Nusselt number and friction factor correlations for the solar air heater duct furnished with artificial cube shaped roughness elements on the absorber plate

Author(s):  
Madhukeshwara Nanjundappa
2018 ◽  
Vol 141 (3) ◽  
Author(s):  
Shantanu Purohit ◽  
N. Madhwesh ◽  
K. Vasudeva Karanth ◽  
N. Yagnesh Sharma

This study presents an innovative idea to augment heat transfer to an air heater using helicoidal finned arrangement. A parametric analysis of the helicoidal shaped fin geometry is considered with helicoidal pitch ratio of 0.1666–0.3, fin diameter ratio of 1.75–2. For the placement of the fin beneath the absorber plate, longitudinal pitch ratio ranging from 0.0416 to 0.1666 are used. The flow Reynolds number used for the study ranges from 4800 to 25,000. The effects of helicoidal pitch ratio, wire diameter ratio and longitudinal pitch ratio on Nusselt number and friction factor have been discussed. It is seen from the analysis that there is a significant improvement in Nusselt number for the case of helicoidal fin of wire diameter ratio of 1 when compared to base model as well as straight fin model for the operating range of Reynolds number. It is also observed from the analysis that for the helicoidal fin configuration of helicoidal pitch ratio of 0.2333, friction factor appears to be moderate. Flow and roughness parameters for roughened solar air heater have been optimized using thermal-hydraulic enhancement factor (THEF). The study reveals that by the use of helicoidal fins, maximum enhancement in the Nusselt number is found to be 2.21 times when compared to the base model for longitudinal pitch ratio of 0.0416, helicoidal pitch ratio of 0.166 for a fixed wire diameter. The improvement obtained in performance corresponding to increased Nusselt number establishes the efficacy the helicoidal fin design for the absorber plate.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Vipin B. Gawande ◽  
A. S. Dhoble ◽  
D. B. Zodpe

CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional vortex generator on the heat transfer and flow friction characteristics inside the solar air heater duct. This investigation covers relative roughness pitch in the range of 10 ≤P/e≤ 25 and relevant Reynolds numbers in the range of 3800 ≤ Re ≤ 18000. Relative roughness height (e/D) is kept constant as 0.03 for analysis. The turbulence created due to additional circular vortex generator increases the heat transfer rate and at the same time there is also increase in friction factor values. For combined arrangement of ribs and vortex generator, maximum Nusselt number is found to be 2.05 times that of the smooth duct. The enhancement in Nusselt number with ribs and additional vortex generator is found to be 1.06 times that of duct using ribs alone. The maximum increase in friction factor with ribs and circular vortex generator is found to be 2.91 times that of the smooth duct. Friction factor in a combined arrangement is 1.114 times that in a duct with ribs alone on the absorber plate. The augmentation in Thermal Enhancement Factor (TEF) with vortex generator in inlet section is found to be 1.06 times more than with circular ribs alone on the absorber plate.


Author(s):  
Sheetal Kumar Jain ◽  
Ghanshyam Das Agrawal ◽  
Rohit Misra

Abstract In the present research, the thermohydraulic performance of a solar air heater having artificial roughness in the form of arc-shaped ribs with multiple gaps has been investigated experimentally and compared with that of a solar air heater having smooth absorber plate. The performance has been investigated in terms of enhancement in the Nusselt number and friction factor. Results of the present work have also been compared with previously published work. Reynolds number and arc angle (α) were varied from 3000 to 18,000 and 30 deg to 75 deg, respectively. Present roughness results in a higher rate of heat transfer from the absorber surface to air, but it also imposes a penalty in terms of the increased friction factor. Maximum enhancement in Nusselt number, friction factor, and thermohydraulic performance parameter for the roughened absorber surface is found to be 3.74, 2.69, and 2.75 times that of the smooth plate, respectively. Correlations of heat transfer and friction factor for proposed roughness have also been developed.


Author(s):  
AVDHESH SHARMA ◽  
VARUN VARUN ◽  
GAURAV BHARADWAJ

Double pass solar air heater (DPSAH) consisted of rectangular duct provided with artificial roughness on both side of the absorber plate has been experimentally investigated. Circular ribs of aluminium wire is used to provide roughness to increase heat transfer coefficient between absorber plate and air. Ribs are attached to absorber plate at four different angle of attackbetween 30° to 75° . Experiment is carried out over the range of Reynolds Number from 4900 to 12000, and relative roughness height (e/Dh) varies from 0.022 to 0.044. Experimentally different values of Nusselt number(Nu). and friction factor(fr) have been determined for various parameters. The enhance-ment in heat transfer and increment in the friction factor values of Nusselt number and friction factor have also been compared with the smooth one.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Inzamam Ahmad ◽  
N. H. Khan ◽  
M. A. Hassan ◽  
M. K. Paswan

Abstract Thermal transport and flow friction characteristics due to roughness on the absorber plate of solar air heater are evaluated by applying three-dimensional finite volume based code. Renormalization group (RNG) k–ɛ model is employed to capture the turbulent nature of the flow. The effect of equilateral prism-shaped rib roughness geometrical parameters in terms of relative roughness height (e/D) and relative roughness pitch (p/e) on heat transfer and flow friction is analyzed. Further, the effect of flow parameter, Re in the range of 4000–18,000 is also explored. Results are elucidated in terms of average Nusselt number, friction factor, turbulent kinetic energy, and eddy dissipation. Results are compared with a smooth absorber plate solar air heater. Thermo-hydraulic performance of the roughened solar air heater is analyzed. Noteworthy augmentation in heat transport is obtained. The thermal enhancement factor is calculated for optimal performance and found to vary from 1.7 to 3.5. However, friction factor and pressure loss for roughened plate is significantly higher than its smooth counterpart. The pressure drop across the test section increases with the rise in roughness height due to flow obstruction. A minimum value of the friction factor enhancement ratio worth 2.13 is obtained. Enhancement in thermal transport and pressure losses are combined by introducing a thermo-hydraulic performance factor (THHP). For the range of parameters investigated, the optimum value of the thermo-hydraulic performance factor is found to be 3.41. Correlations for average Nusselt number and friction factor are offered at the end.


Sign in / Sign up

Export Citation Format

Share Document