Room air circulation — The missing link to good indoor air quality

1996 ◽  
Vol 37 (3) ◽  
pp. 215
Author(s):  
R. Kelley
Author(s):  
Dyah Nurwidyaningrum ◽  
Miftahul Ulum ◽  
Billy Septanto Syamsumarno

The most significant energy used in middle-class apartments is the air circulation unit. The use of energy from the air circulation system is related to the comfort of the user in the housing unit, so it adjusts to the applicable standard. The objection of this study is to investigate the optimization of the air circulation system in middle-class apartments in an urban area. The method is a comparative study of the government standard. The stages of the research did site observation, take air quality measurement, and interview with the questionnaire. Indoor air quality data collected are temperature, relative humidity, CO, and CO2. The data measurement compared to SNI 03-6572-2001 on Procedures for Designing Air Conditioning and Ventilation Systems in Buildings, Indonesian National Standardization.  The questionnaire was to find out the comfort of residents on indoor air quality (IAQ). This study reveals that almost all air quality aspects are consistent to standard, except the temperature. The results of this study that meet the criteria related to air circulation are air movement 40%, relative humidity 65.5%, air movement 40%, CO 78%, and CO2 95%. The result of the questionnaires states that 72.4% of residents feel comfortable with the air quality in the dwelling unit. The size of the room and the adequacy of ventilation in the place influences the value of the air circulation system besides air movement.


2006 ◽  
Vol 510-511 ◽  
pp. 934-937 ◽  
Author(s):  
Hyung Mi Lim ◽  
Ji Sook Jung ◽  
Dae Sung Kim ◽  
Dong Jin Lee ◽  
Seung Ho Lee ◽  
...  

The application of VOC-free materials for building interior is the first step to reduce the contamination level, however, it is practically unavoidable to find a way to eliminate existing pollutants from furniture, adhesives, etc. As a positive way of controlling the air indooors, the air conditioner may be applied with high functional filter, which uses electricity for compulsory air circulation. As an alternative, we modified natural zeolite powder by ion exchange and also by addition of TiO2 photo-catalyst for multifunctional powder to contribute to controlling the indoor air quality. The modified zeolites were applied on the interior non-woven polypropylene sheet to reduce indoor air pollutants not only by adsorption mechanism but also by decomposition mechanism. We studied deodorization of the multi-functional powders and also their coating on non-woven textiles by a Gastec method.


2017 ◽  
Vol 22 (07/08) ◽  
pp. 106-107
Author(s):  
Marc Lichtenthäler

Viele Studien belegen, dass durch eine hohe Indoor Air Quality die Produktivität gesteigert, Fehlzeiten abgebaut und Herz-Kreislauf-Erkrankungen vermieden werden können. Neben Behandlungs-, OP- und Pflegebereichen eines Klinikums sollten deshalb auch Bereiche mit gut aufbereiteter Raumluft bedacht werden, in denen sich ausschließlich Mitarbeiter aufhalten.