posterior chamber
Recently Published Documents


TOTAL DOCUMENTS

1615
(FIVE YEARS 230)

H-INDEX

65
(FIVE YEARS 8)

2022 ◽  
Vol 7 (4) ◽  
pp. 619-623
Author(s):  
Kartika Anand ◽  
Ashutosh Dokania

To evaluate changes in macular thickness via-a-vis visual acuity post uncomplicated manual small incision cataract surgery (MSICS) & phacoemulsification surgery Prospective clinical study on 160 patients of uncomplicated immature senile cataract, aged 40-70yrs, patients were randomised into two groups, MSICS & phacoemulsification, by simple 1:1 randomization, who underwent uncomplicated cataract surgery with posterior chamber intraocular lens (PCIOL). Post-operatively, the patients were evaluated for best corrected visual acuity (BCVA) and changes in macular thickness by optical coherence tomography (OCT) at post-op Day 1, 7, 21, 48, and 12 weeks. Paired t-test was used for comparison across follow up. : At 12 weeks post-operative, mean logMAR BCVA was 0.01±0.02 for MSICS group and 0±0.02 for Phacoemulsification group. Macular thickness was not statistically significant (p=0.342) between MSICS group (219.19±17.88µm) and Phacoemlusification group (215.61±16.21µm), at the end of 12 weeks post-operative. Clinically significant macular oedema was not diagnosed in any of the patients at the follow-ups.: Both procedures achieved good post-operative Best Corrected visual acuity without significant differences in BCVA between both the groups at the end of 12 weeks.


2021 ◽  
Vol 6 (6-1) ◽  
pp. 204-213
Author(s):  
M. M. Bikbov ◽  
O. I. Orenburkina ◽  
A. E. Babushkin ◽  
I. F. Nuriev

Keratoconus (KC) is a progressive degenerative corneal disease, leads to the aberration of biomechanical and optical properties and thinning of the cornea, causes astigmatism and decreases visual acuity.Materials and methods. 33 patients (35 eyes) with stages II–III of non-progressive keratoconus and concomitant cataracts of various stages of maturity were operated on. The average age of the patients was 46.5 ± 2.7 (41–63) years old. The operations were performed according to our proposed two-stage method of treating ametropia in patients with KC and cataracts (Patent of the Russian Federation No. 2748634 of 28.05.2021). The first stage was the implantation of FERRARA intrastromal corneal ring segments (ICRS) with thickness from 150 to 350 μm. To correct residual refractive error in 5–7 months after stage 1, patients underwent stage 2: cloudy lens was removed and replaced with toric posterior chamber intraocular lens (TIOL) – AcrySof IQ Toric (Alcon, USA), T-fl ex Toric RayOne (Rayner, UK).Results and discussion. After stage 1 of the operation (ICRS implantation), the uncorrected visual acuity (NCVA) was 0.2 ± 0.03, the best corrected visual acuity (BCVA) was 0.4 ± 0.02. In 1 month after stage 2 (phacoemulsifi cation + TIOL) NCVA was 0.64 ± 0.11 and BCVA was 0.74 ± 0.12. During the entire follow-up period after the surgery visual functions, refraction, and rotational stability of TIOL were stable.Conclusions. Conducting a two-stage surgical intervention in patients with keratoconus and cataracts allows to stop the progression of the disease and effectively correct the ametropia concomitant with keratoconus.


2021 ◽  
Vol 12 (1) ◽  
pp. 11
Author(s):  
Chen Xin ◽  
Xiaofei Wang ◽  
Ningli Wang ◽  
Ruikang Wang ◽  
Murray Johnstone

Trabecular meshwork (TM) motion abnormality is the leading cause of glaucoma. With technique limitations, how TM moves is still an enigma. This study describes a new laboratory platform to investigate TM motion responses to ocular transients in ex vivo eyes. The anterior segments of human cadaver and primate eyes were mounted in a perfusion system fitting. Perfusion needles were placed to establish mean baseline pressure. A perfusion pump was connected to the posterior chamber and generated an immediate transient pressure elevation. A phase-sensitive optical coherent tomography system imaged and quantified the TM motion. The peak-to-peak TM displacements (ppTMD) were determined, a tissue relaxation curve derived, and a time constant obtained. This study showed that the ppTMD increased with a rise in the pulse amplitude. The ppTMD was highest for the lowest mean pressure of 16 mmHg and decreased with mean pressure increase. The pulse frequency did not significantly change ppTMD. With a fixed pulse amplitude, an increase in mean pressure significantly reduced the time constant of recoil from maximum distension. Our research platform permitted quantitation of TM motion responses to designed pulse transients. Our findings may improve the interpretation of new TM motion measurements in clinic, aiding in understanding mechanisms and management.


2021 ◽  
Vol 8 ◽  
Author(s):  
Kazutaka Kamiya ◽  
Kimiya Shimizu ◽  
Masahide Takahashi ◽  
Wakako Ando ◽  
Hideki Hayakawa ◽  
...  

Purpose: To assess the 8-year clinical outcomes of implantation of an implantable collamer lens (ICL) with a central port (KS-Aquaport; EVO-ICL) for moderate to high myopia and myopic astigmatism.Methods: This retrospective study comprised a total of 177 eyes of 106 patients with spherical equivalents of −7.99 ± 3.33 D [mean ± standard deviation], who underwent EVO-ICL implantation. We evaluated the safety, efficacy, predictability, stability, and adverse events of the surgery, at 1 month, and 1, 2, 4, 6, and 8 years postoperatively.Results: The logarithm of the minimal angle of resolution (LogMAR) uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were −0.07 ± 0.17 and −0.20 ± 0.09, respectively, at 8 years postoperatively. The safety and efficacy indices were 1.18 ± 0.24 and 0.89 ± 0.28, respectively. At 8 years, 83 and 93% eyes were within ± 0.5 D and ± 1.0 D of the targeted correction, respectively. Change in manifest refraction from 1 month to 8 years postoperatively was −0.13 ± 0.30 D. Three eyes (1.7%) that developed cataracts had a slight pre-existing peripheral anterior subcapsular cataract formation required simultaneous ICL extraction and cataract surgery at 2 or 3 years or ICL size change (1 size up) at 7 years postoperatively. We found that neither significant intraocular pressure (IOP) rise (including pupillary block) nor significant endothelial cell loss occurred in any case throughout the 8-year observation period.Conclusions: Current ICL implantation with central port technology offered good continuous outcomes for all measures of safety, efficacy, predictability, and stability for correcting moderate to high myopic errors over a long period, thereby suggesting its long-term viability as a surgical approach for the treatment of such eyes.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 292-305
Author(s):  
Pedro Serra ◽  
Ángel Sánchez Trancón ◽  
Oscar Torrado Sierra ◽  
António Baptista ◽  
Santiago Cerpa Manito

Posterior chamber phakic intraocular lens implantation is a refractive technique for the correction of myopia. This study aimed to identify those factors contributing to variability in postoperative refraction. Methods: This retrospective study evaluated 73 eyes (one eye per patient) implanted with myopic implantable collamer lenses (ICL). Eyes were divided into two groups, the low myopic group (LMG) (ICL > −9.5 DS) and the high myopic group (HMG) (ICL ≤ −9.5 DS), to compare the predictability, efficacy index, and postoperative refraction between groups. The association of postoperative refraction with anatomical, demographic, and optical features was assessed through correlation analysis and investigated using ray-tracing. Results: Postoperative refraction at 3 months for the whole group was close to emmetropia at −0.02 ± 0.37 DS, the LMG tended toward myopia and the HMG, toward hyperopia. The results showed that 65% and 54% of the eyes had postoperative refraction of within ±0.25 DS, respectively, in the LMG and HMG, and in both groups, 100% were within ±1.00 DS. ICL implantation had a higher efficacy index in the HMG (1.13 ± 0.15) than in the LMG (1.04 ± 0.15). Postoperative refraction was positively associated with the vault (R = 0.408) and negatively correlated with ICL power (R = −0.382). Conclusion: The predictability and effectiveness of ICL implantation is high in a wide range of myopias. Considering the expected vault and including accurate vertex measurements would contribute to improving the predictability of the results.


Zootaxa ◽  
2021 ◽  
Vol 5081 (4) ◽  
pp. 551-565
Author(s):  
YENGKHOM CHINGLEMBA ◽  
YUMNAM RAMESHORI ◽  
WAIKHOM VISHWANATH

Mustura taretensis, a new nemacheilid loach, is described from the Taret River, a tributary of the Yu River, Chindwin River drainage, Manipur, India. The new species is distinguished from all its congeners by a unique combination of the following characters: body with 12–13 irregular dark-brown blotches or bars on flank, alternating with 11–16 irregular dark-brown saddles on the back; dorsum of head with a distinctly visible rhomboid dark-brown mark encircling a pale oval area on the nape; dorsal fin with 9½­ or 10½ branched rays; lateral line complete; a well-developed free posterior chamber of air bladder, the halves of air bladder capsules connected by a manubrium; poorly developed processus dentiformis; suborbital flap present in males; and body depth 12.8–16.0 % SL. The generic status of Mustura chindwinensis, M. dikrongensis, M. tigrina and M. tuivaiensis are also discussed in the paper.  


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Evdoxia-Maria Karasavvidou ◽  
Craig Wilde ◽  
Anwar Zaman ◽  
Gavin Orr ◽  
Dharmalingam Kumudhan ◽  
...  

There are several available options for the demanding surgical correction of paediatric aphakia without sufficient capsular support. The literature suggests the implantation of a transscleral fixated posterior chamber-intraocular lens (PCIOL), an intrascleral fixated PCIOL, an iris-sutured intraocular lens (IOL), or an anterior chamber iris-claw IOL. We searched for reports on the management of paediatric aphakia in case of inadequate capsular support that delineated the diverse surgical approaches and their postoperative results. Analysis demonstrated that different complications can be encountered depending on IOL placement technique, such as suture rupture, IOL dislocation, secondary glaucoma, endophthalmitis, vitreous hemorrhage, and endothelial cell loss. However, it was shown that various IOL designs have similar visual outcomes. Taking into consideration the advantages and disadvantages of each surgical technique, ophthalmic surgeons can determine the safest and most efficient approach for paediatric aphakic patients.


2021 ◽  
Vol 49 (12) ◽  
pp. 030006052110609
Author(s):  
Jing Yang ◽  
Zhirong Wang ◽  
Qianzhong Cao ◽  
Yiyao Wang ◽  
Jieyi Wu ◽  
...  

Objective To assess a new method to measure the distance of the needle passage from the ciliary sulcus to the corneal limbus anterior border (CTC) in eyes with ectopia lentis directly in vivo via endoscopy and to further evaluate the correlations among the CTC, age, automated horizontal white-to-white distance (WTW), and ocular axial length (AL). Methods The WTW and AL were measured using an optical biometer. An intraocular endoscope was used during transscleral suture fixation of posterior chamber intraocular lenses to identify the true location of the ciliary sulcus. Linear regression analysis was used to assess the correlation between the CTC and other ocular biological parameters, including age, WTW, and AL. Results Thirty eyes of 30 children with ectopia lentis were evaluated. A statistically significant correlation was found between age and the CTC. The CTC could be predicted by the equation CTC = 0.1313 × Age + 0.9666. No statistically significant correlations were found between CTC and WTW, CTC and AL, WTW and AL, or WTW and age. Conclusion Endoscopy is useful for precisely suturing intraocular lens haptics in the real ciliary sulcus. Age can be used as an equivalent parameter for prediction of the true ciliary sulcus location.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Anjian Wang ◽  
Qi Fan ◽  
Yongxiang Jiang ◽  
Yi Lu

Abstract Objective We investigated the long-term visual outcomes and ocular complications of primary scleral-fixated posterior chamber intraocular lenses (SF-PC-IOLs) in patients with congenital lens subluxation. Methods We enrolled 53 patients (77 eyes) with congenital lens subluxation caused by ectopia lentis, Marfan syndrome, and Weill–Marchesani syndrome who underwent primary implantation of a SF-PC-IOL. All patients underwent a complete ophthalmic examination include visual acuity (VA), intraocular pressure (IOP), intraocular lenses (IOL) position, intraoperative complications and postoperative complications. Cox regression analysis and survival analysis were used to evaluate the risk factors for postoperative complications. Results Seventy seven eyes from 53 patients were included. Mean age at surgery was 23 ± 20 years (5 to 67 years), with a mean follow-up of 39 ± 27 months (12 to 130 months). The best-corrected VA improved from 0.84 ± 0.55 to 0.26 ± 0.43 logarithms of the minimum angle of resolution (p < 0.001). Best-corrected VA improved postoperatively in 73 eyes (94%). The main causes of reduced vision after surgery were retinal pathologies and amblyopia. Complications included transient intraocular haemorrhage (2 eyes, 2.6%), early vitreous incarceration (2 eyes, 2.6%), retinal detachment (6 eyes, 7.8%) and IOL dislocation (3 eyes, 3.9%). Cox regression showed that postoperative eye trauma was a risk factor for long-term postoperative complications. Conclusion SF-PC-IOLs provide good visual outcomes in patients with congenital lens subluxation. The SF-PC-IOLs showed good stability, except in patients suffering from postsurgical eye trauma.


2021 ◽  
pp. 112067212110620
Author(s):  
Aditya Kelkar ◽  
Jai Kelkar ◽  
Yogesh Chougule ◽  
Mounika Bolisetty ◽  
Priyanka Singhvi

Purpose To compare the surgical workload, complications, and visual outcomes using the three-dimensional visualization system with the conventional microscope in phacoemulsification cataract surgery. Design Prospective, non-randomized, open-label interventional study. Methods All patients underwent phacoemulsification cataract surgery using the three-dimensional visualization system or conventional microscope. Results Of the 203 eyes, 80 underwent surgery with the three-dimensional system while 123 underwent with the conventional microscope. No difference was noted in the total surgical duration, complication rates, and visual outcomes between the two groups. However, capsulorhexis was significantly faster using the conventional microscope while posterior chamber intraocular lens insertion was quicker using the three-dimensional system. In terms of cognitive workload comparison, no difference was seen in the surgeons’ heart rate, oxygen saturation levels, and surgery task load index total workload score and workload score for all six dimensions of the questionnaire, between the three-dimensional system and conventional microscope groups. As compared to baseline, the heart rate increased significantly during all surgical steps and at the end in both groups. When compared to baseline, the oxygen saturation levels were significantly raised during capsulorhexis, irrigation, and aspiration and posterior chamber intraocular lens insertion and at the end of the surgery in the three-dimensional group and during incision and at the end of the surgery in the conventional microscope group. Conclusions The duration of surgery, complications, and visual acuity outcomes remain unaffected while performing phacoemulsification cataract surgeries with the three-dimensional viewing system when compared to the conventional microscopes. Moreover, the surgeons’ cognitive workload too remains unaffected while utilizing this revolutionary three-dimensional surgical technology.


Sign in / Sign up

Export Citation Format

Share Document