scholarly journals A prospective study to assess the surgical outcome in three- and four-part proximal humerus fracture with PHILOS plate

2012 ◽  
Vol 39 (1) ◽  
pp. 12
Author(s):  
MahanteshY Patil ◽  
AB Patil ◽  
Sharat Balemane
Author(s):  
Mukka Naveen ◽  
D. Narsimlu

Introduction: Proximal humerus fracture is considered as one of the commonest fractures in clinical practice. Most of these fractures occur as a result of osteoporosis. Proximal humerus fractures are often nondisplaced or minimally displaced fractures with two parts, which can be managed conservatively. Surgical interventions include closed reduction and percutaneous pinning (CRPP). It also involves trans-osseous suture fixation, Open Reduction Internal Fixation (ORIF) with either conventional or Proximal Humerus Interlocking Osteosynthesis System (PHILOS) or hemiarthroplasty. Good clinical outcomes have been achieved by the PHILOS as they stabilize the proximal humeral fractures with steady fixation in osteoporotic bone and assisted aged patients in early functional exercises which resulted in early recovery.  Aim: To analyse the functional results and complications associated with management of proximal humerus fractures treated with PHILOS. Materials and Methods: This is a prospective study conducted at Department of Orthopaedics, Prathima Institute Of Medical Sciences, Nagunur, Karimnagar, from July 2017 to January 2019.  58 patients were taken into study with two-part, three-part, four-part fracture of the proximal humerus in adults >18 years of age. In all patients PHILOS plating was done and surgical events and surgical difficulties faced, post-surgery local or systemic complications, time needed for fracture union and time taken to return to pre-fracture activity were documented. They were followed up till there were signs of union on radiographs or for at least a period of 1 year. Results: The results were assessed with Constant Murley Score at 6 months post-surgery and Visual Analogue Scale at 6 weekly intervals. The mean Constant score for two-part fractures was 88.1, for Three-part 82.5, for Four-part 72.7. The patients with two-part and three-part fractures had a significantly better VAS than patients with four-part fractures till 18 months of surgery. After 18 months the VAS was similar for all 3 groups. 6.9% developed shoulder stiffness, 2 patients from four-part fracture group developed Varus angulation. Conclusion: we conclude that the PHILOS is safe, effective and provides stable fixation for  proximal humerus fractures and in patients with indigent bone quality.  Keywords:  PHILOS, Proximal Humerus Fracture


Author(s):  
C. D. Deepak ◽  
Mahesh D. V. ◽  
Abdul Ravoof ◽  
Manash Jyoti Baruah

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Fractures of the proximal humerus are the second most common upper extremity fracture and the third most common fracture, after hip and distal radial fractures. The fractures can occur at any age, but the incidence rapidly increases with age.</span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">The study was conducted in patients treated for displaced proximal humerus fracture at Adichunchanagiri Institute Of Medical Sciences, BG Nagar from the month of June 2014 to August 2016. Twenty proximal humerus fracture patients were taken into the study; all were fixed with PHILOS plate. Patients’ age ranged from 18 to 75 years with a mean of 42.9</span>.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">The sample consisted of twenty patients of proximal humeral fractures. 08 were males and 12 females. The patients’ ages ranged from 18-75 years with a mean age of 42.9 years. The causes of fractures were road traffic accident in 13 patients, fall in 06 patients and electric shock in 1 patient. 11 fractures involved the right side and 09 involved the left. Patients were followed up from 03 weeks to 06 months. Functional outcome was rated as per Constant-Murley Shoulder Score, we got excellent results in 04 cases, satisfactory in 10, unsatisfactory in 05 xi and failure in 01 patient. Mean Constant-Murley score of this study at the end of the final follow-up period was 81.6. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">The PHILOS plate is a good implant to use for fractures of the proximal humerus. However, proper placement of the plate and fixation are required to produce satisfactory results. We recommend use of this implant in Neer 2-part, 3-part, 4-part fractures with or without dislocation and osteoporotic fractures.</span></p>


Author(s):  
Bhavik Y. Dalal ◽  
Dipalkumar V. Rathod ◽  
Raghav Suthar ◽  
Harshal Damor

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">This study was undertaken to evaluate the efficacy of Philos plate and to specifically study the clinical outcome of the patient treated with Philos plate for proximal humerus fracture on the radiological head shaft angle basis.</span></p><p class="abstract"><strong>Methods:</strong> 40 cases of proximal humerus fracture fixed by using Philos plate were reviewed.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">Average constant shoulder score as Neer type-3 fracture is 83.8% and for type- 4 part fracture is 86%. Average radiological union was seen at 10.2 weeks. There was no major difference in clinical and radiological union. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">Good functional outcome with Philos plate irrespective of fracture type was obtained.</span></p>


2020 ◽  
Vol 6 (4) ◽  
pp. 472-477
Author(s):  
Dr. R Neelakrishnan ◽  
Dr. S Saran Prasath ◽  
Dr. V Bharathiselvan ◽  
Dr. PS Balamurgavel ◽  
Dr. K Parasuraman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document