volume control mode
Recently Published Documents


TOTAL DOCUMENTS

5
(FIVE YEARS 1)

H-INDEX

2
(FIVE YEARS 0)

2014 ◽  
Vol 29 (6) ◽  
pp. 1041-1045 ◽  
Author(s):  
Alberto Medina ◽  
Vicent Modesto-Alapont ◽  
Carlos Lobete ◽  
Silvia Vidal-Micó ◽  
Francisco Álvarez-Caro ◽  
...  

2004 ◽  
Vol 101 (3) ◽  
pp. 722-728 ◽  
Author(s):  
Yoshiko Maeda ◽  
Yuji Fujino ◽  
Akinori Uchiyama ◽  
Nariaki Matsuura ◽  
Takashi Mashimo ◽  
...  

Background A lung-protecting strategy is essential when ventilating acute lung injury/acute respiratory distress syndrome patients. Current emphasis is on limiting inspiratory pressure and volume. This study was designed to investigate the effect of peak inspiratory flow on lung injury. Methods Twenty-four rabbits were anesthetized, tracheostomized, ventilated with a Siemens Servo 300, and randomly assigned to three groups as follows: 1) the pressure regulated volume control group received pressure-regulated volume control mode with inspiratory time set at 20% of total cycle time, 2) the volume control with 20% inspiratory time group received volume-control mode with inspiratory time of 20% of total cycle time, and 3) the volume control with 50% inspiratory time group received volume-control mode with inspiratory time of 50% of total cycle time. Tidal volume was 30 ml/kg, respiratory rate was 20 breaths/min, and positive end-expiratory pressure was 0 cm H2O. After 6 h mechanical ventilation, the lungs were removed for histologic examination. Results When mechanical ventilation started, peak inspiratory flow was 28.8 +/- 1.4 l/min in the pressure regulated volume control group, 7.5 +/- 0.5 l/min in the volume control with 20% inspiratory time group, and 2.6 +/- 0.3 l/min in the volume control with 50% inspiratory time group. Plateau pressure did not differ significantly among the groups. Gradually during 6 h, Pao2 in the pressure regulated volume control group decreased from 688 +/- 39 to a significantly lower 304 +/- 199 mm Hg (P < 0.05) (mean +/- SD). The static compliance of the respiratory system for the pressure regulated volume control group also ended significantly lower after 6 h (P < 0.05). Wet to dry ratio for the pressure regulated volume control group was larger than for other groups (P < 0.05). Macroscopically and histologically, the lungs of the pressure regulated volume control group showed more injury than the other groups. Conclusion When an injurious tidal volume is delivered, the deterioration in gas exchange and respiratory mechanics, and lung injury appear to be marked at a high peak inspiratory flow.


Sign in / Sign up

Export Citation Format

Share Document