A hexapod robot external fixator for computer assisted fracture reduction and deformity correction

Author(s):  
K Seide ◽  
M Faschingbauer ◽  
M E Wenzl ◽  
N Weinrich ◽  
C Juergens
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yanshi Liu ◽  
Hong Li ◽  
Jialin Liu ◽  
Xingpeng Zhang ◽  
Maimaiaili Yushan ◽  
...  

Abstract Background The hexapod external fixator (HEF), such as the Taylor spatial frame (TSF), offering the ability of multidirectional deformities correction without changing the structure, whereas there are so many parameters for surgeons to measure and subjective errors will occur inevitably. The purpose of this study was to evaluate the effectiveness of a new method based on computer-assisted three-dimensional (3D) reconstruction and hexapod external fixator for long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. Methods This retrospective study consists of 25 patients with high-energy tibial diaphyseal fractures treated by the HEF at our institution from January 2016 to June 2018, including 22 males and 3 females with a mean age of 42 years (range 14–63 years). Hexapod external fixator treatments were conducted to manage the multiplanar posttraumatic deformities with/without poor soft-tissue that were not suitable for internal fixation. Computer-assisted 3D reconstruction and trajectory planning of the reduction by Mimics were applied to perform virtual fracture reduction and deformity correction. The electronic prescription derived from the length changes of the six struts were calculated by SolidWorks. Fracture reduction was conducted by adjusting the lengths of the six struts according to the electronic prescription. Effectiveness was evaluated by the standard anteroposterior (AP) and lateral X-rays after reduction. Results All patients acquired excellent functional reduction and achieved bone union in our study. After correction, the mean translation (1.0 ± 1.1 mm) and angulation (0.8 ± 1.2°) on the coronal plane, mean translation (0.8 ± 1.0 mm) and angulation (0.3 ± 0.8°) on the sagittal plane were all less than those (6.1 ± 4.9 mm, 5.2 ± 3.2°, 4.2 ± 3.5 mm, 4.0 ± 2.5°) before correction (P < 0.05). Conclusions The computer-assisted three-dimensional reconstruction and hexapod external fixator-based method allows surgeons to conduct long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. This method is suggested to apply in those unusually complex cases with extensive soft tissue damage and where internal fixation is impossible or inadvisable.


2020 ◽  
Author(s):  
Yanshi Liu ◽  
Hong Li ◽  
Jialin Liu ◽  
Xingpeng Zhang ◽  
Maimaiaili Yushan ◽  
...  

Abstract Background: The hexapod external fixator (HEF), such as the Taylor spatial frame (TSF), offering the ability of simultaneous correction of the multidirectional deformities without frame modification, whereas there are so many parameters for surgeons to measure and subjective errors will occur inevitably. The purpose of this study was to evaluate the effectiveness of a new method based on computer-assisted three-dimensional (3D) reconstruction and hexapod external fixator for long bone fracture reduction and deformity correction without calculating the parameters needed by the computer program.Methods: This retrospective study consists of 25 patients with high-energy tibial diaphyseal fractures treated by the HEF at our institution from January 2016 to June 2018, including 22 males and 3 females with a mean age of 42 years (range 14-63 years). Hexapod external fixator treatments were performed due to primary and definitive management of multiplanar posttraumatic deformity and/or severe soft-tissue damage that were not suitable for internal fixation in the tibia. Computer-assisted 3D reconstruction and trajectory planning of the reduction by Mimics were applied to perform virtual fracture reduction and deformity correction. The electronic prescription derived from the length changes of the six struts were calculated by SolidWorks. Fracture reduction was conducted by adjusting the lengths of the six struts according to the electronic prescription. The standard anteroposterior (AP) and lateral X-rays after reduction were taken to evaluate the effectiveness.Results: All patients acquired excellent functional reduction (most cases achieved anatomical reduction) in our study. The mean coronal plane translation (1.0±1.1 mm), coronal plane angulation (0.8±1.2°), sagittal plane translation (0.8±1.0 mm) and sagittal plane angulation (0.3±0.8°) after correction were all less than those (6.1±4.9 mm, 5.2±3.2°, 4.2±3.5 mm, 4.0±2.5°) before correction (P<0.05).Conclusion: The computer-assisted three-dimensional reconstruction and hexapod external fixator-based method allows surgeons to conduct long bone fracture reduction and deformity correction without calculating the parameters needed by the computer program. Considering the radiologic exposure, this method is suggested to apply in those unusually complex cases with extensive soft tissue damage and internal fixation is impossible or inadvisable.


2001 ◽  
Vol 6 (3) ◽  
pp. 153-159 ◽  
Author(s):  
T. Hüfner ◽  
T. Pohlemann ◽  
S. Tarte ◽  
A. Gänsslen ◽  
M. Citak ◽  
...  

2002 ◽  
Vol 399 ◽  
pp. 231-239 ◽  
Author(s):  
T. H??fner ◽  
T. Pohlemann ◽  
S. Tarte ◽  
A. G??nsslen ◽  
J. Geerling ◽  
...  

2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

UNSTRUCTURED The retrospective study of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures provides a theoretical basis for the application of this technology. The paper collected 28 patients with tibiofibular fractures from the Department of Orthopaedics in our hospital from March 2015 to June 2018. After the treatment, the follow-up evaluation of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. The results showed that Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. To this end, the thesis research can be concluded as follows: Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures, it is worthy of clinical promotion.


Sign in / Sign up

Export Citation Format

Share Document