Experimental study on fire extinguishing with a newly prepared multi-component compressed air foam

2009 ◽  
Vol 54 (3) ◽  
pp. 492-496 ◽  
Author(s):  
XiShi Wang ◽  
YaoJian Liao ◽  
Lin Lin
2021 ◽  
Vol 234 ◽  
pp. 113949
Author(s):  
Yonghong Xu ◽  
Hongguang Zhang ◽  
Fubin Yang ◽  
Liang Tong ◽  
Yifan Yang ◽  
...  

2014 ◽  
Vol 41 (3) ◽  
pp. 188-192
Author(s):  
Vitor Mayer de Moura ◽  
Erinaldo Rocha Paes Lamdim ◽  
Felipe Souza Ferraz ◽  
Rodrigo Carvalho Turatti ◽  
Carolina de Barros Jaqueta ◽  
...  

OBJECTIVE: To experimentally compare two classic techniques described for manual suture of the bronchial stump. METHODS: We used organs of pigs, with isolated trachea and lungs, preserved by refrigeration. We dissected 30 bronchi, which were divided into three groups of ten bronchi each, of 3mm, 5mm, and 7mm, respectively. In each, we performed the suture with simple, separated, extramucosal stitches in five other bronchi, and the technique proposed by Ramirez and modified by Santos et al in the other five. Once the sutures were finished, the anastomoses were tested using compressed air ventilation, applying an endotracheal pressure of 20mmHg. RESULTS: the Ramirez Gama suture was more effective in the bronchi of 3, 5 and 7 mm, and there was no air leak even after subjecting them to a tracheal pressure of 20mmHg. The simple interrupted sutures were less effective, with extravasation in six of the 15 tested bronchi, especially in the angles of the sutures. These figures were not significant (p = 0.08). CONCLUSION: manual sutures of the bronchial stumps were more effective when the modified Ramirez Gama suture was used in the caliber bronchi arms when tested with increased endotracheal pressure.


2013 ◽  
Vol 790 ◽  
pp. 53-56
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Na

This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives.The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations,working pressures and nozzle different height above the fire source . The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.


Sign in / Sign up

Export Citation Format

Share Document