Changes in the Cerebrospinal Fluid Pressure After Intrathecal Injection of Contrast Media in Rabbits

1982 ◽  
pp. 159-163 ◽  
Author(s):  
B. Carlborg ◽  
P. Maly ◽  
K. Golman ◽  
T. Almén ◽  
C. Lindqvist
PLoS ONE ◽  
2014 ◽  
Vol 9 (8) ◽  
pp. e104267 ◽  
Author(s):  
Ya Xing Wang ◽  
Jost B. Jonas ◽  
Ningli Wang ◽  
Qi Sheng You ◽  
Diya Yang ◽  
...  

1986 ◽  
Vol 17 (02) ◽  
pp. 100-102 ◽  
Author(s):  
A. Kaiser ◽  
A. G. Whitelaw

1994 ◽  
Vol 58 (1) ◽  
pp. 112-115 ◽  
Author(s):  
Shigeru Kazama ◽  
Yoshihiko Masaki ◽  
Shigeyoshi Maruyama ◽  
Akira Ishihara

1985 ◽  
Vol 66 (6) ◽  
pp. 419-421
Author(s):  
A. A. Ashman

Literature data on the value of cerebrospinal fluid pressure in certain forms of ischemic stroke are few and contradictory.


2021 ◽  
pp. 197140092110551
Author(s):  
Robert Heider ◽  
Peter G Kranz ◽  
Erin Hope Weant ◽  
Linda Gray ◽  
Timothy J Amrhein

Rationale and Objectives Accurate cerebrospinal fluid (CSF) pressure measurements are critical for diagnosis and treatment of pathologic processes involving the central nervous system. Measuring opening CSF pressure using an analog device takes several minutes, which can be burdensome in a busy practice. The purpose of this study was to compare accuracy of a digital pressure measurement device with analog manometry, the reference gold standard. Secondary purpose included an assessment of possible time savings. Materials and Methods This study was a retrospective, cross-sectional investigation of 71 patients who underwent image-guided lumbar puncture (LP) with opening CSF pressure measurement at a single institution from June 2019 to September 2019. Exclusion criteria were examinations without complete data for both the digital and analog measurements or without recorded needle gauge. All included LPs and CSF pressures were measured with the patient in the left lateral decubitus position, legs extended. Acquired data included (1) digital and analog CSF pressures and (2) time required to measure CSF pressure. Results A total of 56 procedures were analyzed in 55 patients. There was no significant difference in mean CSF pressures between devices: 22.5 cm H2O digitally vs 23.1 analog ( p = .7). Use of the digital manometer resulted in a time savings of 6 min (438 s analog vs 78 s digital, p < .001). Conclusion Cerebrospinal fluid pressure measurements obtained with digital manometry demonstrate comparable accuracy to the reference standard of analog manometry, with an average time savings of approximately 6 min per case.


Sign in / Sign up

Export Citation Format

Share Document