Comparison of isotachophoresis, capillary zone electrophoresis and high-performance liquid chromatography for the determination of salbutamol, terbutaline sulphate and fenoterol hydrobromide in pharmaceutical dosage forms

1992 ◽  
Vol 590 (2) ◽  
pp. 341-353 ◽  
Author(s):  
M.T. Ackermans ◽  
J.L. Beckers ◽  
F.M. Everaerts ◽  
I.G.J.A. Seelen
2011 ◽  
Vol 17 (1) ◽  
pp. 25-31 ◽  
Author(s):  
Bilal Yilmaz ◽  
Kadem Meral ◽  
Ali Asci ◽  
Yavuz Organer

In this study, a new and rapid spectrofluorometry and high performance liquid chromatography (HPLC) methods were developed for determination of metoprolol in pure and pharmaceutical dosage forms. The solvent system, wavelength of detection and chromatographic conditions were optimized in order to maximize the sensitivity of both the proposed methods. The linearity was established over the concentration range of 50-4000 ng ml-1 for spectrofluorometry and 5.0-300 ng ml-1 for HPLC methods. The intra- and inter-day relative standard deviation (RSD) was less than 4.14 and 3.86% for spectrofluorometry and HPLC, respectively. Limit of quantitation was determined as 30 and 5.0 ng ml-1 for spectrofluorometry and HPLC, respectively. No interference was found from tablet excipients at the selected assay conditions. The methods were applied for the quality control of commercial metoprolol dosage forms to quantify the drug and to check the formulation content uniformity.


2016 ◽  
Vol 66 (1) ◽  
pp. 109-118 ◽  
Author(s):  
Soad S. Abd El-Hay ◽  
Hisham Hashem ◽  
Ayman A. Gouda

Abstract A novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less than two minutes. The separation was performed on a RP C-18 stationary phase with an isocratic elution system consisting of 0.03 mol L−1 orthophosphoric acid (pH 2.3) and acetonitrile (ACN) as the mobile phase in the ratio of 50:50, at 2.0 mL min−1 flow rate at room temperature. Detection was performed at 220 nm. Validation was performed concerning system suitability, limits of detection and quantitation, accuracy, precision, linearity and robustness. Calibration curves were rectilinear over the range of 0.195–100 μg mL−1 for all the drugs studied. Recovery values were 99.9, 99.6 and 99.0 % for XIP, TRI and HCT, respectively. The method was applied to simultaneous determination of the studied analytes in their pharmaceutical dosage forms.


Sign in / Sign up

Export Citation Format

Share Document