Successful total repair of interrupted aortic arch associated with ventricular septal defect and large patent ductus arteriosus

1974 ◽  
Vol 33 (4) ◽  
pp. 566-571 ◽  
Author(s):  
Jacques G. Losman ◽  
Hymie S. Joffe ◽  
Walter Beck ◽  
Christiaan Barnard
2021 ◽  
Vol 14 (7) ◽  
pp. e239654
Author(s):  
Parveen Kumar ◽  
Mona Bhatia ◽  
Khemendra Kumar ◽  
Shashank Jain

Isolation of the left subclavian artery or its anomalous origin from the pulmonary artery has been documented in several cases, especially in association with a right-sided aortic arch. However, similar anomaly involving the right subclavian artery has been less frequently reported. Isolated right subclavian artery in association with interrupted aortic arch (IAA) is extremely rare, and only three cases have been reported so far. Here, we have presented yet another case of isolated right subclavian artery associated with ventricular septal defect, type B IAA and bilateral patent ductus arteriosus.


1977 ◽  
Vol 74 (6) ◽  
pp. 913-917 ◽  
Author(s):  
Kenji Ito ◽  
Naoaki Kohguchi ◽  
Yasunori Ohkawa ◽  
Tadayoshi Akasaka ◽  
Hiroshi Ohara ◽  
...  

1982 ◽  
Vol 46 (7) ◽  
pp. 701-705
Author(s):  
KUNlO SATO ◽  
TSUNEYUKI WATANABE ◽  
HIROSHI KANDA ◽  
TADASHI SUZUKI ◽  
YOSHIHARU ISHIZAWA ◽  
...  

2021 ◽  
pp. 1-4
Author(s):  
Zahra Khajali ◽  
Ata Firouzi ◽  
Homa Ghaderian ◽  
Maryam Aliramezany

Abstract Ductus arteriosus is a physiological structure if not closed after birth, may lead to many complications. Today, trans-catheter closure of patent ductus arteriosus with Occluder devices is the preferred method. Surgical ligation is used only in certain cases such as large symptomatic patent ductus arteriosus in very small infants and premature babies; unfavourable structure of the duct or economic considerations. In this article, we described haemodynamic and morphological characteristics of five patients with large patent ductus arteriosus which were occluded with Amplatzer device. From 23 January, 2010 to 31 July, 2018, five patients referred to our clinic with large patent ductus arteriosus and pulmonary arterial hypertension for further evaluation. After assessing them with various diagnostic methods, we decided to close defect with ventricular septal defect Occluder device. Patients aged 21–44 years and one of them was male. Ductus closure was successfully done with ventricular septal defect Occluder device. Closure was successful for all of them but in one case, whose device was embolized to pulmonary artery after 24 hr and he underwent surgery. Trans-catheter closure of large patent ductus arteriosus in adult patients with pulmonary hypertension is feasible. Despite the fact that complications may occur even with the most experienced hands, the ‘double disk’ Amplatzer ventricular septal defect muscular Occluder could be advantageous in this setting.


Sign in / Sign up

Export Citation Format

Share Document