scholarly journals Endovascular treatment of vertebrobasilar system aneurysms — long term results

Author(s):  
Paweł Szmygin ◽  
Maciej Szmygin ◽  
Tomasz Roman ◽  
Tomasz Jargiełło
Neurosurgery ◽  
2021 ◽  
Vol 89 (Supplement_2) ◽  
pp. S164-S164
Author(s):  
Marta Aguilar Pérez ◽  
Elina Henkes ◽  
Victoria Hellstern ◽  
Carmen Serna Candel ◽  
Christina Wendl ◽  
...  

Author(s):  
Ákos Bérczi ◽  
Miklós Vértes ◽  
Tin Dat Nguyen ◽  
Viktor Bérczi ◽  
Balázs Nemes ◽  
...  

2018 ◽  
Vol 52 (5) ◽  
pp. 335-343 ◽  
Author(s):  
Federico Fontana ◽  
Edoardo Macchi ◽  
Filippo Piacentino ◽  
Larissa Nocchi Cardim ◽  
Giuseppe De Marchi ◽  
...  

Purpose: To evaluate the variations in aortic diameters and long-term results in patients who underwent thoracic endovascular aortic repair (TEVAR) for acute blunt traumatic thoracic aortic injuries (BTTAIs). Materials and Methods: We retrospectively evaluated 23 patients with a mean age of 39 years (range: 17-74 years) who underwent TEVAR for BTTAI between October 2000 and November 2014. All of the patients underwent computed tomography angiography (CTA) before hospital discharge as a baseline imaging for the subsequent follow-up examinations. The technical success, overall survival, and complications were evaluated. Furthermore, the aortic diameters outside of the stent-graft (1 cm proximal and 1 cm distal to the stent-graft) and the aortic diameters within the stent-graft (2 cm distal to the proximal end and 2 cm proximal to the distal end) were assessed. The diameters at baseline on CTA were compared with those of the latest available follow-up examination. Results: Technical success was 100% with a mean follow-up of 65.4 months (range: 12-171 months). No death was registered, and 2 (8.7%) of 23 endograft-related complications (1 stent-graft distal infolding and 1 endoleak 2 and 4 months after the procedure, respectively) were observed. An increase in aortic diameter either proximal or distal to the stent-graft (mean value 0.7 and 0.5 mm, respectively) or within the stent-graft (mean value of 0.5 mm for both proximal and distal diameters) was registered (mean follow-up at 65.4 months, range: 12-171 months). Conclusion: Aortic dilatation following TEVAR for BTTAI is minimal during long-term follow-up. Endovascular treatment represents a durable and safe option in acute BTTAIs.


2014 ◽  
Vol 29 (3) ◽  
pp. 353-358 ◽  
Author(s):  
Spiridon Botsios ◽  
Johannes Frömke ◽  
Gerhard Walterbusch ◽  
Karl Schuermann ◽  
Jan Reinstadler ◽  
...  

2010 ◽  
Vol 17 (4) ◽  
pp. 504-509 ◽  
Author(s):  
Giovanni Torsello ◽  
Eva Schönefeld ◽  
Nani Osada ◽  
Martin Austermann ◽  
Corinna Pennekamp ◽  
...  

2016 ◽  
Vol 22 (6) ◽  
pp. 654-658 ◽  
Author(s):  
Christopher J Stapleton ◽  
Collin M Torok ◽  
Aman B Patel

Background Penumbra SMART coils differ from traditional microcoils used for endovascular coil embolization of intracranial aneurysms (IAs) in that they (1) become progressively softer from their distal to proximal end, rather than being of uniform stiffness, (2) have a tight conformational structure, and (3) have a more robust stretch-resistance platform. These properties aid in preventing microcatheter prolapse and coil herniation during coil deployment and in filling small pockets of the aneurysm sac. Objective/Methods To determine the safety and efficacy of this device, the records of 17 consecutive patients with IAs treated with SMART coils were retrospectively analyzed. Results Thirteen female and four male patients were identified. Eleven patients presented with subarachnoid hemorrhage, four had recurrent aneurysms, and two had incidentally discovered aneurysms. Twelve aneurysms (two of which were recurrent) were treated with stand-alone coiling, three were treated with stent-assisted coiling, and two with flow diversion with adjuvant coiling. Microcatheter prolapse occurred in one case of a recurrent aneurysm, due to mechanical limitations imposed by a stent placed during prior coiling. Raymond-Roy Occlusion Classification (RROC) I or II occlusion was achieved in 12 aneurysms, including all 10 undergoing primary stand-alone coiling. Of the five RROC III occlusions, two were expected given treatment with flow diversion, while the other three occurred in complex, recurrent aneurysms. One patient suffered a thromboembolic complication of unclear clinical significance. Conclusions The Penumbra SMART coil is a safe and effective device for the endovascular treatment of IAs. Follow-up studies are required to establish long-term results.


2019 ◽  
Vol 130 (3) ◽  
pp. 895-901 ◽  
Author(s):  
Michael A. Mooney ◽  
Elias D. Simon ◽  
Scott Brigeman ◽  
Peter Nakaji ◽  
Joseph M. Zabramski ◽  
...  

OBJECTIVEA direct comparison of endovascular versus microsurgical treatment of ruptured middle cerebral artery (MCA) aneurysms in randomized trials is lacking. As endovascular treatment strategies continue to evolve, the number of reports of endovascular treatment of these lesions is increasing. Herein, the authors report a detailed post hoc analysis of ruptured MCA aneurysms treated by microsurgical clipping from the Barrow Ruptured Aneurysm Trial (BRAT).METHODSThe cases of patients enrolled in the BRAT who underwent microsurgical clipping for a ruptured MCA aneurysm were reviewed. Characteristics of patients and their clinical outcomes and long-term angiographic results were analyzed.RESULTSFifty patients underwent microsurgical clipping of a ruptured MCA aneurysm in the BRAT, including 21 who crossed over from the endovascular treatment arm. Four patients with nonsaccular (e.g., dissecting, fusiform, or blister) aneurysms were excluded, leaving 46 patients for analysis. Most (n = 32; 70%) patients presented with a Hunt and Hess grade II or III subarachnoid hemorrhage, with a high prevalence of intraparenchymal blood (n = 23; 50%), intraventricular blood (n = 21; 46%), or both. At the last follow-up (up to 6 years after treatment), clinical outcomes were good (modified Rankin Scale score 0–2) in 70% (n = 19) of 27 Hunt and Hess grades I–III patients and in 36% (n = 4) of 11 Hunt and Hess grade IV or V patients. There were no instances of rebleeding after the surgical clipping of aneurysms in this series at the time of last clinical follow-up.CONCLUSIONSMicrosurgical clipping of ruptured MCA aneurysms has several advantages over endovascular treatment, including durability over time. The authors report detailed outcome data of patients with ruptured MCA aneurysms who underwent microsurgical clipping as part of a prospective, randomized trial. These results should be used for comparison with future endovascular and surgical series to ensure that the best results are being achieved for patients with ruptured MCA aneurysms.


Sign in / Sign up

Export Citation Format

Share Document