies were subjected to hearing screening by distortion product otoacoustic emissions (DPOAE) at 24-72 hrs after birth. For pass cases, no further testing was done. For refer cases, repeat testing with DPOAE was done within 15-30 days. Newborns with refer result on repeat DPOAE testing were subjected to Brainstem evoked response audiometry (BERA) within 3 months to confirm hearing loss. Results Nine hundred and twenty eight newborn babies were screened by DPOAE. 851 newborns passed the first DPOAE hearing screening and 77 newborns gave refer result. 21 newborns were lost to follow-up. 56 newborns underwent repeat DPOAE testing and 5 newborns were referred for BERA. Amongst the 5 newborns who underwent BERA testing, one newborn was diagnosed with bilateral profound hearing loss. Hence, the prevalence of hearing loss of 1.08 per thousand newborn babies was estimated in this study. Conclusion Hearing screening of newborns using DPOAE followed by BERA in refer cases to confirm hearing loss is useful for early detection followed by timely intervention and rehabilitation.


2009 ◽  
Vol 251 (1-2) ◽  
pp. 17-28 ◽  
Author(s):  
Diana Turcanu ◽  
Ernst Dalhoff ◽  
Marcus Müller ◽  
Hans-Peter Zenner ◽  
Anthony W. Gummer

2017 ◽  
Vol 131 (11) ◽  
pp. 1017-1025 ◽  
Author(s):  
H Keppler ◽  
S Degeest ◽  
I Dhooge

AbstractObjectives:Chronic tinnitus is associated with reduced auditory input, which results in changes in the central auditory system. This study aimed to examine the relationship between tinnitus pitch and parameters of audiometry and distortion product otoacoustic emissions. For audiometry, the parameters represented the edge frequency of hearing loss, the frequency of maximum hearing loss and the frequency range of hearing loss. For distortion product otoacoustic emissions, the parameters were the frequency of lowest distortion product otoacoustic emission amplitudes and the frequency range of reduced distortion product otoacoustic emissions.Method:Sixty-seven patients (45 males, 22 females) with subjective chronic tinnitus, aged 18 to 73 years, were included.Results:No correlation was found between tinnitus pitch and parameters of audiometry and distortion product otoacoustic emissions. However, tinnitus pitch fell mostly within the frequency range of hearing loss.Conclusion:The current study seems to confirm the relationship between tinnitus pitch and the frequency range of hearing loss, thus supporting the homeostatic plasticity model.


2002 ◽  
Vol 122 (5) ◽  
pp. 20-25 ◽  
Author(s):  
S. Hatzopoulos ◽  
C. Amoroso ◽  
C. Aimoni ◽  
A. Lo Monaco ◽  
M. Govoni ◽  
...  