2015 ◽  
Vol 7 (3) ◽  
pp. 317-322
Author(s):  
Dominykas Beištaras

This paper presents liquid level control system model and analysis of dynamic characteristics. The system consists of scalar controlled induction motor drive, fuzzy logic controller, water tank and centrifugal pump. Simulink models of water tank, pump and controller are presented. The simulation of the system shows that the use of fuzzy logic controller reduces valve opening time and reservoir filling time. Nagrinėjamas skysčio lygio valdymo sistemos imitacinių modelių sudarymas, analizuojamos dinaminės charakteristikos. Valdymo sistema sudaryta iš skaliariniu būdu valdomos dažninės elektros pavaros su neraiškiosios logikos reguliatoriumi, vandens rezervuaro ir išcentrinio siurblio. Sudaryti rezervuaro, siurblio ir reguliatoriaus Simulink modeliai. Atlikus imitacijas gauta nedimensinė siurblio charakteristika, apibūdinanti siurblio veikimą, esant bet kokiam sukimosi greičiui. Nustatyta, kad sistemoje su neraiškiosios logikos reguliatoriumi vožtuvas yra atidaromas greičiau nei sistemoje su proporcinguoju integraliniu (PI) reguliatoriumi, ir todėl sumažinama rezervuaro pripildymo trukmė.


Author(s):  
Dan Guo ◽  
Hong Xia

Steam generator (SG) water level system is a highly complex nonlinear time-varying system. It is complicated at low power levels due to shrink and swell phenomena which must be considered for plant safety and availability. To improve the transient performance of the SG level subject to power adjustments, an innovative set-point function method is put forward in this paper. The set-point functions based on the inverse-control theory and the swell and shrink effect which generate a desirable reference input to the widespread cascade Proportional Integral Derivative (PID) controller of the level control system respectively. The set-point function can apply appropriate control to the feed-water flow rate duly depended on the pivotal time between the power adjustment decision and the real start time of adjustment. Finally, comparative simulation is carried out under the same condition of power adjustment. The simulation results demonstrate that the water level control system added set-point functions can restrain the disturbance and improve the transient performance effectively. The method added the Inverse Control-Based Set-Point (ICSP) function can achieve better control performances than the swell-based set-point (SBSP) function.


1997 ◽  
Vol 30 (17) ◽  
pp. 155-160
Author(s):  
Wen-peng Lang ◽  
M. Tahir Khaleeq ◽  
David Guosen He ◽  
Weiqing Zhao

Sign in / Sign up

Export Citation Format

Share Document