Phacoemulsification and Posterior Chamber Intraocular Lens (IOL) Implantation

2018 ◽  
pp. 1358-1358
2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Norihiro Yamada ◽  
Takahiko Hayashi ◽  
Kentaro Yuda ◽  
Toshiki Shimizu ◽  
Itaru Oyakawa ◽  
...  

Purpose. To evaluate the clinical outcomes of Descemet membrane endothelial keratoplasty (DMEK) for vitrectomized eyes that underwent pars plana vitrectomy (PPV) and transscleral-sutured intraocular lens (IOL) implantation. Methods. In this retrospective study, DMEK cases were reviewed from medical records and divided into two groups: the eyes after PPV and transscleral-sutured IOL implantation (vitrectomized group) and the eyes with in-the-bag IOL implantation (control group) prior to DMEK. The main outcome measures included time of graft unfolding during surgery and best spectacle-corrected visual acuity (BSCVA), central corneal thickness (CCT), and endothelial cell density (ECD) at 1, 3, and 6 months after the DMEK. Results. Twenty-three eyes (vitrectomized group, n=8; control group, n=15) in 23 patients were included in this study. The unfolding time was significantly longer in the vitrectomized group than in the control group (P<0.001). Postoperative BSCVA was worse in the vitrectomized group (0.16 ± 0.15) than in the control group (−0.06 ± 0.06; P=0.017). The improvement in BSCVA was negatively correlated with the patients’ age and frequency of previous surgeries. Conclusions. Despite the longer graft unfolding time and limited visual recovery, DMEK should be applicable to vitrectomized eyes with transscleral-sutured IOL implantation.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Zhizhong Wu ◽  
Caijuan Liu ◽  
Yanhui Xu ◽  
Wei Dong ◽  
Zhimin Chen

Purpose. To evaluate the short-term safety and efficacy of a novel approach of utilizing the 9-0 looped polypropylene suture with double knots buried into the scleral groove and the scleral tunnel to minimize the risk of the suture erosion and suture knot exposure. Design. Clinical-based retrospective study. Methods. Records of consecutive patients who had anterior vitrectomy and scleral-fixated posterior chamber intraocular lens (IOL) implantation between July 2018 and April 2020 with a minimum follow-up of 3 months were reviewed. Results. This study enrolled a total of 21 eyes from 20 patients (15 male). These patients had a mean age of 58.52 ± 8.55 years and were followed for an average of 1.08 ± 0.58 years postoperatively. Best-corrected visual acuity (BCVA) improved from a preoperative mean of 0.43 ± 0.41 logMAR to a significantly higher mean 3-month postoperative value of 0.09 ± 0.21 logMAR (Z = -3.35, p < 0.01 ). There were no statistical differences between the preoperative and postoperative corneal endothelial cell density ( p = 0.71 ). The postoperative complications included transient increased intraocular pressure in 5 eyes (24%). No other complications were detected during the follow-up. Conclusions. The modified technique proposed is a safe, effective, and reliable approach resulting in good visual outcomes. Our procedure might have the potential benefit to avoid suture-related complications in scleral-fixated IOL implantation. Trial registration. Retrospective case series study, not applicable.


2009 ◽  
Vol 7 (2) ◽  
pp. 56-59 ◽  
Author(s):  
Christopher J. A. Baddon ◽  
Gabor G.B. Scharioth ◽  
Som Prasad

2021 ◽  
pp. 247412642097887
Author(s):  
Gregg T. Kokame ◽  
Tarin T. Tanji ◽  
Jase N. Omizo

Purpose: We report the longest follow-up to our knowledge of stable scleral fixation of a posterior chamber intraocular lens (PC IOL) with 10-0 polypropylene sutures. Methods: A retrospective review is presented of a case with more than 30 years’ follow-up after performing sutured scleral fixation with 10-0 polypropylene suture using 2 sutures tied together under a scleral flap. One suture was a cow-hitch looped around the haptic, and the other suture was passed through the sclera to create the scleral fixation. Results: The scleral fixation with 10-0 polypropylene suture knots for both haptics of the PC IOL allowed central optic positioning with excellent vision for more than 30 years without suture breakage. Conclusions: Polypropylene sutures for scleral fixation of PC IOLs remained stable for more than 30 years with central positioning of the PC IOL, without exposure of the fixation suture knots through the conjunctiva, and without suture breakage.


Sign in / Sign up

Export Citation Format

Share Document