Influence of Patient-Specific Characteristics on Transcatheter Heart Valve Neo-Sinus Flow: An In Silico Study

2020 ◽  
Vol 48 (10) ◽  
pp. 2400-2411
Author(s):  
Shelly Singh-Gryzbon ◽  
Beatrice Ncho ◽  
Vahid Sadri ◽  
Sanchita S. Bhat ◽  
Sai S. Kollapaneni ◽  
...  
2019 ◽  
Vol 48 (1) ◽  
pp. 169-180 ◽  
Author(s):  
Immanuel David Madukauwa-David ◽  
Vahid Sadri ◽  
Prem A Midha ◽  
Vasilis Babaliaros ◽  
Cyrus Aidun ◽  
...  

2019 ◽  
Vol 5 (1) ◽  
pp. 569-572
Author(s):  
Sylvia Pfensig ◽  
Daniela Arbeiter ◽  
Stefanie Kohse ◽  
Niels Grabow ◽  
Klaus-Peter Schmitz ◽  
...  

AbstractWhile the current generation of devices for minimally invasive treatment of severe symptomatic aortic valve stenosis is based on xenogenic leaflet-material, artificial polymeric leaflet-structures represent a promising approach for future improvement of heart valve performance. For enhanced long-term success of polymeric leafletstructures, limitations regarding calcification and durability have to be addressed. The objective of the presented study was the development of a constitutive law representing the material properties of artificial polymeric leaflet-structures of transcatheter heart valve prostheses in numerical simulation to assess the in silico leaflet-performance. Mechanical characterization of cast films and nonwoven specimens of a polycarbonate based silicone elastomer were conducted by means of uniaxial tension and planar shear testing, respectively. For validation purposes, experimental data were compared with the results of finite-element analysis (FEA) using different hyperelastic models. Strain energy function for third-order ogden hyperelastic model achieved the best fit of the non-linear stress-strain behavior of the isotropic polymeric material with the experimental data. It was chosen for further FEA of valve leaflet-performance under physiological pressurization to analyze the suitability of various manufacturing processes for polymeric leafletstructures. Therefore a specific leaflet-design with a wall thickness of 400 μm was used. As a result of FEA, time dependent leaflet-deformation, leaflet coaptation surface area (CSA) and leaflet opening area (LOA) of cast and nonwoven leaflet-structures were calculated. While LOA was comparable for cast and nonwoven leaflet-structures, obtained leaflet-dynamics in a cardiac cycle under physiological pressurization demonstrated crucial influence of the manufacturing process. For nonwoven leafletstructures, an enhanced CSA could be demonstrated in comparison to cast structures. FEA using a validated hyperelastic constitutive law represents a useful tool for in silico performance evaluation of polymeric leaflet-structures under physiological loading and proves the suitability of the polymeric artificial leaflet-material for percutaneous heart valve prostheses.


2019 ◽  
Vol 10 (3) ◽  
pp. 456-468
Author(s):  
Giorgia Rocatello ◽  
Gianluca De Santis ◽  
Sander De Bock ◽  
Matthieu De Beule ◽  
Patrick Segers ◽  
...  

Langmuir ◽  
2021 ◽  
Vol 37 (4) ◽  
pp. 1551-1562
Author(s):  
Ali Amani ◽  
Amir Shamloo ◽  
Saeid Barzegar ◽  
Mohamadamin Forouzandehmehr

Sign in / Sign up

Export Citation Format

Share Document