scholarly journals Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single‐institution experience

2019 ◽  
Vol 20 (10) ◽  
pp. 33-42
Author(s):  
You Zhang ◽  
Anh H. Le ◽  
Zhen Tian ◽  
Zohaib Iqbal ◽  
Tsuicheng Chiu ◽  
...  
2021 ◽  
Author(s):  
DaZhen Jiang ◽  
Dajiang Wang ◽  
Jiuling Shen ◽  
Jun Zhang ◽  
Cheng Chen ◽  
...  

Abstract ObjectiveThe objective of this study was to investigate accuracy of the United Imaging Healthcare's uRT treatment planning system (uRT-TPS), by creating AAPM TG 119 test plans with respectively IMRT and VMAT techniques by homogeneous and heterogeneous phantom. Materials and MethodsThe plans were delivered to the homogeneous and heterogeneous phantom using the United Imaging Healthcare's uRT-Linac 506C. The overall dose calculation accuracy by uRT-TPS with Collapsed Cone Convolution (CC) and Monte Carlo (MC) algorithm was measured and analyzed by creating IMRT and VMAT plans for the 5 test geometries specified in TG 119, by using two kinds of beams FF photon beam and FFF photon beam. The point doses were measured with a Farmer type ion chamber and the fluences were measured with films respectively. Results The result of position accuracy was shown that the worst position accuracy is 0.36 mm and the repeated positioning accuracy of MLC field location was less than 0.25mm. The symmetry deviation of MLC was less than 0.08mm. In this study, the CLs of sMLC, dMLC and VMAT plans with FF photon beams were 2.74%, 2.12%, and 1.36% respectively. As for FFF photon beams, they were 3.76%, 2.14% and 2.90% respectively, whereas the counterpart CL specified in TG119 were 4.5% for the high dose regions and 4.7% for OAR regions. The CLs of Gamma Passing rates for sMLC, dMLC and VMAT plans were 4.59%, 5.35% and 2.15% for FF beam mode, and were 1.82%, 6.12% and 4.82% for FFF beam mode. For the heterogeneous phantom, the maximum deviation is 2.35% for CC and 2.63% for MC algorithm respectively.Conclusion Based on this analysis which were performed in accordance with the TG 119 recommendations, it is evident that the URT treatment planning system and URT-Linac 506C have commissioned IMRT and VMAT techniques with adequate accuracy. and all uRT_TPS treatment plans were recognized as clinically acceptable.


2018 ◽  
Vol 24 (3) ◽  
pp. 109-114
Author(s):  
Habib Ahmad ◽  
Misbah Ahmad ◽  
Shahid Ali ◽  
M. Rauf Khattak ◽  
Wajeeha Shaheen ◽  
...  

Abstract The goal of radiotherapy is to deliver prescribed dose to the target volume and simultaneously minimize the dose to the healthy organs. The purpose of this work was to verify the accuracy of calculations carried out with a treatment planning system (TPS). Measurements carried out with thermoluminescence detectors (TLDs) were compared with doses calculated with TPS. Doses were measured and calculated both in the open beam’s region and under individual blocks. Measurements were performed in the Randophantom. The work was carried out for photon beams generated in the Varian CLINAC 2100C accelerator. The maximum / minimum percentage differences between measured and calculated doses were 4.9/0.6%, 2.6/0%, and 3.5%/0.5% in open, shielded and partially shielded points, respectively. Differences between the measured and calculated doses were within acceptable limits.


2011 ◽  
Vol 27 (3) ◽  
pp. 135-143 ◽  
Author(s):  
Wazir Muhammad ◽  
Muhammad Maqbool ◽  
Muhammad Shahid ◽  
Amjad Hussain ◽  
Sajjad Tahir ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document