vessel sharpness
Recently Published Documents


TOTAL DOCUMENTS

3
(FIVE YEARS 0)

H-INDEX

1
(FIVE YEARS 0)

2020 ◽  
Vol 33 (5) ◽  
pp. 627-640
Author(s):  
Karina López ◽  
Radhouene Neji ◽  
Rahul K. Mukherjee ◽  
John Whitaker ◽  
Alkystis Phinikaridou ◽  
...  

Abstract Objective To develop a three-dimensional (3D) high-resolution free-breathing magnetization transfer ratio (MTR) sequence for contrast-free assessment of myocardial infarct and coronary vein anatomy. Materials and methods Two datasets with and without off-resonance magnetization transfer preparation were sequentially acquired to compute MTR. 2D image navigators enabled beat-to-beat translational and bin-to-bin non-rigid motion correction. Two different imaging sequences were explored. MTR scar localization was compared against 3D late gadolinium enhancement (LGE) in a porcine model of myocardial infarction. MTR variability across the left ventricle and vessel sharpness in the coronary veins were evaluated in healthy human subjects. Results A decrease in MTR was observed in areas with LGE in all pigs (non-infarct: 25.1 ± 1.7% vs infarct: 16.8 ± 1.9%). The average infarct volume overlap on MTR and LGE was 62.5 ± 19.2%. In humans, mean MTR in myocardium was between 37 and 40%. Spatial variability was between 15 and 20% of the mean value. 3D whole heart MT-prepared datasets enabled coronary vein visualization with up to 8% improved vessel sharpness for non-rigid compared to translational motion correction. Discussion MTR and LGE showed agreement in infarct detection and localization in a swine model. Free-breathing 3D MTR maps are feasible in humans but high spatial variability was observed. Further clinical studies are warranted.



2020 ◽  
pp. 084653711990046 ◽  
Author(s):  
Yasuhiro Yokota ◽  
Chika Takeda ◽  
Masafumi Kidoh ◽  
Seitaro Oda ◽  
Ryo Aoki ◽  
...  

Purpose: To evaluate the effects of deep learning reconstruction (DLR) in qualitative and quantitative image quality of non-contrast magnetic resonance coronary angiography (MRCA). Methods: Ten healthy volunteers underwent conventional MRCA (C-MRCA) and high-resolution (HR) MRCA on a 3T magnetic resonance imaging with a voxel size of 1.8 × 1.1 × 1.7 mm3 and 1.8 × 0.6 × 1.0 mm3, respectively, for C-MRCA and HR-MRCA. High-resolution magnetic resonance coronary angiography was also reconstructed with the DLR technique (DLR-HR-MRCA). We compared the contrast-to-noise ratio (CNR) and visual evaluation scores for vessel sharpness and traceability of proximal and distal coronary vessels on a 4-point scale among 3 image series. Results: The vascular CNR value on the C-MRCA and the DLR-HR-MRCA was significantly higher than that on the HR-MRCA in the proximal and distal coronary arteries (13.9 ± 6.4, 11.3 ± 4.4, and 7.8 ± 2.6 for C-MRCA, DLR-HR-MRCA, and HR-MRCA, P < .05, respectively). Mean visual evaluation scores for the vessel sharpness and traceability of proximal and distal coronary vessels were significantly higher on the HR-DLR-MRCA than the C-MRCA ( P < .05, respectively). Conclusion: Deep learning reconstruction significantly improved the CNR of coronary arteries on HR-MRCA, resulting in both higher visual image quality and better vessel traceability compared with C-MRCA.



2020 ◽  
Vol 61 (10) ◽  
pp. 1406-1413
Author(s):  
Kyu Sung Choi ◽  
Young Hun Choi ◽  
Jung-Eun Cheon ◽  
Woo Sun Kim ◽  
In One Kim

Background The image quality of abdominal magnetic resonance imaging (MRI) in children who cannot hold their breath has been severely impaired by motion artifacts. Purpose To evaluate the usefulness of T1-weighted (T1W) BLADE MRI for axial abdominal imaging in children who cannot hold their breath. Material and Methods Two different BLADE sequences, with and without an inversion recovery (IR-BLADE), were compared to conventional turbo-spin echo (TSE) with a high number of excitations in 18 consecutive patients who cannot hold their breath. Overall image quality, motion artifact, radial artifact, hepatic vessel sharpness, renal corticomedullary differentiation, and lesion conspicuity were retrospectively assessed by two radiologists, using 4- or 5-point scoring systems. Signal variations of each sequence were measured for a quantitative comparison. The acquisition times of the three sequences were compared. Results IR-BLADE and BLADE showed significantly improved overall image quality and reduced motion artifact compared with TSE. IR-BLADE showed significantly better hepatic vessel sharpness and corticomedullary differentiation compared to both BLADE and TSE. Radial artifacts were only observed on IR-BLADE and BLADE. In nine patients with lesions, there were no significant differences in lesion conspicuity among three sequences. Compared to TSE, both IR-BLADE and BLADE showed decreased signal variations in the liver and muscle, and an increased signal variation through air. The mean acquisition times for IR-BLADE, BLADE, and TSE were comparable. Conclusion Compared to the TSE sequence, T1W IR-BLADE for pediatric abdominal MRI resulted in improved image quality, tissue contrast with a diminished respiratory motion artifact, and a comparable acquisition time.