scholarly journals Hospital Readmissions After Surgical Treatment of Proximal Humerus Fractures: Is Arthroplasty Safer Than Open Reduction Internal Fixation?

2014 ◽  
Vol 472 (8) ◽  
pp. 2317-2324 ◽  
Author(s):  
Alan L. Zhang ◽  
William W. Schairer ◽  
Brian T. Feeley
Author(s):  
Sivakumar Arumugam ◽  
Venkateshwara Arumugam ◽  
V. Raviraman

<p class="abstract"><strong>Background:</strong> Proximal humerus fractures accounts for about 4 to 5% of all fractures.  Treatment of unstable, displaced, and comminuted fractures of the proximal humerus remain challenging. Significant controversy continues regarding the best methods of treating displaced proximal humerus fractures. Various operative procedures are carried out, the recent trend in internal fixation has moved on to locking plates. The present study is undertaken to evaluate the functional outcome and complication of proximal humerus fractures treated by locking compression plate.</p><p class="abstract"><strong>Methods:</strong> This is a prospective study comprising of 30 patients with fractures of proximal humerus were treated by open reduction and internal fixation with locking compression plate were evaluated at Velammal  Institute Of Medical  Sciences, Madurai from the period of April 2015 to December 2016. Clinical and radiological evaluation was done. Patients will undergo open reduction internal fixation with locking compression plate for the sustained fracture under general anesthesia.<strong></strong></p><p class="abstract"><strong>Results:</strong> In our series, the majority of the patients were males, elderly aged, with RTA being the commonest mode of injury, involving 2 part, 3 part and 4 part fractures of the proximal humerus. Excellent and satisfactory results were found in 76.7% of patients with unsatisfactory results in 23.3 % according to Neer’s criteria. There were 100 % union rates and no failures.</p><p><strong>Conclusions:</strong> In conclusion locking Compression, the plate is an advantageous implant in proximal humeral fractures due to angular stability, particularly in comminuted fractures and in Osteoporotic bones in elderly patients, thus allowing early mobilization.</p>


2021 ◽  
Vol 10 (4) ◽  
pp. 3266-3269
Author(s):  
Abhishek Patil

Proximal humerus fractures account for about 4% to 5% of all fractures. Following distal forearm fracture, proximal humeral fracture is the second most common upper extremity fracture. Kirschner (K)-Wires, external fixation, tension band wiring, and rush pins, intramedullary nails, ORIF with plates, and shoulder hemiarthroplasty have all been offered as therapeutic options. The purpose of this study was to assess the functional outcome and complication rates following internal fixation of proximal humerus fractures using a locking compression plate. Patients over the age of 18 with closed proximal humerus fractures or open proximal humerus fractures (Gustilo and Anderson type I, Type II) received open reduction and internal fixation with locking compression plate in the current study. The participants in this study were 60 people who had a proximal humerus fracture and were treated with open reduction and a proximal humerus locking compression plate. Patients ranged in age from 20 to 85 years old, with a mean age of 51.14 +/- 17.30 years. The age group 36–55 years (37 percent) was the most prevalent, followed by 56–75 years (30 %). The majority of patients (76.7 %) were men who had been in automobile accidents on the right side (83 %) (63 %). According to the Neer classification, the most prevalent type of fracture was a three-part fracture (53 %). The maximum union time observed in this study was 16 weeks, with a minimum of 10 weeks. The average time to union is 12.52 +/- 1.14 weeks. The mean flexion at the end of six months was 121.660 +/- 19.84. The mean internal rotation was 57.330 +/- 8.48, the mean external rotation was 530 +/- 11.98, and the mean abduction was 1180 +/- 19.36. 75.28 +/- 9.66 [Mean +/- SD] is the Mean Constant score. Pain 14.10, ADL 18.26, range of motion 22.46, and power 20 were the mean scores observed on Constant Score for its various aspects. According to the Constant score, the functional outcome of the 60 patients was as follows: 8 patients had excellent outcomes (13%), 34 patients had good outcomes (56.7%), 16 patients had moderate outcomes (26.7%), and two patients had poor outcomes (26.7%) and (3 %). Internal fixation of proximal humerus fractures with a locking compression plate results in anatomical reduction and secure fixation, resulting in a favorable functional outcome.


Sign in / Sign up

Export Citation Format

Share Document