Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures

2016 ◽  
Vol 117 (5) ◽  
pp. 834-838 ◽  
Author(s):  
Michael Lauterbach ◽  
Karl Eugen Hauptmann
2016 ◽  
Vol 118 (3) ◽  
pp. 353-356 ◽  
Author(s):  
Mirlind Kastrati ◽  
Lukas Langenbrink ◽  
Michal Piatkowski ◽  
Jochen Michaelsen ◽  
Doris Reimann ◽  
...  

2013 ◽  
Vol 55 (11) ◽  
pp. 1365-1372 ◽  
Author(s):  
Michael Söderman ◽  
Maria Mauti ◽  
Sjirk Boon ◽  
Artur Omar ◽  
María Marteinsdóttir ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Haj Abdo ◽  
L Langenbrink ◽  
J Michaelsen ◽  
M Wirtz ◽  
E Altiok ◽  
...  

Abstract Objectives This study sought to evaluate the impact of tube angulation on radiation dose using image noise reduction technology in a clinical setting. Image noise reduction technology has been shown to significantly reduce radiation dose in coronary angiography in particular by reduction of radiation in cine mode. Methods In 500 coronary angiograms performed by the same operator the dose-area product (DAP) was determined. The DAP was determined for the cine mode as well as for the fluoroscopy mode. Furthermore, in the cine mode, the DAP on a per image (DAP/frame) basis was determined for the posterior-anterior projection (PA) as well as a left anterior oblique (LAO) cranial (LAO 20°/20°) and caudal (LAO 45°/−20°), right anterior oblique (RAO) cranial (RAO 20°/20°) and caudal (RAO 30°/−20°) angulations. The image intensifier area was kept constant for all angulations. Results Mean body mass index was 28.6±5.5 kg/m2. Mean total DAP was 1227±1417 cGy cm2. The mean ratio of DAP in cine mode/DAP in fluoro mode was 0.54±0.32. Mean DAP/frame in PA angulation was 5.5±3.3 (cGy cm2). Considering the cine mode, for the LAO cranial and LAO caudal angulations, the relative DAP/ frame compared to the PA angulation was 2.8±1.8 and 4.2±1.6, respectively. For the RAO cranial and RAO caudal angulations, the relative DAP/frame compared to the PA angulation was 1.7±2.2 and 1.8±1.4. Conclusions Using image noise reduction technology, radiation during fluoroscopy mode contributes more to total radiation dose than radiation during cine mode. In cine mode, the PA angulation has least radiation/ frame. The LAO caudal angulation is associated with greatest increase in radiation dose compared to the PA angulation, while LAO cranial angulation and RAO cranial and caudal angulations increase radiation dose to a lesser extent. Funding Acknowledgement Type of funding source: None


Radiology ◽  
2013 ◽  
Vol 269 (2) ◽  
pp. 553-560 ◽  
Author(s):  
Michael Söderman ◽  
Staffan Holmin ◽  
Tommy Andersson ◽  
Charlotta Palmgren ◽  
Draženko Babić ◽  
...  

2018 ◽  
Vol 12 (9) ◽  
pp. 1555-1559
Author(s):  
Yutan Wang ◽  
Yingpeng Dai ◽  
Xiangnan Liu ◽  
Bohan Liu ◽  
Xiaoyun Guo

2018 ◽  
Vol 78 (11) ◽  
pp. 15545-15573 ◽  
Author(s):  
Ali Abdullah Yahya ◽  
Jieqing Tan ◽  
Benyu Su ◽  
Kui Liu ◽  
Ali Naser Hadi

Sign in / Sign up

Export Citation Format

Share Document