Determination of imatinib mesylate and its main metabolite (CGP74588) in human plasma and murine specimens by ion-pairing reversed-phase high-performance liquid chromatography

2007 ◽  
Vol 21 (7) ◽  
pp. 747-754 ◽  
Author(s):  
Roos L. Oostendorp ◽  
Jos H. Beijnen ◽  
Jan H. M. Schellens ◽  
Olaf van Tellingen
2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


2002 ◽  
Vol 65 (4) ◽  
pp. 688-691 ◽  
Author(s):  
P. S. GONG ◽  
S. L. JENG ◽  
Y. F. HSU ◽  
C. C. LIN ◽  
S. Y. LIN

An ion-pairing reversed-phase high-performance liquid chromatography (HPLC) method with diode array detection at 280 nm was developed to determine pyrimethamine concentrations in feed for laying hens. Pyrimethamine was extracted with a mixture of 5% isobutanol and 95% benzene, and the extract was cleaned up on an alumina column. The drug was eluted from an Intersil ODS-3V column (250 by 4.6 mm) with a mixture of 25% acetonitrile and 75% water (vol/vol) containing 0.01 M tetramethylammonium chloride as an ion-pairing agent and adjusted with acetic acid to pH 3.5. The flow rate was 1.0 ml/min. Mean recovery of pyrimethamine from supplemented feeds at concentrations of 2, 4, and 5 μg/g of feed were 100.5, 103.5, and 100.8%, respectively. Precision within a day ranged from 4.3 to 7.0% for the three concentrations, and day-to-day precision was 5.3% for feed supplemented at a concentration of 4 μg/g. No chromatographic interference was detected from other 2,4-diaminopyrimidine compounds or other major drugs used in poultry.


Sign in / Sign up

Export Citation Format

Share Document