Activity of Some Mixed Function Oxidases in Prenatally Carbon Disulphide (CS2) Treated Rats

Author(s):  
B. Nikiforov ◽  
S. Tabacova
1980 ◽  
Vol 188 (1) ◽  
pp. 107-112 ◽  
Author(s):  
Maria J. Obrebska ◽  
Peter Kentish ◽  
Dennis V. Parke

An intraperitoneal dose of CS2 (500mg/kg) to male rats resulted in loss of liver microsomal mixed-function-oxidase activity (85% loss of biphenyl 4-hydroxylase), followed by denaturation of liver cytochrome P-450 to cytochrome P-420, and degradative loss of both cytochromes (50% loss). Losses of NADPH–cytochrome c reductase (20%) and cytochrome b5 were considerably less. Intraperitoneal administration of CS2 (100mg/kg) to rats pretreated wtih phenobarbitone or 3-methylcholanthrene resulted in similar losses, but the rate of destruction was greater with cytochrome P-450 than with cytochrome P-448. At 12h after intraperitoneal injection of CS2 to non-pretreated rats, a new cytochrome (P-448) appeared. Rat liver microsomal preparations incubated with CS2 in the presence of NADPH and O2 resulted in loss of cytochrome P-450 and mixed-function-oxidase activity directly related to the concentration of CS2 (10–100μm) and to the period of incubation. Addition of EDTA (1mm) completely inhibited this destruction of cytochrome P-450 by CS2in vitro. Addition of CS2 to liver microsomal preparations resulted in moderate increases in the Ks values for type-I or type-II substrates, but these were insufficient to account for the inhibition of the mixed-function oxidases. We therefore suggest that desulphuration of CS2 leads to binding of the S to cytochrome P-450, denaturation of cytochrome P-450 to cytochrome P-420, and ultimately to destruction of these cytochromes by autoxidation.


1883 ◽  
Vol 16 (416supp) ◽  
pp. 6641-6641
Author(s):  
S. V. Wroblewski ◽  
K Olszewski
Keyword(s):  

1983 ◽  
Vol 48 (3) ◽  
pp. 722-734
Author(s):  
Martin Koval

The flame ionisation detector response to C6-C11 aliphatic hydrocarbon solutions in carbon disulphide in the concentration range between 1.3-9.5 mg ml-1 retained lineary despite the excess of solvent entering the detector simultaneously with the analyte. Pure carbon disulphide exhibited a small positive detector response which did not interfere in calibration procedure and which, under certain GC conditions, inverted to negative values. This response was not proportional to the injected volume and was strongly influenced by the column temperature and/or bleed. On the basis of these findings, a method compatible with the widely used charcoal tube carbon disulphide desorption procedure was developed and evaluated. It consists of static desorption of the sum of aliphatic alkanes and cycloalkanes from the activated charcoal after which an internal standard is added to the supernatant eluate. The resulting carbon disulphide solution is analysed on a highly polar stationary phase 1,2,3-tris(2-cyanoethoxy)propane where the solvent and the analyte coelute in a single peak, the height of which is practically proportional to the sum of alkanes and cycloalkanes present. This also makes determinations of other substances present in the sample more simple. The field test of the proposed method yielded values comparable in precision and accuracy with a control infrared spectrophotometric method.


1981 ◽  
Vol 46 (6) ◽  
pp. 1332-1347 ◽  
Author(s):  
Martin Koval

The described method uses activated charcoal sampling tubes for air sampling. Adsorbed compounds are eluted by the static desorption procedure with 1 ml of carbon disulphide, 0.5 ml of the supernatant is filtered off and, after internal standard addition, analysed on a gas chromatograph. Using synthetic calibration mixtures of model organic compounds with air, cumulative sampling and desorption efficiencies for 24 substances were determined for concentration ranges and sample volumes according to current Czechoslovak hygienic standards. Experimental results were treated with the single factor analysis of variance and the precision of the described procedure was estimated for the studied model compounds on the basis of residual sums of squares. Calculated values of cumulative sampling and desorption efficiencies and their precisions were compared with available published data and an acceptable agreement was found. In addition to that, cumulative sampling and desorption efficiencies were also found to be significantly correlated to molar volumes and other related molecular properties for some types of compounds.


Nature ◽  
1931 ◽  
Vol 128 (3238) ◽  
pp. 871-872 ◽  
Author(s):  
M. WOLFKE ◽  
J. MAZUR

Sign in / Sign up

Export Citation Format

Share Document