Long-Term Follow Up of Atrioventricular Block in Transcatheter Aortic Valve Implantation

2011 ◽  
Vol 107 (4) ◽  
pp. 641-642 ◽  
Author(s):  
José Rubín ◽  
Pablo Avanzas ◽  
Raquel del Valle ◽  
Cesar Morís
2020 ◽  
Vol 125 (8) ◽  
pp. 1209-1215 ◽  
Author(s):  
Nicola Corcione ◽  
Giuseppe Biondi-Zoccai ◽  
Paolo Ferraro ◽  
Alberto Morello ◽  
Sirio Conte ◽  
...  

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
T J Carvalho Mendonca ◽  
L Patricio ◽  
M Oliveira ◽  
I Rodrigues ◽  
G Portugal ◽  
...  

Abstract Introduction Transcatheter aortic valve implantation (TAVI) is an established treatment in patients (P) with aortic stenosis. Despite the continuous developments of this procedure, high-grade conduction disturbances requiring permanent pacemaker (PPM) implantation is still a major and common complication of TAVI. Furthermore, long-term chronic right ventricular pacing has been associated with negative effects on ventricular function and heart failure (HF). Aim   to evaluate the long-term impact of PPM after TAVI focusing on mortality and HF hospitalization. Methods  We retrospectively examined P who underwent TAVI with a self-expanding valve from 2009 to 2018 at our institution. All P had pre-procedural clinical evaluation, including ECG, cardiac computed tomographic angiography and transthoracic echocardiography. P with previous PPM were excluded. Results  265P (57% male, mean age 81.4 years, 20% with left ventricular ejection fraction <40%) were analysed. Mean STS score and mean Euroscore II were 6.33% and 7.07%, respectively. Mean transvalvular gradient was 52.78 mmHg and mean aortic valve area 0.67 cm2. Forty-seven P (17%) underwent PPM implantation during the first 30 days after TAVI. P requiring PPM had higher prevalence of diabetes mellitus, chronic renal disease, atrial fibrillation and right bundle branch block. During a mean follow-up of 20.3 months, post-TAVI PPM was associated with similar mortality rate (29.8% vs. 25.6%, HR 1.28, 95% CI 0.72-2.29, p = 0.42) and similar cardiovascular mortality (9.8% vs. 6.4%, HR 0.72, 95% CI 0.21-2.4, p = 0.59) compared to P without PPM. There were no significant differences in HF hospitalization (4.9% vs. 2.4%, p = 0.47). Kaplan-Meier curves of total mortality and cardiovascular mortality according to the need for PPM post-TAVI were similar.  Conclusions  In P submitted to TAVI, PPM implantation is a relatively common finding, not associated with higher risk of total mortality, cardiovascular mortality or HF hospitalization in a long-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document