Techno-Socio-Economic Sizing of Solar–Diesel Generator-Based Autonomous Power System Using Butterfly-PSO

2021 ◽  
pp. 427-437
Author(s):  
Priyanka Paliwal
2018 ◽  
Vol 42 (5) ◽  
pp. 411-435 ◽  
Author(s):  
Sergey N Udalov ◽  
Andrey A Achitaev ◽  
Alexander G Pristup ◽  
Boris M Bochenkov ◽  
Yuri Pankratz ◽  
...  

The paper is devoted to investigations of dynamic processes in a local power system consisting of wind turbines with a magnetic continuously variable transmission. Due to low inertia of wind turbine generator rotors, there is a problem of ensuring dynamic stability at sharp load changes or at short circuits in an autonomous power system. To increase dynamic stability of the system, two algorithms for controlling a magnetic continuously variable transmission are presented. The first algorithm stabilizes a rotation speed of the high-speed rotor of a magnetic continuously variable transmission from the generator side in a local power system consisting of wind turbines with uniform synchronous generators with permanent magnets having equal moments of inertia. Undoubtedly, local power systems having only the wind turbines with equal mechanical inertia time constants are not widely used due to stochastic nature of wind energy. Therefore, wind power systems are combined with a diesel generator or a gas-turbine unit. Investigations show that the use of the only speed stabilization algorithm is not enough for such power systems, because there is a possibility for occurrence of asynchronous operation under specific power changes due to the difference in moments of inertia of generator rotors. Thus, the second algorithm uses the phase shift compensation in accordance with a primary generator in an autonomous power system consisting of non-uniform generators having different mechanical inertia time constants. As a primary generator, a diesel generator or a gas-turbine unit having a primary speed controller may be used. It should be noted that algorithms of stabilization for speed and phase angle are extended by an inertial circuit of aerodynamic compensation for torque of rotation from the wind turbine side to reduce loading on an energy storage unit of the magnetic continuously variable transmission at disturbances from the generator side and the turbine side.


Author(s):  
С.Е. Кузнецов ◽  
Н.А. Алексеев ◽  
А.А. Виноградов

Изложена методика расчета показателей безотказности электроснабжения (вероятности безотказного электроснабжения и средней наработки до отказа) ответственных приемников морского судна, подключаемых к аварийному электрораспределительному щиту. Методика реализована применительно к судовой электроэнергетической системе с тремя источниками электроэнергии – двумя основными дизель-генераторными агрегатами, подключенными к главному электрораспределительному щиту, и одним аварийным дизель-генераторным агрегатом, подключенным к аварийному электрораспределительному щиту. Рассмотрены различные режимы работы судовой электроэнергетической системы: при работе до первого отказа одного основного дизель-генератора, при параллельной работе двух основных дизель-генераторов, при работе одного аварийного дизель-генератора; а также после обесточивания с учетом возможности последующего включения резервного или (и) аварийного дизель генератора. Методика, с соответствующими корректировками, может быть использована для расчета показателей безотказного электроснабжения в судовых электроэнергетических системах другой комплектации. Расчет показателей безотказности электроснабжения необходим при проектировании для обеспечения требуемого уровня надежности электроснабжения судовых приемников электроэнергии, а при эксплуатации – для предупреждения отказов и планирования технического обслуживания и ремонта элементов судовых электроэнергетических систем. The methodology for calculating the indicators of the reliability of power supply (the probability of failure-free power supply and the mean time to failure) of critical receivers of a sea vessel connected to the emergency electrical switchboard is presented. The technique is implemented in relation to a ship power system with three sources of electricity - two main diesel generator sets connected to the main electrical switchboard, and one emergency diesel generator set connected to an emergency electrical switchboard. Various operating modes of the ship's electric power system are considered: during operation until the first failure of one main diesel generator, during parallel operation of two main diesel generators, during operation of one emergency diesel generator; as well as after de-energizing, taking into account the possibility of subsequent switching on of the backup and / or emergency diesel generator. The technique, with appropriate adjustments, can be used to calculate indicators of reliable power supply in ship power systems of a different configuration. Calculation of power supply reliability indicators is necessary during design to ensure the required level of power supply reliability for ship power receivers, and during operation - to prevent failures and plan maintenance and repair of elements of ship power systems.


2017 ◽  
pp. 1438-1460 ◽  
Author(s):  
Vincent Anayochukwu Ani

Telecommunications industry requires efficient, reliable and cost-effective hybrid power system as alternative to the power supplied by diesel generator. This paper proposed an operational control algorithm that will be used to control and supervise the operations of PV/Wind-Diesel hybrid power generation system for GSM base station sites. The control algorithm was developed in such a way that it coordinates when power should be generated by renewable energy (PV panels and Wind turbine) and when it should be generated by diesel generator and is intended to maximize the use of renewable system while limiting the use of diesel generator. Diesel generator is allocated only when the demand cannot be met by the renewable energy sources including battery bank. The developed algorithm was used to study the operations of the hybrid PV/Wind-Diesel energy system. The control simulation shows that the developed algorithm reduces the operational hours of the diesel generator thereby reducing the running cost of the hybrid energy system as well as the pollutant emissions. With the data collected from the site, a detailed economic and environmental analysis was carried out using micro power optimization software homer. The study evaluates savings associated with conversion of the diesel powered system to a PV/Wind-Diesel hybrid power system.


Energies ◽  
2015 ◽  
Vol 8 (4) ◽  
pp. 2473-2492 ◽  
Author(s):  
Ying-Yi Hong ◽  
Yuan-Ming Lai ◽  
Yung-Ruei Chang ◽  
Yih-Der Lee ◽  
Pang-Wei Liu