corneal endothelial cell density
Recently Published Documents


TOTAL DOCUMENTS

208
(FIVE YEARS 86)

H-INDEX

22
(FIVE YEARS 3)

2022 ◽  
Author(s):  
Mitsuya Otsuka ◽  
Atsushi Hayashi ◽  
Naoki Tojo

Abstract Purpose: To compare surgical outcomes between Ex-PRESS® surgery (EXP) and trabeculectomy (Trab) for primary open angle glaucoma (POAG) with low preoperative intraocular pressure (IOP).Patients and Methods: This was a retrospective non-randomized study. We included POAG patients with preoperative IOP ≤16 mmHg who were taking tolerance glaucoma medications. We compared the surgical outcomes, postoperative IOP, number of glaucoma medications, reduction rate of corneal endothelial cell density (ECD), visual acuity, and postoperative complications between POAG patients who underwent EXP (34 eyes) or Trab (38 eyes) and could be followed for >2 years.Results: Both surgeries significantly decreased the IOP (p<0.001): at 2 years, EXP provided decreases from 13.4 ± 2.3 to 10.2 ± 3.1 mmHg, Trab provided decreases from 13.5 ± 2.0 to 8.9 ± 3.2 mmHg. No significant differences were observed in the postoperative IOP (p=0.076), number of postoperative medications (p=0.263), success rate (p=0.900), reduction rate of ECD (p=0.410), or difference in visual acuity (p=0.174). The reduction rate of IOP was significantly high in the Trab group (p=0.047).Conclusions: Both surgeries significantly decreased IOP and were useful surgical methods for low-IOP glaucoma. Our results suggest that trabeculectomy can decrease IOP more than Ex-PRESS surgery but might have more complications.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Nian Guan ◽  
Xiao-Nong Zhang ◽  
Wan-Jun Zhang

Abstract Background Implantable Collamer lens (ICL) vaulting is one of the most important parameters for the safety, aqueous humor circulation, and lens transparency after ICL implantation. This study aimed to investigate the factors associated with the actual vaulting after refractive EVO-ICL surgery. Methods This retrospective study included patients who underwent EVO-ICL surgery at a tertiary eye hospital between October and December 2019. A RESCAN 700 was used for the intraoperative and CIRRUS HD-OCT was used for postoperative observation of vaulting. Subjective and objective refractions, anterior ocular segment, corneal morphology, intraocular pressure (IOP), anterior chamber volume (ACV), crystalline lens rise (CLR), white-to-white distance (WTW), anterior chamber depth (ACD), axial length, corneal endothelial cell density (ECD), and fundoscopy were examined. A multivariable analysis was performed to determine the factors independently associated with 1-month postoperative vaulting. Results Fifty-one patients (102 eyes) were included. Compared with the eyes with normal vaulting, those with high vaulting had higher preoperative diopter values (P = 0.039), lower preoperative corrected visual acuity (P = 0.006), lower preoperative IOP (P = 0.029), higher preoperative ACD (P = 0.004), lower preoperative CLR (P = 0.046), higher ICL spherical equivalent (P = 0.030), higher intraoperative vaulting (P < 0.001), and lower IOP at 1 month (P = 0.045). The multivariable analysis showed that the only factor independently associated with high vaulting at 1 month after surgery was the intraoperative vaulting value (odds ratio = 1.005, 95% confidence interval: 1.002–1.007, P < 0.001). The intraoperative and 1-month postoperative vaulting values were positively correlated (R2 = 0.562). Conclusions The RESCAN700 system can be used to perform intraoperative optical coherence tomography to predict the vaulting value of ICL at 1 month.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Xu Chen ◽  
Yi Shao ◽  
Shi-Nan Wu ◽  
Shan-Bi Zhou

Objective. To observe the morphological changes and abnormal structure of corneal endothelial cells in children with uveitis, to analyze the related factors affecting the morphological changes of corneal endothelial cells, and to explore the clinical application of a corneal endothelial microscope in children with uveitis. Methods. The corneal endothelial cells of 70 patients with uveitis were photographed with the Topcon SP-3000 noncontact corneal endothelial microscope, and the corneal endothelial cell density (CD), average cell area (AVE), coefficient of variation of the cell area (CV), and percentage of hexagonal cells (PHC) were measured with the IMAGEnet system. Twenty-eight patients (56 eyes) with monocular uveitis were selected, with the affected eyes (28 eyes) as the experimental group and the contralateral healthy eyes (28 eyes) as the control group. The corneal endothelial cell parameters between the two groups were statistically analyzed. The parameters of corneal endothelial cells in 70 children with uveitis were compared, and the effects of the course of the disease, inflammatory cells in the anterior chamber, and posterior corneal deposition (KP) on the parameters of corneal endothelial cells were analyzed. Results. There are four abnormal forms of the corneal endothelium in children with uveitis: enlarged cell area gap, irregular cell shape, blurred intercellular space, and cell loss. KP showed irregular high reflective white spots in the corneal endothelial microscope images, surrounded by dark areas, and existed in all the eyes with dusty KP found in slit lamp examination and a small number of eyes without obvious KP. Comparing the corneal endothelial cell parameters between the experimental group and the control group, it was found that the corneal endothelial CD and PHC of the former were lower than those of the latter, and the difference was statistically significant ( P < 0.001 and P = 0.018 , respectively). The AVE and CA of the former were higher than those of the latter ( P = 0.013 and P = 0.046 , respectively). The corneal endothelial cell density of the eyes with a course of the disease of more than 1 year was lower than that of the eyes with a course of the disease less than 1 year, the coefficient of variation of the corneal endothelial cell area of the eyes with KP was higher than that of the eyes without KP, and the difference was statistically significant ( P = 0.003 and P = 0.030 , respectively). Conclusion. Corneal endothelial microscopy is one of the important methods for the detection of uveitis with high sensitivity. The change of morphological parameters of corneal endothelial cells is one of the important indexes to assist in the diagnosis of uveitis and can be further promoted in ophthalmological examination.


2021 ◽  
Vol 15 (1) ◽  
pp. 258-263
Author(s):  
Atul Kamath ◽  
Aditi Pai ◽  
Jagadeesh K. Reddy

Background: Nocardia is a common cause of endophthalmitis in southern India. It is an aggressive disease with a poor prognosis. Objective: This study was conducted using an amikacin antibiotic in the drip irrigation of balanced saline solution (BSS) during the surgery to prophylactically study the occurrence of Nocardia endophthalmitis and any subsequent toxic effects of the antibiotics used. Methods: Prospective study period was of 6 months, starting from July to December-2018. Preoperative and postoperative specular counts and macular thickness using Ocular Coherence Tomography (OCT) were compared with any incidence of Nocardia endophthalmitis. A total of 500 patients operated for manual SICS were randomly assigned into 2 groups. The first group of 250 patients received antibiotic amikacin added to the Balanced Saline Solution (BSS) irrigating solution throughout the course of the surgery. The second control group received no antibiotics. Manual SICS was performed on all 500 patients by a single surgeon and was found to be uneventful. Pre- and postoperative corneal endothelial cell density and mean macular thickness using OCT were taken and recorded of all the patients, respectively, and data obtained were statistically compared. Results: No incidence of Nocardia endophthalmitis among the cataract surgeries operated was found. There was no drug-related toxicity to the cornea or macula. Furthermore, no incidence of Nocardia endophthalmitis has been reported since 2018 after using antibiotics. Conclusion: A simple routine of adding amikacin in the drip prophylactically during the course of surgery helped us prevent Nocardia endophthalmitis with no side effects. Also, it will be an innovative technique that is economically feasible and effective in regions where Nocardia endophthalmitis is prevalent.


2021 ◽  
Vol 8 ◽  
Author(s):  
Zhe Zhang ◽  
Lingling Niu ◽  
Jing Zhao ◽  
Huamao Miao ◽  
Zhuoyi Chen ◽  
...  

Purpose: To compare the safety of the non-ophthalmic viscosurgical device (OVD) technique with that of the minimum OVD technique in EVO Implantable Collamer Lens (EVO-ICL) implantation.Methods: A total of 180 eyes of 90 consecutive patients were enrolled in the study, of which 100 eyes of 50 patients were treated with non-OVD technique, with a 55% success rate. The remaining 80 eyes of 40 patients were treated with min-OVD technique, so they were classified into the min-OVD group. Preoperative and postoperative intraocular pressure (IOP) measurements were collected and analyzed at 1, 2, 3, and 24 h. Visual acuity, corneal endothelial cell density (ECD), and corneal densitometry 24 h postoperatively were evaluated.Results: No significant difference was found in visual outcomes (P = 0.54) or ECD (P = 0.78) between the two groups. The operation time was significantly shorter in the non-OVD group (P &lt; 0.0001). The IOP was significantly higher at 1 h (P &lt; 0.0001), 2 h (P &lt; 0.0001) and 3 h (P = 0.0045) postoperatively in the min-OVD group. The non-OVD group had significantly lower IOP than the min-OVD group at 1 h (P = 0.01) and 2 h (P = 0.013) postoperatively. The temporal corneal densitometry in the non-OVD group were significantly lower than those in the minimum group (P = 0.0063) 1 day after surgery.Conclusion: The non-OVD technique is safe and efficient for ICL implantation. It can be a safer method of ICL implantation in that it completely eliminates ophthalmic viscoelastic devices related complications without causing additional complications in short term.


Sign in / Sign up

Export Citation Format

Share Document