Accurate 3D reconstruction of subject-specific knee finite element model to simulate the articular cartilage defects

2011 ◽  
Vol 16 (5) ◽  
pp. 620-627 ◽  
Author(s):  
Yue-fu Dong ◽  
Guang-hong Hu ◽  
Luo-lian Zhang ◽  
Yang Hu ◽  
Ying-hai Dong ◽  
...  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xiaohui Zhang ◽  
Shuo Yuan ◽  
Jun Wang ◽  
Bagen Liao ◽  
De Liang

Abstract Background Recent studies have pointed out that arthroscopy, the commonly-used surgical procedure for meniscal tears, may lead to an elevated risk of knee osteoarthritis (KOA). The biomechanical factors of KOA can be clarified by the biomechanical analysis after arthroscopic partial meniscectomy (APM). This study aimed to elucidate the cartilage stress and meniscus displacement of the tibiofemoral joint under flexion and rotation loads after APM. Methods A detailed finite element model of the knee bone, cartilage, meniscus, and major ligaments was established by combining computed tomography and magnetic resonance images. Vertical load and front load were applied to simulate different knee buckling angles. At the same time, by simulating flexion of different degrees and internal and external rotations, the stresses on tibiofemoral articular cartilage and meniscus displacement were evaluated. Results Generally, the contact stress on both the femoral tibial articular cartilage and the meniscus increased with the increased flexion degree. Moreover, the maximum stress on the tibial plateau gradually moved backward. The maximum position shift value of the lateral meniscus was larger than that of the medial meniscus. Conclusion Our finite element model provides a realistic three-dimensional model to evaluate the influence of different joint range of motion and rotating tibiofemoral joint stress distribution. The decreased displacement of the medial meniscus may explain the higher pressure on the knee components. These characteristics of the medial tibiofemoral joint indicate the potential biomechanical risk of knee degeneration.


2012 ◽  
Vol 45 ◽  
pp. S526
Author(s):  
R. Allena ◽  
L. Duchemin ◽  
V. Bousson ◽  
D. Mitton ◽  
J.D. Laredo ◽  
...  

Author(s):  
Emiliano P Ravera ◽  
Marcos J Crespo ◽  
Paola A Catalfamo Formento

Analysis of the human locomotor system using rigid-body musculoskeletal models has increased in the biomechanical community with the objective of studying muscle activations of different movements. Simultaneously, the finite element method has emerged as a complementary approach for analyzing the mechanical behavior of tissues. This study presents an integrative biomechanical framework for gait analysis by linking a musculoskeletal model and a subject-specific finite element model of the pelvis. To investigate its performance, a convergence study was performed and its sensitivity to the use of non-subject-specific material properties was studied. The total hip joint force estimated by the rigid musculoskeletal model and by the finite element model showed good agreement, suggesting that the integrative approach estimates adequately (in shape and magnitude) the hip total contact force. Previous studies found movements of up to 1.4 mm in the anterior–posterior direction, for single leg stance. These results are comparable with the displacement values found in this study: 0–0.5 mm in the sagittal axis. Maximum von Mises stress values of approximately 17 MPa were found in the pelvic bone. Comparing this results with a previous study of our group, the new findings show that the introduction of muscular boundary conditions and the flexion–extension movement of the hip reduce the regions of high stress and distributes more uniformly the stress across the pelvic bone. Thus, it is thought that muscle force has a relevant impact in reducing stresses in pelvic bone during walking of the finite element model proposed in this study. Future work will focus on including other deformable structures, such as the femur and the tibia, and subject-specific material properties.


2018 ◽  
Vol 18 (02) ◽  
pp. 1850020 ◽  
Author(s):  
TIEN TUAN DAO ◽  
ANG-XIAO FAN ◽  
STÉPHANIE DAKPÉ ◽  
PHILIPPE POULETAUT ◽  
MOHAMED RACHIK ◽  
...  

Facial muscle coordination is a fundamental mechanism for facial mimics and expressions. The understanding of this complex mechanism leads to better diagnosis and treatment of facial disorders like facial palsy or disfigurement. The objective of this work was to use magnetic resonance imaging (MRI) technique to characterize the activation behavior of facial muscles and then simulate their coordination mechanism using a subject specific finite element model. MRI data of lower head of a healthy subject were acquired in neutral and in the pronunciation of the sound [o] positions. Then, a finite element model was derived directly from acquired MRI images in neutral position. Transversely-isotropic, hyperelastic, quasi-incompressible behavior law was implemented for modeling facial muscles. The simulation to produce the pronunciation of the sound [o] was performed by the cumulative coordination between three pairs of facial mimic muscles (Zygomaticus Major (ZM), Levator Labii Superioris (LLS), Levator Anguli Oris (LAO)). Mean displacement amplitude showed a good agreement with a relative deviation of 15% between numerical outcome and MRI-based measurement when all three muscles are involved. This study elucidates, for the first time, the facial muscle coordination using in vivo data leading to improve the model understanding and simulation outcomes.


2014 ◽  
Vol 47 (1) ◽  
pp. 65-73 ◽  
Author(s):  
Simon M. Harrison ◽  
R. Chris Whitton ◽  
Chris E. Kawcak ◽  
Susan M. Stover ◽  
Marcus G. Pandy

Sign in / Sign up

Export Citation Format

Share Document