Parameter Study of Synthetic-Aperture Focusing in Ultrasonics

Author(s):  
John Johnson
2004 ◽  
Vol 12 (04) ◽  
pp. 571-585
Author(s):  
L. MEDINA ◽  
E. MORENO

An algorithm has been developed to implement synthetic aperture focusing technique for B-scan. This is made at a several transmitter/receiver locations to form a map of ultrasonic reflectivity on the insonified region, considering the path travelled by the ultrasonic pulse from the transducer to the target and back again. To reconstruct the image, a time domain beam-former is applied to the envelope of the detected signals. This method minimizes the side-lobe amplitude and the restriction of λ/2 distance between two adjacent transducer positions can be neglected without loosing image resolution. The present work is focused on the location of the in-homogeneities, caused by the presence of a phantom immersed in a water tank. The results are presented when the distance between two adjacent transducer positions are varied from 0.5λ to 2.5λ showing that the longitudinal resolution is not affected but the lateral resolution becomes poorer when the distance is about 2λ. The error in the longitudinal location of in-homogeneities is within the minimum detectable distance of the system, while the lateral location error is increased when the distance between any two adjacent transducer positions is larger than 1.5λ.


2021 ◽  
Author(s):  
Hyunwoo Song ◽  
Jeeun Kang ◽  
Emad M. Boctor

In this paper, we present a novel analytical approach to optimize radial synthetic aperture focusing framework for high-definite and high-sensitive volumetric transrectal ultrasound imaging (TRUS-rSAF). A closed-form analytical description of beam profile defines spatial resolution and grating lobe positions in the TRUS-rSAF imaging of radial plane and validated by a heuristic testing of the critical parameters. Given the theoretical foundation, we optimize the TRUS-rSAF system configuration to balance the spatial and temporal resolution, grating lobe artifacts, and signal-to-noise ratio (SNR) in radial plane with a design criterion to outperform a clinical volumetric TRUS (TRUS-REF) imaging. The results showed that the proposed analytical optimization provides significant improvements of imaging quality in radial plane even over an in-plane microconvex TRUS imaging. Therefore, our analytical approach provides a optimal framework for effective TRUS-rSAF imaging in clinics.


2015 ◽  
Vol 13 (10) ◽  
pp. 101101-101104 ◽  
Author(s):  
De Cai De Cai ◽  
Zhongfei Li Zhongfei Li ◽  
Sung-Liang Chen Sung-Liang Chen

Sign in / Sign up

Export Citation Format

Share Document