Hydrophilic and hydrophobic materials as internal insulations for historic masonry walls

2022 ◽  
pp. 39-51
Author(s):  
Thomas Stahl ◽  
Karim Ghazi Wakili
2021 ◽  
Vol 228 ◽  
pp. 111507
Author(s):  
Xianhua Yao ◽  
Zi-Xiong Guo ◽  
Syed Humayun Basha ◽  
Qunxian Huang

2014 ◽  
Vol 624 ◽  
pp. 354-362
Author(s):  
Jerzy Jasienko ◽  
Łukasz Bednarz ◽  
Dariusz Bajno

The paper presents a structural analysis, restoration programme and scope of conservation work essential for protecting historical values based on the example of an overstretched retaining wall providing support for the embankment of an heritage church. The focus was on analysing the status of an historic stone wall constructed in part with bog iron ore (metal ore or iron-rich sedimentary rock). Ore was used for iron smelting and also as a building material. Bog iron ore was frequently used in construction across Poland, especially in places where the raw material was locally available, aesthetically attractive and had mechanical properties approximating the durability of ceramic bricks. The material was characterised by high porosity, low resistance to diffusion and high resistance to freezing, which meant that it could be used successfully in structures subjected to atmospheric impacts without additional protection


Author(s):  
Panagiotis G. Asteris ◽  
Vasilis Sarhosis ◽  
Amin Mohebkhah ◽  
Vagelis Plevris ◽  
L. Papaloizou ◽  
...  

The majority of historical and heritage structures around the world consist of unreinforced masonry walls. A masonry structure is composed of masonry units, such as brick or marble blocks, with or without a joint filling material, such as mortar. A masonry with a joint material is usually made of two different materials (i.e. masonry units and mortar), representing a non-homogeneous and anisotropic structural component. In other words, masonry is a discontinuous structural component whose deformations and failure mechanism are governed by its blocky behavior. Some ancient masonry structures, such as ancient columns and colonnades, are constructed without any form of joint material between the individual blocks. Therefore, the isotropic elastic continuum-based models are not suitable for the simulation of the real nonlinear behavior of masonry walls under applied load.


Heritage ◽  
2020 ◽  
Vol 3 (4) ◽  
pp. 1162-1198
Author(s):  
Antonio Borri ◽  
Marco Corradi ◽  
Alessandro De Maria

The visual method for assessment of the structural behaviour of historic masonry walls, known by the acronym MQI (Masonry Quality Index) was introduced in 2002 by a team of researchers from the University of Perugia, Italy. This is based on a visual survey of the faces and the cross section of a wall panel, and it aims at verifying if a wall complies with the “rules of the art”. Based on this analysis, it is possible to calculate a numerical index: numerous tests, carried out on site by the authors to validate the method, have demonstrated that the index is able to provide useful information about the mechanical characteristics and structural response, in general, of the analysed wall panel. The failure mode of a wall panel under the action of an earthquake is a critical aspect. In general, the failure modes can be categorized in two classes: masonry disaggregation and the development of a local or global mechanism of wall elements (macroelements). Several theoretical models and numerical simulations only consider the latter. In this paper, application of the MQI method is further investigated, with particular emphasis to those masonry typologies which are more prone to collapse by disaggregation during a seismic event. Under the action of an earthquake, some types of masonry are typically unable to deform and to split in macroelements, and another type of failure occurs: this is the so-called “masonry disaggregation” or “masonry crumbling”. This type of failure anticipates the ones resulting from macroelement methods or stress analysis. As a conclusion, these latter methods become completely inappropriate and potentially hazardous, as they overestimate the seismic capacity of the building under investigation. The MQI method has been adapted to assess the structural response of different types of masonry under the action of an earthquake. In detail, the aim was to verify when the phenomenon of masonry disaggregation is likely to occur.


Author(s):  
Marco Corradi ◽  
Adelaja Israel Osofero ◽  
Antonio Borri ◽  
Giulio Castori

Existing un-reinforced masonry buildings made of vaults, columns and brick and multi-leaf stone masonry walls, many of which have historical and cultural importance, constitute a significant portion of construction heritage in Europe and rest of the world. Recent earthquakes in southern Europe have shown the vulnerability of un-reinforced masonry constructions due to masonry almost total lack of tensile resistance. Composite materials offer promising retrofitting possibilities for masonry buildings and present several well-known advantages over existing conventional techniques. The aim of this work is to analyze the effectiveness of seismic-upgrading methods both on un-damaged (preventive reinforcement) and damaged (repair) masonry building. After a brief description of mechanical and physical properties of composite materials, three different applications have been addressed: in-plane reinforcement of masonry walls, extrados and intrados reinforcement of masonry vaults/arches and masonry column confinement with composite materials.


2021 ◽  
Vol 898 ◽  
pp. 1-7
Author(s):  
Ingrid Boem ◽  
Natalino Gattesco

Historic masonry buildings experience a high seismic vulnerability: innovative intervention strategies for strengthening, based on the use of fibre-based composite materials are gradually spreading. In particular, the coupling of fibre-based materials with mortar layers (Fibre Reinforced Mortar technique - FRM) evidenced a good chemical and mechanical compatibility with the historical masonry and proved to be effective for the enhancement of both in-plane and out-of-plane performances of masonry, contrasting the opening of cracks and improving both resistance and ductility. The resistant mechanisms that arise in FRM strengthened masonry walls subjected to in-plane horizontal actions are analyzed in the paper and a practical design approach to evaluate their performances is illustrated, evidencing the dominant collapse mode at the varying of the masonry characteristics. Some masonry walls are analyzed numerically and analytically, as “case study”.


Author(s):  
Panagiotis G. Asteris ◽  
Vasilis Sarhosis ◽  
Amin Mohebkhah ◽  
Vagelis Plevris ◽  
L. Papaloizou ◽  
...  

The majority of historical and heritage structures around the world consist of unreinforced masonry walls. A masonry structure is composed of masonry units, such as brick or marble blocks, with or without a joint filling material, such as mortar. A masonry with a joint material is usually made of two different materials (i.e. masonry units and mortar), representing a non-homogeneous and anisotropic structural component. In other words, masonry is a discontinuous structural component whose deformations and failure mechanism are governed by its blocky behavior. Some ancient masonry structures, such as ancient columns and colonnades, are constructed without any form of joint material between the individual blocks. Therefore, the isotropic elastic continuum-based models are not suitable for the simulation of the real nonlinear behavior of masonry walls under applied load.


Sign in / Sign up

Export Citation Format

Share Document