Incidence, treatment, and outcome of acute aortic valve regurgitation complicating percutaneous balloon aortic valvuloplasty

2015 ◽  
Vol 89 (4) ◽  
pp. E145-E152 ◽  
Author(s):  
Gianni Dall'Ara ◽  
Francesco Saia ◽  
Carolina Moretti ◽  
Cinzia Marrozzini ◽  
Nevio Taglieri ◽  
...  
2011 ◽  
Vol 79 (2) ◽  
pp. 315-321 ◽  
Author(s):  
Francesco Saia ◽  
Cinzia Marrozzini ◽  
Cristina Ciuca ◽  
Barbara Bordoni ◽  
Gianni Dall'Ara ◽  
...  

2019 ◽  
Vol 13 (2) ◽  
pp. 51-55
Author(s):  
Hussein A. Alwahab

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow . Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis . Type of the study: A prospective study. Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011. Results: Twenty seven patients were male (77.2%) and 8 patients were female (22.8%), male to female ratio 3.5/ 1, . The aortic valve was bicuspid in 18 patients (51.4%) while 17 patients ( 48.6%) had tricuspid aortic valve. Balloon aortic valvuloplasty was successful in 30 patients (85.7%),. Maximum peak instantaneous Doppler pressure gradient across the aortic valve 24 hours postprocedural echocardiography showed reduction which is statistically significant. New aortic regurgitation had occurred in 15 patients ( 42.8%), it was mild in 9 patients ( 25.6%), moderate in 5 patients ( 14.3%) and severe in 1 patient( 2.9%) which is statistically significant. The follow up of 12.57 ± 3.88 ( 3- 22) months after intervention was done for all patients using echocardiography Doppler study, reveal the maximum peak instantaneous Doppler pressure gradient  across the aortic valve was raised  which is statistically significant. The aortic regurgitation was present in 18 patients (51.4%) , it was mild in 9 patients (25.7%) , moderate in 6 patients (17.1%) and severe in 3 patients  ( 8.6%). No mortality had been reported during the procedure or on follow up.                                                                                  Conclusion: Aortic balloon valvuloplasty is safe and effective procedure in the treatment of congenital valvular aortic stenosis but mild aortic regurgitation is the most common immediate complication of aortic balloon dilatation and progressive aortic regurgitation is a major problem during the intermediate follow up.                                                                                                                                               


1970 ◽  
Vol 1 (2) ◽  
pp. 234-236
Author(s):  
AQM Reza ◽  
MSR Patwary ◽  
A Baqui

A 8 years old boy presented with shortness of breath, cough and palpitation and subsequently diagnosed as a case of severe aortic stenosis with bicuspid aortic valve. Percutaneous balloon aortic valvuloplasty (PBAV) was done and he became asymptomatic. Post procedure his aortic valve area and aortic systolic pressure increased, transaortic pressure gradient decreased. So good result, lower cost, elimination of drawbacks of thoracotomy and cardiopulmonary bypass suggest in children percutaneous balloon aortic valvuloplasty should be the treatment of choice for patients with severe aortic stenosis. Key Words: Percutaneous balloon aortic valvuloplasty, Severe aortic stenosis, Bicuspid aortic valve DOI: http://dx.doi.org/10.3329/cardio.v1i2.8241 Cardiovasc. j. 2009; 1(2): 234-236


Sign in / Sign up

Export Citation Format

Share Document