scholarly journals Endovascular Treatment of Anterior Circulation Aneurysms With the p64 Flow Modulation Device: Mid- and Long-Term Results in 617 Aneurysms From a Single Center

Neurosurgery ◽  
2021 ◽  
Vol 89 (Supplement_2) ◽  
pp. S164-S164
Author(s):  
Marta Aguilar Pérez ◽  
Elina Henkes ◽  
Victoria Hellstern ◽  
Carmen Serna Candel ◽  
Christina Wendl ◽  
...  
2014 ◽  
Vol 28 (3) ◽  
pp. 659-664 ◽  
Author(s):  
Domenico Angiletta ◽  
Raffaele Pulli ◽  
Davide Marinazzo ◽  
Pietro Frotino ◽  
Luisa Maiellaro ◽  
...  

2021 ◽  
Vol 12 ◽  
Author(s):  
Victoria Hellstern ◽  
Marta Aguilar-Pérez ◽  
Elina Henkes ◽  
Carmen Serna-Candel ◽  
Christina Wendl ◽  
...  

Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment of saccular, unruptured aneurysms in the posterior circulation over a long-term follow-up period in a single center.Methods: From our prospectively maintained database, we retrospectively identified patients who underwent treatment of an intracranial saccular aneurysm arising from the posterior circulation with ≥1 p64 FD implanted or attempted between October 2012 and December 2019. Aneurysms could have been treated with prior or concomitant saccular treatment (e.g., coiling, intra-aneurysmal flow diversion). Aneurysms with parent vessel implants other than p64, fusiform aneurysms, and dissections were excluded. Peri- and postprocedural complications, clinical outcome, and clinical and angiographic follow-up results were evaluated.Results: In total, 54 patients (45 female, 9 male; mean age 55.1 years) with 54 intracranial aneurysms met the inclusion criteria. In 51 cases (94.4%), one p64 was implanted; in 2 cases (3.7 %), two p64s were implanted; in one case, deployment of the p64 was not feasible. Procedural complications occurred in 3.7% and postprocedural complications in 9.3 %, respectively. Hemorrhagic complications occurred in 2/54 patients (3.7%), thereof one fatal parenchymal hemorrhage. Ischemic complications were observed in 5/54 patients (9.3%). Early, mid-term, and long-term angiographic follow-up examinations showed complete or near-complete aneurysm occlusion, defined according to the O'Kelly –Marotta (OKM) scale as OKM C + D in 56, 75.6, and 82.9 %, respectively. Asymptomatic side vessel occlusions occurred in 3.8%, each during the first follow-up.Conclusions: The implantation of a p64 FD is a safe and effective device for endovascular treatment of posterior circulation saccular aneurysms with a high success rate and low morbi-mortality.


2013 ◽  
Vol 55 (5) ◽  
pp. 416-421
Author(s):  
F. Aparici Robles ◽  
E. Mainar Tello ◽  
V. Vázquez-Añón ◽  
A. Lago Martín ◽  
V. Parkhutik ◽  
...  

2010 ◽  
Vol 58 (S 01) ◽  
Author(s):  
S Kueri ◽  
B Nitsch ◽  
C Heilmann ◽  
J Schneider ◽  
C Schlensak ◽  
...  

2021 ◽  
Author(s):  
Marta Aguilar Pérez ◽  
Elina Henkes ◽  
Victoria Hellstern ◽  
Carmen Serna Candel ◽  
Christina Wendl ◽  
...  

Abstract BACKGROUND Flow diverters have become an important tool in the treatment of intracranial aneurysms, especially when dealing with difficult-to-treat or complex aneurysms. The p64 is the only fully resheathable and mechanically detachable flow diverter available for clinical use. OBJECTIVE To evaluate the safety and effectiveness of p64 for the treatment of intracranial saccular unruptured aneurysms arising from the anterior circulation over a long-term follow-up period. METHODS We retrospectively reviewed our prospectively maintained database to identify all patients who underwent treatment for an intracranial saccular (unruptured or beyond the acute hemorrhage phase) aneurysm arising from the anterior circulation with ≥1 p64 between December 2011 and December 2019. Fusiform aneurysms and dissections were excluded. Aneurysms with prior or concomitant saccular treatment (eg, coiling and clipping) were included. Aneurysms with parent vessel implants other than p64 were excluded. Anatomic features, intraprocedural complications, clinical outcome, as well as clinical and angiographic follow-ups were all recorded. RESULTS In total, 530 patients (388 females; median age 55.9 yr) with 617 intracranial aneurysms met the inclusion criteria. The average number of devices used per aneurysm was 1.1 (range 1-3). Mean aneurysm dome size was 4.8 mm (range 1-27 mm). Treatment-related morbimortality was 2.4%. Early, mid-term, and long-term angiographic follow-up showed complete or near-complete aneurysm occlusion in 76.8%, 89.7%, and 94.5%, respectively. CONCLUSION Treatment of intracranial saccular unruptured aneurysms of the anterior circulation using p64 is a safe and effective treatment option with high rate of occlusion at long-term follow-up and low morbimortality.


Sign in / Sign up

Export Citation Format

Share Document