Refractive Laser-Assisted Cataract Surgery versus Conventional Manual Surgery: Comparing Efficacy and Safety in 3144 Eyes

2019 ◽  
Vol 206 ◽  
pp. 32-39 ◽  
Author(s):  
Harrish Nithianandan ◽  
Vibeeshan Jegatheeswaran ◽  
Vishruti Dalal ◽  
Steve A. Arshinoff ◽  
Raj Maini ◽  
...  
2013 ◽  
Vol 90 (2) ◽  
pp. 185-190 ◽  
Author(s):  
Isabel Signes-Soler ◽  
Jaime Javaloy ◽  
Robert Montés-Micó ◽  
Gonzalo Muñoz ◽  
César Albarrán-Diego

2012 ◽  
Vol 06 (04) ◽  
pp. 218
Author(s):  
Giovanni Taibbi ◽  
Gianmarco Vizzeri ◽  
◽  

Cataract and glaucoma are the two leading causes of blindness worldwide and frequently co-exist in the ageing population. No uniform recommendations can be proposed when the two conditions are associated. In the presence of a visually significant cataract and uncontrolled glaucoma, clinicians should consider performing combined cataract surgery and trabeculectomy. Numerous phacotrabeculectomy techniques have been proposed. However, in the absence of strong evidence in support of a specific technique, surgeons’ preference and experience may dictate the choice. Unless contraindicated, mitomycin-C should be considered in all combined procedures. In addition, novel and minimally invasive glaucoma surgical procedures, such as ab interno trabeculotomy, have recently emerged and gained in popularity. In general, these procedures have shown the potential to be combined with phacoemulsification to further lower intraocular pressure (IOP) with relatively few post-operative complications. However, available data suggest that these techniques seem unlikely to be able to achieve a degree of IOP reduction comparable with that of trabeculectomy. Rigorous studies are necessary to better understand the long-term efficacy and safety profile of these novel procedures, when performed alone or in combination with cataract surgery.


Eye ◽  
2005 ◽  
Vol 21 (1) ◽  
pp. 58-64 ◽  
Author(s):  
S Russo ◽  
V Papa ◽  
A Di Bella ◽  
A Favero ◽  
C Radulescu ◽  
...  

Ophthalmology ◽  
2016 ◽  
Vol 123 (10) ◽  
pp. 2113-2126 ◽  
Author(s):  
Marko Popovic ◽  
Xavier Campos-Möller ◽  
Matthew B. Schlenker ◽  
Iqbal Ike K. Ahmed

2021 ◽  
Vol 10 (10) ◽  
pp. 2129
Author(s):  
Yuji Takayanagi ◽  
Sho Ichioka ◽  
Akiko Ishida ◽  
Aika Tsutsui ◽  
Masaki Tanito

The aim of this study is to compare the surgical efficacy and safety between microhook ab-interno trabeculotomy (µLOT) and iStent trabecular micro-bypass stent implantation when both were combined with cataract surgery in both eyes of patients. Sixty-four glaucomatous eyes (32 participants; mean age, 75.9 ± 7.6 years; 15 men, 17 women) were included retrospectively. Intraocular pressure (IOP), number of antiglaucoma medications, best-corrected visual acuity (BCVA), anterior chamber flare (ACF) and corneal endothelial cell density (CECD) were evaluated preoperatively, as well as 2, 3, 6, and 12 months postoperatively. Surgical complications and interventions were compared between the procedures. The preoperative IOP and medications with µLOT (18.8 ± 5.7 mmHg and 3.0 ± 1.2, respectively) were higher than with the iStent (15.5 ± 3.4 mmHg and 2.7 ± 1.2, respectively) (p = 0.0001 and p = 0.0437, respectively). At 12 months, the µLOT values (12.6 ± 2.3 mmHg and 2.3 ± 0.9, respectively) were identical to iStent (12.8 ± 2.5 mmHg and 2.3 ± 0.9, respectively) (p = 0.0934 and p = 0.3251, respectively). At 12 months, the IOP decreased more with µLOT (6.2 mmHg, 29.5%) than iStent (2.7 mmHg, 15.6%) (p = 0.0003). The decrease in medications was greater with µLOT (0.7) than iStent (0.4) (p = 0.0437). Survival rate of IOP control ≤15 mmHg and IOP reduction ≥20% was significantly higher after µLOT (40.6% at 12 months) than iStent (18.8%) (p = 0.0277). The frequency of layered hyphema was significantly greater with µLOT (8 eyes, 25%) than iStent (0 eyes, 0%) (p = 0.0048). The increase in the ACF at 2 weeks postoperatively was significantly greater with µLOT than iStent (p = 0.0156), while changes in the BCVA and CECD were identical between groups. The fellow-eye comparison showed that the IOP reduction was greater with µLOT than iStent when combined with cataract surgery.


Sign in / Sign up

Export Citation Format

Share Document