scholarly journals Calculation of response functions for cylindrical nested neutron spectrometer

2021 ◽  
Vol 7 (3) ◽  
pp. 52-56
Author(s):  
Vu Long Chu ◽  
Huu Quyet Nguyen ◽  
Ngoc Quynh Nguyen ◽  
Ngoc Thiem Le

In a recent work, a new neutron spectrometer, namely Cylindrical Nested Neutron Spectrometer (CNNS). It works under the same principles as a Bonner Sphere Spectrometer (BSS), except that different amounts of moderator around a thermal neutron detector are configured by adding or removing cylindrical shells. The CNNS consists of a 4mm x 4mm 6LiI(Eu) scintillator crystal and nested cylindrical polyethylenemoderators. The objective of this paper is describing the use of MCNPX code for determining a optimal ratio between height and diameter of the moderators in order to remain isotropic angular response to neutrons like BSS and determining of response functions for moderators of different diameters at 104 energy points from 0.001 eV to 19.95 MeV.

2017 ◽  
Vol 20 (2) ◽  
pp. 65 ◽  
Author(s):  
Rasito Tursinah ◽  
Bunawas Bunawas ◽  
Jungho Kim

Neutron Response Function of Bonner Sphere Spectrometer With 6LiI(Eu) Detector. The detector response function was needed to measure the neutron fluence based on the count rates from Bonner Sphere Spectrometer (BSS). The determination of response function of a BSS with 6LiI(Eu) detector has been performed using Monte Carlo MCNPX code. This calculation was performed for BSS using scintillation detector of 4 mm × 4 mm 6LiI(Eu) which is placed at the center of a set of polyethylene spheres i.e bare, 2", 3", 5", 8", 10", and 12" diameters. The BSS response functions were obtained for neutron energy of 1x10-9 MeV - 1x102  MeV in 111 energy bins and each value has an uncertainty less or equal to 2 %. The response function were compared with two response functions reported in the literature i.e IAEA document in Technical Reports Series 403 (TRS-403) and the calculation from Vega-Carrillo, et al. Also validated with measurement 252Cf neutron spectra, that shown the simulated BSS spectra were quite close to the experimental measured with a differrence of 3%.


2009 ◽  
Author(s):  
Xiao-hu Wang ◽  
Yuan-bo Chen ◽  
Huan-yi Sheng ◽  
Yu-bin Zhao ◽  
Hong-yu Zhang ◽  
...  

2005 ◽  
Vol 52 (6) ◽  
pp. 3151-3156 ◽  
Author(s):  
A. Syntfeld ◽  
M. Moszynski ◽  
R. Arlt ◽  
M. Balcerzyk ◽  
M. Kapusta ◽  
...  

2008 ◽  
Vol 72 (7) ◽  
pp. 1001-1004 ◽  
Author(s):  
V. A. Andreev ◽  
E. A. Ivanov ◽  
D. S. Ilyin ◽  
S. N. Kovalenko ◽  
A. G. Krivshich ◽  
...  

1999 ◽  
Vol 46 (6) ◽  
pp. 1916-1919 ◽  
Author(s):  
G.J. Mahler ◽  
V. Radeka ◽  
N.A. Schaknowski ◽  
G.C. Smith ◽  
B. Yu ◽  
...  

Author(s):  
Martín Pérez ◽  
Juan Jerónimo Blostein ◽  
Fabricio Alcalde Bessia ◽  
Aureliano Tartaglione ◽  
Iván Sidelnik ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document