Convective heat transfer on a plate in an impinging round hot gas jet of low Reynolds number

1980 ◽  
Vol 23 (8) ◽  
pp. 1055-1068 ◽  
Author(s):  
Cz.O. Popiel ◽  
Th.H. van der Meer ◽  
C.J. Hoogendoorn
1999 ◽  
Vol 121 (3) ◽  
pp. 712-719 ◽  
Author(s):  
M. Rokni ◽  
B. Sunden

This investigation concerns numerical calculation of turbulent forced convective heat transfer and fluid flow in their fully developed state at low Reynolds number. The authors have developed a low Reynolds number version of the nonlinear k-ε model combined with the heat flux models of simple eddy diffusivity (SED), low Reynolds number version of generalized gradient diffusion hypothesis (GGDH), and wealth ∝ earning × time (WET) in general three-dimensional geometries. The numerical approach is based on the finite volume technique with a nonstaggered grid arrangement and the SIMPLEC algorithm. Results have been obtained with the nonlinear k-ε model, combined with the Lam-Bremhorst and the Abe-Kondoh-Nagano damping functions for low Reynolds numbers.


Author(s):  
Sivaraja Subramania Pillai ◽  
Ryuichiro Yoshie

This study focuses on the Convective Heat Transfer Coefficient (CHTC) from urban building surfaces by numerical simulation. The heat transfer effects because of various geometrical and physical properties of urban areas exhibits a differential heating and uncomfortable environment compared to rural regions called as Urban Heat Island (UHI) phenomena. Investigation of Convective heat transfer coefficient becomes more important in the study of urban heat island phenomena. Experimental simulation of urban area with various urban canopy cases in thermally stratified wind tunnel is employed for the heat transfer kind of investigations in urban area. But, it is not an easy task in wind tunnel experiments to evaluate local CHTC, which vary on individual canyon surfaces transfer such as building roof, walls and ground. Numerical simulation validated by wind tunnel experiments can be an alternative for the prediction of CHTC from building surfaces in an urban area. In our study, Water evaporation technique used in wind tunnel experiment for the evaluation of convective heat transfer coefficient and naphthalene sublimation technique conducted by other researchers are used to validate the low-Reynolds-number k-ε model which was used for the evaluation of CHTC from surfaces. The calculated CFD results showed good agreement with both water evaporation technique and naphthalene sublimation experimental results. It is found that the low-Reynolds-number k-ε model is reliable for the investigations pertaining to heat transfer from urban canopy.


Sign in / Sign up

Export Citation Format

Share Document