scholarly journals Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

2018 ◽  
Vol 14 (4) ◽  
pp. 347-355
Author(s):  
Paweł Gąsior ◽  
Marek Gierlotka ◽  
Krzysztof Szczurek-Katanski ◽  
Marcin Osuch ◽  
Magda Roleder ◽  
...  
2021 ◽  
Author(s):  
mingkun cao ◽  
Yuxia Yin ◽  
Chao Zhou ◽  
Wei Deng ◽  
Jianying Ma ◽  
...  

Abstract Background Drug-eluting stent (DES) with durable polymers have been proven to cause late or very late adverse events. Biodegradable polymer-coated DES was developed to address the risk by avoiding persistent inflammatory irritation from persistent polymers. However, it is unknown whether the benefits of biodegradable polymer DES will occur over longer time. Methods The trial was a prospective, multicenter and randomized non-inferiority clinical trial done in China. Patients with indications for stent implantation were assigned into Cordimax and Xience V group in a 2:1 allocation. The composite of cardiac death, target vessel myocardial infarction (TV-MI), or clinically indicated target lesion revascularisation (CI-TLR) was the primary endpoint target lesion failure (TLF). The pre-specified endpoint at five years was major adverse cardiac event (MACE) which was defined as a composite of all-cause death, non-fatal myocardial infarction (MI), and CI-TLR. Results 3266 patients (88.3%) completed 5-year follow-up. No difference was observed for TLF between Cordimax (7.5%) and Xience V (8.3%) group (RR: 0.90, 95% CI: 0.70 to 1.15, P = 0.39). MACE occurred in 280 patients (11.4%) in Cordimax group and 162 patients (13.1%) in Xience V group (RR: 0.85, 95% CI: 0.69 to 1.05, P = 0.13). The incidence of definite or probable stent thrombosis did not differ in both groups (Cordimax 0.7%, Xience V 0.9%; RR: 0.78, 95% CI: 0.36 to 1.66; P = 0.51). Conclusion The biodegradable polymer Cordimax stent showed a comparable result to the durable polymer Xience V stent at 5 years, showing its long-term safety and efficacy performance. Trial registration: This study is registered with ClinicalTrials.gov, number NCT03185221 (14/06/2017).


2019 ◽  
Vol 12 (4) ◽  
pp. S7
Author(s):  
Seung-Woon Rha ◽  
Ahmed Mashaly ◽  
Byoung Geol Choi ◽  
Se Yeon Choi ◽  
Jae Kyeong Byun ◽  
...  

2015 ◽  
Vol 183 ◽  
pp. 190-197 ◽  
Author(s):  
Hyun Jong Lee ◽  
Taek Kyu Park ◽  
Young Bin Song ◽  
Young Jin Choi ◽  
Cheol Woong Yu ◽  
...  

Angiology ◽  
2016 ◽  
Vol 68 (8) ◽  
pp. 698-706
Author(s):  
Jeong Cheon Choe ◽  
Kwang Soo Cha ◽  
Hye Yoon Jang ◽  
Jong Hyun Choi ◽  
Bo Won Kim ◽  
...  

We compared outcomes between biodegradable polymer biolimus-eluting stent (BP-BES) and new-generation durable polymer drug-eluting stent (DP-DES) implantations in patients with acute myocardial infarction (MI). Among 13472 patients with acute MI in a nationwide registry, 557 (64.8%) were in the BP-BES and 303 (35.2%) in the new-generation DP-DES group following coronary reperfusion. The occurrence of major adverse cardiac events (MACE; death, MI, revascularization) and stent thrombosis was compared. Major adverse cardiac events occurred in 53 (6.2%) patients and showed similar rates between the BP-BES and new-generation DP-DES groups (all: 6.6% vs 5.9%, P = .652; propensity score [PS] matched: n = 380, 6.3% vs 5.3%, P = .623). Stent thrombosis did not differ between groups (all: 0.3% vs 0.4%, P = .892; PS matched: 0.5% vs 0.5%, P = 1.000). Major adverse cardiac event-free survival was comparable between groups (all: 93.4% vs 94.1%, log-rank P = .357; PS matched: 93.7% vs 94.7%, log-rank P = .445). Biodegradable polymer biolimus-eluting stent was not associated with MACE (all: hazard ratio [HR], 1.67; 95% confidence interval [CI], 0.75-3.74; P = 0.212; PS matched: HR, 1.05; 95% CI, 0.40-2.75; P = .915). In conclusion, in patients with acute MI, BP-BES was equivalent to the new-generation DP-DES in terms of outcomes.