Aortic Valve Reconstruction to Treat Aortic Stenosis Using Autologous Pericardium: Ozaki Procedure

2019 ◽  
pp. 177-184
Author(s):  
Shigeyuki Ozaki
2015 ◽  
Vol 79 (7) ◽  
pp. 1504-1510 ◽  
Author(s):  
Shigeyuki Ozaki ◽  
Isamu Kawase ◽  
Hiromasa Yamashita ◽  
Shin Uchida ◽  
Mikio Takatoh ◽  
...  

2021 ◽  

Replacements for diseased aortic valves are limited. Repair of the aortic valve is performed by only a few surgeons. A novel technique of aortic valve reconstruction using autologous pericardium shows promising results. In this video tutorial, we demonstrate the Ozaki procedure using an ex vivo low fidelity simulation.


ASVIDE ◽  
2019 ◽  
Vol 6 ◽  
pp. 173-173
Author(s):  
Dinh H. Nguyen ◽  
Anh T. Vo ◽  
Trang T. Nguyen ◽  
Khoi M. Le ◽  
Binh Q. Truong ◽  
...  

2019 ◽  
Vol 8 (3) ◽  
pp. 444-446
Author(s):  
Dinh H. Nguyen ◽  
Anh T. Vo ◽  
Trang T. Nguyen ◽  
Khoi M. Le ◽  
Binh Q. Truong ◽  
...  

2013 ◽  
Vol 16 (6) ◽  
pp. 738-742 ◽  
Author(s):  
Isamu Kawase ◽  
Shigeyuki Ozaki ◽  
Hiromasa Yamashita ◽  
Shin Uchida ◽  
Yukinari Nozawa ◽  
...  

2018 ◽  
Vol 86 (1) ◽  
pp. 49-50
Author(s):  
Guillermo Vaccarino ◽  
Cristian Kreutzer ◽  
Daniel Killinger ◽  
Benjamin Chiostri ◽  
Christian Gil ◽  
...  

2016 ◽  
Vol 20 (3) ◽  
pp. 26 ◽  
Author(s):  
E V Rosseykin ◽  
V V Bazylev ◽  
P A Batrakov ◽  
V A Karnakhin ◽  
A A Rastorguev

<p><strong>Aim.</strong> The study was designed to compare the immediate echocardiographic characteristics of aortic valve reconstruction by using autologous pericardium and the method proposed in 2007 by Shigeyuki Ozaki, as well as aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.<br /><strong>Methods.</strong> Over a period from January 2014 to February 2016, 76 patients underwent aortic valve replacement by means of frame-mounted biological prostheses Medtronic HANCOCK®II T505 CINCH® II (n=41) and Carpentier-Edwards PERIMOUNT (n=35) at our hospital. 20 patients underwent the Ozaki procedure. These three groups of patients were assigned to the study. Demographic and preoperative indicators of patients from all three groups were homogeneous (р&gt;0.05). The evaluation of the aortic valves replaced was carried out by echocardiography.<br /><strong>Results.</strong> Echocardiography was performed before the procedure and in the early postoperative period. Statistical analysis using ANOVA showed significantly lower values of the aortic valve pressure gradient (p&lt;0.001) and larger effective orifice area and indexed effective orifice area of the valve (p&lt;0.001) in the group of the Ozaki procedure.<br /><strong>Conclusion</strong>. According to echocardiography data, in the immediate postoperative period the Ozaki procedure is associated with lower mean and peak gradients of pressure on the aortic valve and larger effective orifice area and indexed effective orifice area of the valve, as compared with the frame-mounted biological aortic prostheses Medtronic HANCOCK®II T505 CINCH® II and the Carpentier-Edwards PERIMOUNT.<br /><br />Received 27 May 2016. Accepted 24 June 2016.</p><p><strong>Funding:</strong> The study had no sponsorship. <br /><strong>Conflict of interest:</strong> The authors declare no conflict of interest.</p>


2020 ◽  
Vol 66 (2-3) ◽  
pp. 69-74
Author(s):  
S.V. Varbanets ◽  
◽  
O.S. Gurjeva ◽  
O.Yu. Pukas ◽  
V.V. Payuk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document