Cardiac Mapping and Imaging

2019 ◽  
pp. 824-832
Author(s):  
Sabine Ernst
Keyword(s):  
Author(s):  
Nicholas D. Skadsberg ◽  
Timothy G. Laske ◽  
Paul A. Iaizzo

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
D Lin ◽  
B Glover ◽  
J Colley ◽  
B Thibault ◽  
C.M Steinberg ◽  
...  

Abstract Background The EnSite Precision™ Cardiac Mapping System is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3-D maps of cardiac chambers. Objective The EnSite Precision™ Observational Study was designed to quantify and characterize the use of the EnSite Precision™ Cardiac Mapping System for mapping and ablation of cardiac arrhythmias in a real-world environment and to evaluate procedural and subsequent clinical outcomes. Methods 1065 patients were enrolled at 38 centers in the U.S. and Canada between 2017–2018. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedures using the EnSite Precision™ System. Results Of 989 patients who completed the protocol, a geometry was created in 936 (94.7%). Most initial maps were created using Automap (n=545, 67.0%) or a combination of Automap and manually mapping (n=151, 18.6%). Median time to create an initial map was 9.0 min (IQR 5.0–15.0), with a median number of used mapping points per minute of 92.7 (IQR 30.0–192.0). During ablation, AutoMark was used in 817 (82.6%) of procedures. The most frequent metrics for lesion color were Impedance Drop or Impedance Drop Percent (45.5% combined), time (23.9%) and average force (14.2%). At Canadian sites where LSI was an option, it was used as the color metric in 87 (45.8%) of cases (10.6% overall). The EnSite System was stable throughout 79.7% (n=788 of 989) of procedures. Factors affecting stability were respiratory change (n=88 of 989, 8.9%), patient movement (n=73, 7.4%), CS Positional Reference dislodgement (n=32, 3.2%), and cardioversion (n=19, 1.9%). Conscious sedation was used in 189 (19.1%) of patients. Acute success was reached based on the pre-defined endpoints for the procedure in 97.4% (n=963) of cases. Conclusion In a real-world study analysis, the EnSite Precision™ mapping system was associated with a high prevalence of acute procedural success, low mapping times, and high system stability. Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mohammad Paymard ◽  
Marc W. Deyell ◽  
Santabhanu Chakrabarti ◽  
Zachary W. Laksman ◽  
Jacob Larsen ◽  
...  

Abstract Background This is a rare and challenging case of Wolff–Parkinson–White syndrome due to a posteroseptal accessory pathway located in the coronary sinus diverticulum. It is often difficult to precisely locate this type of accessory pathway, and the ablation procedure could be associated with collateral damage to the neighbouring coronary arteries. Case Presentation The patient was a 49-year-old female with Wolff–Parkinson–White syndrome who was referred for catheter ablation. She had had a previous unsuccessful attempt at ablation and had remained symptomatic despite drug therapy. The pre-procedural cardiac computed tomography scan revealed the presence of a diverticulum in the proximal coronary sinus. Using an advanced three-dimensional cardiac mapping system, the electroanatomic map of the diverticulum was created. The accessory pathway potential was identified within the diverticulum preceding the ventricular insertion. The accessory pathway was then successfully ablated using radiofrequency energy. Conclusion We have demonstrated that the advanced three-dimensional cardiac mapping system plays a very important role in guiding clinicians in order to precisely locate and safely ablate this type of challenging accessory pathway.


2015 ◽  
Vol 7 (1) ◽  
pp. i ◽  
Author(s):  
Ashok J. Shah ◽  
Michel Haissaguerre ◽  
Meleze Hocini
Keyword(s):  

2012 ◽  
pp. 867-917
Author(s):  
Mohammad Shenasa ◽  
Shahriar Heidary ◽  
Javad Rahimian ◽  
Gerhard Hindricks
Keyword(s):  

2021 ◽  
Vol 118 (45) ◽  
pp. e2103979118
Author(s):  
Çağla Özsoy ◽  
Ali Özbek ◽  
Michael Reiss ◽  
Xosé Luís Deán-Ben ◽  
Daniel Razansky

Propagation of electromechanical waves in excitable heart muscles follows complex spatiotemporal patterns holding the key to understanding life-threatening arrhythmias and other cardiac conditions. Accurate volumetric mapping of cardiac wave propagation is currently hampered by fast heart motion, particularly in small model organisms. Here we demonstrate that ultrafast four-dimensional imaging of cardiac mechanical wave propagation in entire beating murine heart can be accomplished by sparse optoacoustic sensing with high contrast, ∼115-µm spatial and submillisecond temporal resolution. We extract accurate dispersion and phase velocity maps of the cardiac waves and reveal vortex-like patterns associated with mechanical phase singularities that occur during arrhythmic events induced via burst ventricular electric stimulation. The newly introduced cardiac mapping approach is a bold step toward deciphering the complex mechanisms underlying cardiac arrhythmias and enabling precise therapeutic interventions.