patient radiation dose
Recently Published Documents


TOTAL DOCUMENTS

146
(FIVE YEARS 36)

H-INDEX

19
(FIVE YEARS 1)

2021 ◽  
Vol 94 (1126) ◽  
pp. 20210436 ◽  
Author(s):  
Beth A. Schueler ◽  
Kenneth A Fetterly

Data suggest that radiation-induced cataracts may form without a threshold and at low-radiation doses. Staff involved in interventional radiology and cardiology fluoroscopy-guided procedures have the potential to be exposed to radiation levels that may lead to eye lens injury and the occurrence of opacifications have been reported. Estimates of lens dose for various fluoroscopy procedures and predicted annual dosages have been provided in numerous publications. Available tools for eye lens radiation protection include accessory shields, drapes and glasses. While some tools are valuable, others provide limited protection to the eye. Reducing patient radiation dose will also reduce occupational exposure. Significant variability in reported dose measurements indicate dose levels are highly dependent on individual actions and exposure reduction is possible. Further follow-up studies of staff lens opacification are recommended along with eye lens dose measurements under current clinical practice conditions.


Atomic Energy ◽  
2021 ◽  
Author(s):  
A. G. Tsovyanov ◽  
A. G. Sivenkov ◽  
V. E. Zhuravleva ◽  
V. V. Kosterev

2021 ◽  
Vol Volume 14 ◽  
pp. 1807-1818
Author(s):  
Kelly S Wilson-Stewart ◽  
Davide Fontanarosa ◽  
Eva Malacova ◽  
Steven Gett ◽  
Allan Kruger ◽  
...  

2021 ◽  
Vol 94 (1123) ◽  
pp. 20210252
Author(s):  
Russell Oliver Kosik ◽  
Swee-Tian Quek ◽  
Elaine Kan ◽  
Shigeki Aoki ◽  
Chin Hua Yang ◽  
...  

Shielding, particularly of the gonads, has been a routine part of diagnostic radiographic imaging for many years. However, recent thinking suggests that such shielding may offer little benefit, and in some cases may actually cause harm, e.g. by obscuring anatomy or paradoxically increasing patient radiation dose secondary to the need for repeat imaging. This thinking has led many institutions in the West to abandon routine shielding. However, in Asia, shielding is still commonplace. It was felt that the Asia-Pacific Forum on Quality and Safety in Medical Imaging (APQS) was an ideal place to discuss the merits of shielding and deliver a pan-Asian consensus. The APQS is an annual meeting that convenes radiation safety and imaging quality experts from all of the major Asian regions. During the 2020 APQS meeting, radiation safety experts from each region discussed their opinions of shielding during a dedicated session. These experts’ views were mostly in line with the views of Western radiologists. However, important country specific and cultural factors were noted by each of the experts. A pan-Asian consensus was issued by the forum. It is hoped that this consensus will guide the development of future shielding policies throughout Asia.


2021 ◽  
Vol 29 (1) ◽  
Author(s):  
Klaus Doktor ◽  
Maria Lind Vilholm ◽  
Aldis Hardardóttir ◽  
Henrik Wulff Christensen ◽  
Jens Lauritsen

Abstract Background The Commission of the European Communities (CEC) has published: European Guidelines on Quality Criteria for Diagnostic Radiographic Images. These guidelines are considered a gold standard, recommended for use in quality assurance protocols. The objectives of this study: 1) Propose a graded classification format for Danish chiropractic clinics according to the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. 2) Propose a reporting principle for quality of radiographic images. 3) Document variation in radiation exposure among clinics. Methods This is a cross-sectional study of image quality based on random sampling from 148 chiropractic clinics. Clinics were included if using: 1) Digital radiography and 2) The chiropractic picture and archiving system (KirPACS) at the Nordic Institute of Chiropractic and Clinical Biomechanics (NIKKB) in Denmark. A sample of 296 lumbar spine series were randomly collected from KirPACS (January 2018). Two independent observers reviewed 50 lumbar spine series twice with a 4-week interval, testing intra- and inter-observer reproducibility. The same observers then reviewed the remaining 246 radiographic studies. All studies were evaluated using the CEC Quality Criteria. Patient radiation dose values were retrieved from KirPACS (First quarter of 2020). Results A reporting and classification principle of diagnostic image quality was used in 148 chiropractic clinics. Compliance with the 22 CEC Quality Criteria had proportions ranging from 0.72–0.96 for 18 criteria, while 4 criteria specifying detail and definition ranged between 0.20–0.66. The proposed rating system (A to E) revealed: 18 A clinics, 28 B clinics, 32 C clinics, 25 D clinics and 45 E clinics (A = highest quality; E = lowest quality). The patient radiation reference dose in Denmark is 7 mGy for the AP/PA lumbar spine. Very few clinics exceed the reference dose value, approximately 50% of clinics were below 5 mGy. Conclusion A reporting principle is proposed for a graded classification format based on the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. The Quality Criteria are for the most part met satisfactorily in 148 Danish chiropractic clinics, but important image details are compromised, in most cases, because of low patient radiation doses. The results of a patient radiation dose survey enabled documentation of variation in radiation exposure among chiropractic clinics.


2021 ◽  
pp. 20210406
Author(s):  
Jarrel Seah ◽  
Zoe Brady ◽  
Kyle Ewert ◽  
Meng Law

Artificial Intelligence (AI), including deep learning, is currently revolutionising the field of medical imaging, with far reaching implications for almost every facet of diagnostic imaging, including patient radiation safety. This paper introduces basic concepts in deep learning and provides an overview of its recent history and its application in tomographic reconstruction as well as other applications in medical imaging to reduce patient radiation dose, as well as a brief description of previous tomographic reconstruction techniques. This review also describes the commonly used deep learning techniques as applied to tomographic reconstruction and draws parallels to current reconstruction techniques. Finally, this paper reviews some of the estimated dose reductions in computed tomography (CT) and positron emission tomography (PET) in the recent literature enabled by deep learning, as well as some of the potential problems that may be encountered such as the obscuration of pathology, and highlights the need for additional clinical reader studies from the imaging community.


2021 ◽  
Vol 85 ◽  
pp. 192-199
Author(s):  
Julia Rousseau ◽  
Serge Dreuil ◽  
Céline Bassinet ◽  
Sophie Cao ◽  
Hélène Elleaume

2021 ◽  
Author(s):  
Klaus Knarberg Doktor ◽  
Maria Lind Vilholm ◽  
Aldis Hardardóttir ◽  
Henrik Wulff Christensen ◽  
Jens Lauritsen

Abstract BackgroundThe Commission of the European Communities (CEC) has published: European Guidelines on Quality Criteria for Diagnostic Radiographic Images. These guidelines are considered a gold standard, recommended for use in quality assurance protocols. The objectives of this study: 1) Propose a graded classification format for Danish chiropractic clinics according to the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. 2) Propose a reporting principle for quality of radiographic images. 3) Document variation in radiation exposure among clinics.MethodsThis is a cross-sectional study of image quality based on random sampling from 148 chiropractic clinics. Clinics were included if using: 1) Digital radiography and 2) The chiropractic picture and achieving system(KirPACS) at the Nordic Institute of Chiropractic and Clinical Biomechanics(NIKKB) in Denmark. A sample of 296 lumbar spine series were randomly collected from KirPACS. Two independent observers reviewed 50 lumbar spine series twice with a 4-week interval, testing intra- and inter-observer reproducibility. The same observers then reviewed the remaining 246 radiographic studies. All studies were evaluated up against the CEC Quality Criteria. Patient radiation dose values were retrieved from KirPACS. ResultsA reporting and classification principle of diagnostic image quality was used in 148 chiropractic clinics. Compliance with the 22 CEC Quality Criteria had proportions ranging from 0.72-0.96 for 18 criteria, while 4 criteria specifying detail and definition ranged between 0.20-0.66. The proposed rating system (A to E) revealed: 18 A clinics, 28 B clinics, 32 C clinics, 25 D clinics and 45 E clinics (A = highest quality; E= lowest quality). The patient radiation reference dose in Denmark is 7 mGy for the AP/PA lumbar spine. Very few clinics exceed the reference dose value, approximately 50 % of clinics were below 5 mGy.ConclusionA reporting principle is proposed for a graded classification format based on the CEC-quality criteria for diagnostic radiographic images of the lumbar spine. The Quality Criteria are for the most part met satisfactory in 148 Danish chiropractic clinics, but important image details are compromised, in most cases, because of low patient radiation doses. The results of a patient radiation dose survey enabled documentation of variation in radiation exposure among chiropractic clinics.