Tetiana Arhatenko ◽  
...  

The process of carbonization of concrete with different ratio of water to cement (W/C) was studied, and the influence of the environment on corrosion damage of reinforced concrete reinforcement was studied. The results of the study of carbonization of concrete on specially prepared model samples of concrete with a size of 250x250x250 mm with an exposure period in NACE solution for 500 days without external load are presented. Measurements of corrosion damage of reinforcing rods, which were placed inside concrete cubes, were performed. The method of estimating the amount of carbonization of concrete and corrosion of reinforcement is described in detail in known scientific papers. The obtained data testify to the active carbonization of concrete during the whole exposure period of the samples in NACE solution, however, concrete prepared at the ratio W/C = 0.5 and 0.6 is particularly significant in terms of carbonization intensity. Concrete with a ratio of W/C = 0.7 is less susceptible to damage. Moreover, a similar trend is observed for corrosion of fittings. This is due to the fact that the increase of the aqueous medium in the concrete mass facilitates diffusion processes of delivery to the reactive zone of chemically aggressive ingredients such as carbon dioxide, chloride ions, hydrogen, sulfur, sulfate ions, various types of bacteria and the like. The kinetics of concrete carbonization and corrosion of reinforcing bars in chemically aggressive NACE medium depending on the exposure period of the samples in the model solution was experimentally studied. It is established that with the increase of the water-cement ratio W/C from 0.5 to 0.7, the depth of carbonization and the layer thickness of corrosion products increase sharply. The flooding of the surface layers of the reinforcement and their strong embrittlement in the process of long-term operation of the reinforcement in the structure of reinforced concrete, which causes a decrease in crack resistance in general of reinforced concrete structures. The degradation of reinforcing steel during long-term operation in aggressive environments, which leads to premature corrosion damage to the reinforcement with subsequent destruction of the structure, was investigated experimentally with the involvement of high-precision metallographic equipment.


2014 ◽  
Vol 644-650 ◽  
pp. 5273-5276
Author(s):  
Xiao Rui Guan ◽  
Da Lei Zhang ◽  
Jian Jun Wang ◽  
You Hai Jin

The corrosion behavior of X80 pipeline steel with quinoline inhibitor in NACE solution (CO2 environment) at different temperature/different pH/different inhibitor volume fraction was researched using electrochemical test methods. The results show that as the temperature increases from 30°C to 50°C, CO2 corrosion of X80 pipeline steel becomes much severer and the inhibition efficiency decreases first and then increases. As the pH increases from 4.15 to 5.76, the inhibition efficiency increases. When the volume fraction of inhibitor ranges from 2% to 4%, the inhibition efficiency increases, and particularly this is more obvious from 2% to 3%.


2010 ◽  
Vol 45 (2) ◽  
pp. 181-184 ◽  
Author(s):  
X. M. Dong ◽  
Q. C. Tian ◽  
Q. A. Zhang