The influence of combined supply voltage parameters (bias voltage and voltage pulse amplitude) on efficiency of ozone synthesis in the negative pulsed corona discharge in oxygen was obtained. Pulse overvoltage led to intensification of discharge processes. Bias voltage applied during the discharge channel relaxation essentially increased the efficiency of ozone synthesis. It was established that the “optimal” bias voltage which provides maximum ozone generation doesn’t depend on voltage pulse amplitude, but depends on input oxygen concentration and generated ozone concentration.


2008 ◽  
Vol 1144 ◽  
Author(s):  
Gokhan Bakan ◽  
Adam Cywar ◽  
Cicek Boztug ◽  
Mustafa Bilal Akbulut ◽  
Helena Silva ◽  
...  

ABSTRACTNanocrystalline silicon (nc-Si) micro-bridges are melted and crystallized through Joule heating by applying high-amplitude short duration voltage pulses. Full crystallization of nc-Si bridges is achieved by adjusting the voltage-pulse amplitude and duration. If the applied pulse cannot deliver enough energy to the bridges, only surface texture modification is observed. On the contrary, if the pulse is not terminated after the entire bridge melts, molten silicon diffuses on to the contact pads and the bridge tapers in the middle. Melting of the bridges can be monitored through current-time (I-t) and voltage-time (V-t) measurements during the electrical stress. Conductance of the bridges is enhanced after the electrical stress.