Design of pulsed-neutron reservoir monitoring programs

1992 ◽  
Vol 7 (01) ◽  
pp. 93-98 ◽  
Author(s):  
S.J. Kimminau ◽  
R.E. Plasek

2021 ◽  
Author(s):  
Mohamed Elyas ◽  
Sherif Aly ◽  
Uche Achinanya ◽  
Sergey Prosvirkin ◽  
Shayma AlSaffar ◽  
...  

Abstract Well integrity is one of the main challenges that are facing operators, finding the source of the well problem and isolating it before a catastrophic event occurs. This study demonstrates the power of integrating different reservoir monitoring and well integrity logs to evaluate well integrity, identify the underlying cause of the potential failure, and providing a potential corrective solution. Recently, some Injector/producer wells reported migration of injection fluids/gas into shallower sections, charging these formations and increasing the risk of compromised well integrity. Characterization of the well issues required integration of multi-detector pulsed-neutron, well integrity (multi finger caliper, multi-barrier corrosion, cement evaluation, and casing thickness measurements), high precision temperature logs and spectral noise logs. After data integration, detailed analysis was performed to specifically find the unique issues in each well and assess possible corrective actions. The integrated well integrity logs clearly showed different 9.625-inch and 13.375-inch casings leak points. The reservoir monitoring logs showed lateral and vertical gas and water movements across Wara, Tayarat, Rus, and Radhuma formations. Cement evaluation loges showed no primary cement behind the first barrier casing which was the root cause of the problem. Therefore, the proposed solution, was a cement squeeze. Post squeeze, re-logging occurred, validating zonal isolation and a return of a standard geothermal gradient across the Tayarat formation. Most importantly, the cement evaluation identified good bond from the squeeze point clear to surface, isolating all formations. All these wells were returned to service (injector/producer), daily annular pressure monitoring confirmed that no further pressure build up was seen. Kuwait Oil Company managed to avoid a catastrophic well integrity event on these wells and utilized the approach presented to take the proper corrective actions, and validate that the action taken resolved the initial well integrity issues. Consequently, the wells were returned to service, and the company avoided a costly high probability blowout.


2005 ◽  
Author(s):  
Charles W. Morris ◽  
Frank Morris ◽  
Timothy Michael Quinlan ◽  
Taha A. Aswad

2005 ◽  
Author(s):  
C. Morris ◽  
T. Aswad ◽  
F. Morris ◽  
T. Quinlan

Author(s):  
T. Egami ◽  
H. D. Rosenfeld ◽  
S. Teslic

Relaxor ferroelectrics, such as Pb(Mg1/3Nb2/3)O3 (PMN) or (Pb·88La ·12)(Zr·65Ti·35)O3 (PLZT), show diffuse ferroelectric transition which depends upon frequency of the a.c. field. In spite of their wide use in various applications details of their atomic structure and the mechanism of relaxor ferroelectric transition are not sufficiently understood. While their crystallographic structure is cubic perovskite, ABO3, their thermal factors (apparent amplitude of thermal vibration) is quite large, suggesting local displacive disorder due to heterovalent ion mixing. Electron microscopy suggests nano-scale structural as well as chemical inhomogeneity.We have studied the atomic structure of these solids by pulsed neutron scattering using the atomic pair-distribution analysis. The measurements were made at the Intense Pulsed Neutron Source (IPNS) of Argonne National Laboratory. Pulsed neutrons are produced by a pulsed proton beam accelerated to 750 MeV hitting a uranium target at a rate of 30 Hz. Even after moderation by a liquid methane moderator high flux of epithermal neutrons with energies ranging up to few eV’s remain.


Sign in / Sign up

Export Citation Format

Share Document